background image

INSTRUCTION MANUAL 

 

GB

 

– 

5/6

 

www.stifnet.com

 - DOC NO. BE0455020-A

 

 
 

After the detection distance learning operation, you should check that the VIGIBELT® CDM80 is in mode "1" 
in normal operation and in mode "2" in the presence of a metal target (see LED status below). 

 

 
 

Remove the adjustment tool and reposition the CDM80 on the opening, tighten the four M6 locknuts with 
type L washers (clamping torque 4N.m) according to diagram E. Now it is put into operation. 

 
 

 
 
 

Note: to make another adjustment, it is necessary to reset each detector by following the instructions 
below, then resume steps 1 and 2 of the programming.

 

 

-  Disassemble the CDM80 from the sheath to remove it from any metal mass. 
-  Press and hold the detector button, it turns off the green diode for 3 seconds, then it turns on for 4 seconds, 

then turns off again. Release the button 

-  The detector is now without a resident program. You can resume the detection distance learning operation. 

 
 

 

1_Normal operation: 

 

GREEN DIODE ON AND ORANGE ON (contact closed) 

2_Object in the detection field:  GREEN DIODE ON AND ORANGE Off (open contact) 
3_Electrical fault:   

 

NO DIODE LIT 

 

Led observation 
window during sensor 
setting 

 

Return the access screw 
to the learn button 

Figure E 

3s 

4s 


Flashes 

RESET OK 