INSTALLATION
- Following figure A, make two symmetrical openings on each side of the elevator (square opening of 112mm + 4
holes on Ø6.5 on a square of 126mm)
Target EAZY>DETEC
X
s
Ji
Ep
Opening
112mm
4 holes Ø6.5 on
126mm
200
Lift
S
he
a
th
Ep. = thickness of the sheath
Ji = clearance between the inside of the sheath and
the strap
S = thickness of the strap
TARGET
BUCKET
POSITION OF THE OPENING
L90 - H80
X = Ep. + Ji + S + 60
L150 - H110
X = Ep. + Ji + S + 75
Figure A
Careful: obligation to install an EAZY> DETEC
metal bucket every 30 meters of belt on
elevators equipped with plastic or stainless-
steel buckets
Target EAZY>DETEC