INSTALLATION 

 
- Following figure A, make two symmetrical openings on each side of the elevator (square opening of 112mm + 4 
holes on Ø6.5 on a square of 126mm) 
 

 

 

Target EAZY>DETEC 

 

Ji 

Ep 

Opening  

 112mm 

4 holes Ø6.5 on 

 126mm 

200

 

Lift

 S

he

a

th

 

Ep. = thickness of the sheath 

 

Ji = clearance between the inside of the sheath and 
the strap 

 

S = thickness of the strap 

TARGET 
BUCKET 

POSITION OF THE OPENING 

L90 - H80 

X = Ep. + Ji + S + 60 

L150 - H110 

X = Ep. + Ji + S + 75 

 

Figure A 

 

Careful: obligation to install an EAZY> DETEC 
metal bucket every 30 meters of belt on 
elevators equipped with plastic or stainless-
steel buckets 

Target EAZY>DETEC 