background image

ENGL

IS

H

iNSTallaTiON 

PrOFi SElECT modular system

WSP-2-DUO, WSG-2-DUO 

| 5

8.1  Base station

Base stations are fully functional apartment modules which 

can be further equipped with output modules and installation 

options.

Designation

Description

WSP-2-DUO 

Copper-soldered heat exchanger, 

integral instantaneous water heater

WSG-2-DUO 

Stainless steel-soldered heat exchanger, 

integral instantaneous water heater

D

00000

75

08

6

1

4

3

2

5

6

10

11

12

9

7

8

1  air vent screw

2  Mounting position on finished walls

3  Mounting position on unfinished walls

4  room heating valve

5  Differential pressure controller

6  Heat meter adaptor

7  Equipotential bonding connection

8  Pressure surge reducer

9  instantaneous water heater

10 Plate heat exchanger

11 Dirt filter with strainer

12 "Thermo Fluid System" (TFS) temperature controller

 

Note

There are no output modules available for the WSP-2-

DUO and WSG-2-DUO base stations.

8.1.1  Heat meter 

Heat meters must be installed in the unit on site.
The base units are equipped with appropriate fittings (110 mm, 

¾” 1.5 m³/h) for the heat meters.
Sensor retainer: 

 - Directly immersed 
 - Sensor length: 28 mm 
 - Diameter: Max. 5.4 mm; at the sealing point min. 5.2 mm

8.1.2  Heat exchanger operating conditions

The threaded, stainless steel soldered heat exchanger is par-

ticularly suitable for applications where water quality is critical.

Water constituents / 

characteristic values

Unit 

Heat exchanger 

copper soldered

Heat exchanger 

stainless steel sol-

dered

pH value 

 

7-9 (taking Si index 

into account)

6-10 

Saturation index Si 

(delta pH value)

 

-0.2 < 0 < +0.2 

Not specified 

Total hardness

°dH

6-15

6-15

Conductivity

μS/cm 10...500

Not specified

Suspended solids

mg/l

< 30

< 30

Chloride

mg/l

above 100 °C no chlorides permissible

Free chlorine

mg/l

< 0.5

< 0.5

Hydrogen sulphide

mg/l

< 0.05

Not specified

ammonia

mg/l

< 2

Not specified

Sulphate

mg/l

< 100

< 400

Hydrogen carbonate

mg/l

< 300

Not specified

Hydrogen carbonate/

sulphate

mg/l 

> 0.1 

Not specified 

Sulphide

mg/l

< 1

< 7

Nitrate

mg/l

< 100

Not specified

Nitrite

mg/l

< 0.1

Not specified

iron, dissolved

mg/l

< 0.2

< 0.2

Manganese

mg/l

< 0.1

Not specified

Free, aggressive carbon 

dioxide

mg/l 

< 20 

Not specified 

 

Note

We recommend using a softening system if the total 

hardness is > 15 °dH.

8.1.3  Thermal overflow valve operating conditions

a thermal overflow valve can be used at the end of the line to 

increase comfort levels.

Designation

Part number

Overflow valve

ÜVS

236016

 

Note

if the simple pipe length (see following table) of the 

last heat interface unit in the line is not exceeded, a 

thermal overflow valve is not required.

Required flow temperature [°C]

70

65

60

55

Nominal pipe diameter

Pipe length [m]

DN 15

21

17

12

7

DN 20

18

15

11

6

DN 25

16

13

9

5

DN 32

14

11

8

5

DN 40

13

10

7

4

DN 50

11

9

7

4

Summary of Contents for WSG-2-DUO

Page 1: ...OPERATION AND INSTALLATION PROFI SELECT apartment module for DHW and heating with integral instantaneous water heater WSP 2 DUO WSG 2 DUO...

Page 2: ...sions and connections 15 16 2 Wiring diagrams 18 16 3 Data tables 22 GUARANTEE ENVIRONMENT AND RECYCLING OPERATION 1 General information These instructions are intended for qualified contractors Note...

Page 3: ...ies or a lack of experience and know how provided that they are supervised or they have been instructed on how to use the ap pliance safely and have understood the potential risks Children must never...

Page 4: ...ion is channelled through the heat exchanger and heated as required DHW flows from the heat exchanger to the DHW outlet The temperature level of the DHW can be further increased by switching on the in...

Page 5: ...changer is par ticularly suitable for applications where water quality is critical Water constituents characteristic values Unit Heat exchanger copper soldered Heat exchanger stainless steel sol dered...

Page 6: ...al lation Specification 1 1 Heating circuit with mixer thermostatically controlled E1 HKT Heating circuit with mixer with high efficiency pump including pipework in the base station D0000074998 The fl...

Page 7: ...the heating circuit distributor according to the design engineer s specifications f f Do not draw off any DHW while testing the heating water flow rate Make sure that all thermostatic valves and un de...

Page 8: ...s Z3 GUL DUO Casing for unfinished walls long for DUO stations Mounting rail Z5 MS 7 Mounting rail Z5 MS 9 Mounting rail Heating circuit distributor Z6 HKV 4 DUO Heating circuit distributor for DUO st...

Page 9: ...In place of the prefitted protective caps actuators can be at tached directly to the integral valves Example HKV 9 DUO D0000075054 10 Controller terminal strip Z10 RKL 10 1 Controller terminal strip...

Page 10: ...075188 9 1 3 For installation on unfinished walls Lines routed from below D0000075198 Lines routed from behind D0000075199 9 2 Storage f f Store the appliance in a dry location in its original packagi...

Page 11: ...Alternatively you can retrofit the appliance To elim inate contamination or other problems associated with construction sites it is sufficient to install only the mounting rail or heating circuit dist...

Page 12: ...part of the standard delivery If setting the casing for unfinished walls into a drywall the fixing tabs of the casing can be used as installation aids f f Align the casing D0000075190 f f Guide the ap...

Page 13: ...ion Protect the electronics of the integral instantaneous water heater from escaping water f f Fill and vent the central heating system according to the heat generator operating and installation instr...

Page 14: ...ilter f f Visually inspect the appliance for leaks Completing maintenance work f f Open the shut off valves required for operation f f Check the condition of the appliance and clean off any external d...

Page 15: ...4 Cold water outlet Male thread G 3 4 G 3 4 c06 DHW outlet Male thread G 3 4 G 3 4 d33 Heat source flow Male thread G 3 4 G 3 4 d34 Heat source return Male thread G 3 4 G 3 4 e01 Heating flow Male thr...

Page 16: ...ng circuit with mixer thermostatically controlled E1 HKT 2 Heating circuit without mixer E2 HKU c01 e31 e02 d33 c06 c04 e01 d34 e30 733 17 675 630 788 210 274 336 402 467 531 596 628 662 43 110 176 D0...

Page 17: ...3 GAK DUO 735 850 180 D0000075038 3 10 Casing for unfinished walls short Z3 GUK DUO 780 880 740 920 880 880 180 205 D0000075050 3 11 Casing for finished walls long Z3 GAL DUO 735 1400 180 D0000075037...

Page 18: ...1 N A CO HZ 8 L1 N A CO HZ 9 L1 N A CO HZ 10 L1 N A CO L1 STA 1 N L1 N L1 N L1 L2 L1 L2 230V 24V L1 N STA 2 L1 N STA 3 L1 N STA 3 L1 N STA 5 L1 N STA 6 L1 N STA 7 L1 N STA 8 L1 STA 9 N L1 N STA 10 L1...

Page 19: ...zur Weitergabe des Au enf hlers SEHC Mischer AUF Mischer ZU Heizkreispumpe IP20 S5 5 S4 4 S3 3 S2 2 S1 1 Au enf hler R cklauff hler Heizung Vorlauff hler Heizung PT 1000 L L R1 L L R3 R2 Power PE N N...

Page 20: ...L1 HZ 1 L1 N A CO HZ 2 L1 N A CO HZ 3 L1 N A CO HZ 4 L1 N A CO HZ 5 L1 N A CO HZ 6 L1 N A CO HZ 7 L1 N A CO HZ 8 L1 N A CO HZ 9 L1 N A CO HZ 10 L1 N A CO L1 STA 1 N L1 N L1 N L1 L2 L1 L2 230V 24V L1...

Page 21: ...ENGLISH Installation Specification WSP 2 DUO WSG 2 DUO 21 Contact thermostat E9 ATR N PE L 230 V 16A N L1 AB A AB A 1 3 2 4 5 6 7 Tw E9 Anlegetemperaturregler D0000080393...

Page 22: ...Design temperature on the primary side C 43 43 Electrical data Output on the DHW side without instantaneous water heater kW 31 31 Instantaneous water heater rated output kW 11 11 Instantaneous water...

Page 23: ...16 15 15 60 kg h primary 692 954 1102 681 936 1080 WSP 2 DUO WSG 2 DUO Flow temperature C 43 43 43 DHW temperature C 38 38 38 Cold water temp C 6 7 8 DHW l min l min 7 9 10 12 13 16 7 9 10 12 13 16 7...

Page 24: ...differential pressure m h 2 0 Circulation pump type Yonos Para RS 15 6 Suitable for WSP 1 WSP 3 WSG 1 WSG 3 2 Heating circuit without mixer E2 HKU E2 HKU 234669 Suitable for WSP 1 WSP 3 WSG 1 WSG 3 M...

Page 25: ...e subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquired in...

Page 26: ...26 WSP 2 DUO WSG 2 DUO NOTES...

Page 27: ...ENGLISH WSP 2 DUO WSG 2 DUO 27 NOTES...

Page 28: ...n en technische wijzigingen Salvo error o modificaci n t cnica R tt till misstag och tekniska ndringar f rbeh lls Excepto erro ou altera o t cnica Zastrze one zmiany techniczne i ewentualne b dy Omyly...

Reviews: