iNSTallaTiON
PrOFi SElECT modular system
WSP-2-DUO, WSG-2-DUO
| 7
[1.2]
Heating circuit with mixer, electrically controlled |
E1-HKE
incl.
SEHC/SEHCM Control unit operating instructions
Heating circuit with mixer with high efficiency pump including
pipework in the base station
D
00000
74
99
9
The flow temperature is controlled by an injection system using
an electric 3-point actuator and a 2-way straight-through valve.
f
f
Observe the enclosed instructions.
Checking / correcting the heating water flow rate
f
f
Ensure heat supply through the central heat generator.
The flow temperature should have reached the design
value for the network.
f
f
Switch on the pump.
f
f
Perform hydronic balancing of the underfloor heating
circuit at the heating circuit distributor according to the
design engineer's specifications.
f
f
Do not draw off any DHW while testing the heating water
flow rate. Make sure that all thermostatic valves and un-
derfloor heating control valves are fully open.
f
f
after balancing is complete, check the set flow tempera-
ture again.
[2]
Heating circuit without mixer | E2-HKU
Heating circuit connection inclusive of pipework in the base
station for connecting to a heating circuit without mixer, e.g.
radiators.
Shut-off valves and a zone valve for manual adjustment of the
heating circuit are integrated. Optional installation of an actu-
ator on the valve is possible.
D
00000
75
000
[7.1]
Pipework thermal insulation | E7-WDR-1
[7.2]
Pipework thermal insulation | E7-WDR-2
Thermal insulation for the pipework in the apartment module,
made of highly flexible insulation material with high resistance
to water vapour diffusion and low thermal conductivity