16. Specification
16.1 Dimensions and connections
Note
Depending on the range of functions, a mounting rail
or heating circuit distributor will be required to con-
nect the base station.
f
f
The screw connection torque of the mounting rail
or the heating circuit distributor should be 35 Nm.
WSP-2-DUO for DHW and heating circuit without mixer
c01
e02
d33
c06
c04
e01
d34
733
17
675
630
788
210
274
336
467
531
596
662
43
176
D
00000
74
99
7
WSP-2-DUO WSG-2-DUO
c01 Cold water inlet
Male thread
G 3/4
G 3/4
c04 Cold water outlet
Male thread
G 3/4
G 3/4
c06 DHW outlet
Male thread
G 3/4
G 3/4
d33 Heat source flow
Male thread
G 3/4
G 3/4
d34 Heat source return
Male thread
G 3/4
G 3/4
e01 Heating flow
Male thread
G 3/4
G 3/4
e02 Heating return
Male thread
G 3/4
G 3/4
WSP-2-DUO for DHW and heating circuit with mixer
[1.1]
Heating circuit with mixer, thermostatically
controlled |
E1-HKT
c01
e31
d33
c06
c04
d34
e30
733
17
675
630
788
210
274
336
467
531
596
662
43
176
D
00000
75
07
4
WSP-2-DUO/HKT
c01 Cold water inlet
Male thread
G 3/4
c04 Cold water outlet
Male thread
G 3/4
c06 DHW outlet
Male thread
G 3/4
d33 Heat source flow
Male thread
G 3/4
d34 Heat source return
Male thread
G 3/4
e30 Heating flow, mixed
Male thread
G 3/4
e31 Heating return, mixed
Male thread
G 3/4