iNSTallaTiON
Specification
22 |
WSP-2-DUO, WSG-2-DUO
16.3 Data tables
WSP-2-DUO | WSG-2-DUO
WSP-2-DUO
WSG-2-DUO
238133
238134
Hydraulic data
Output on the primary side
kW
31
31
Max. flow rate on primary side, incl. differential pressure controller
and heat meter at dp = 600 hPa
l/h
1300
1300
Output on the secondary side (at 10 K)
kW
12
12
Draw-off rate at secondary 10/48 °C
l/min
14.5
14.5
Draw-off rate at secondary 10/38 °C
l/min
16
16
Draw-off rate at secondary 38/60 °C
l/min
7
7
Draw-off rate at secondary 38/44 °C
l/min
16
16
Max. flow rate on the secondary side, at 100 hPa differential pressure
l/h
1000
1000
Pressure drop on the DHW side without flow limiter
hPa
1600
1600
Design temperature on the primary side
°C
43
43
Electrical data
Output on the DHW side without instantaneous water heater
kW
31
31
instantaneous water heater rated output
kW
11
11
instantaneous water heater rated voltage
V
400
400
instantaneous water heater phases
3/PE
3/PE
instantaneous water heater frequency
Hz
50
50
instantaneous water heater fuse protection
a
16
16
Application limits
application limit, conductivity, heat exchanger
μS/cm
< 500
> 500
Max. permissible temperature
°C
60
60
Max. permissible pressure
MPa
1.0
1.0
Max. DHW temperature in instantaneous water heating mode
°C
60
60
Versions
Material of plate heat exchanger
Stainless steel (copper-soldered)
Stainless steel (soldered)
iP rating
iP25
iP25
Connections
Connection
G 3/4
G 3/4
alignment of connections
Bottom
Bottom
Dimensions
Height
mm
780
780
Width
mm
735
735
Depth
mm
180
180
Weights
Weight
kg
32
32
Summary of Contents for WSG-2-DUO