![STIEBEL ELTRON WK 2 Installation Manual Download Page 5](http://html1.mh-extra.com/html/stiebel-eltron/wk-2/wk-2_installation-manual_1376898005.webp)
WK 2
| 5
ENGL
IS
H
INSTALLATION
Installation
Note
To prevent disturbance due to structure-borne noise
transmission, never install the wall mounting bracket
on the external walls of living areas or bedrooms.
f
f
Install the wall mounting bracket on a garage
wall, for example.
Note
To facilitate installation and maintenance work, we
recommend a maximum installed height of 1 m.
f
f
Mark out the positions of the holes to be drilled on the
wall. To do this, hold the wall mounting bracket against
the wall at the required installation height.
!
Material losses
Ensure that no cables/water pipes are damaged
through drilling the holes.
4. Installation
4.1 Securing the assembly to the wall
f
f
Drill the holes.
f
f
Insert rawl plugs into the holes.
f
f
Secure the wall mounting bracket to the wall.
!
Material losses
Ensure that the wall mounting bracket is flush with
the wall.
f
f
Check the wall mounting bracket is straight using a spirit
level.
f
f
If necessary, level the wall mounting bracket by loosening
and retightening the screws.
f
f
Tighten all the bolts securely with a spanner.
4.2 Securing the outdoor unit
26
_0
3_0
1_
15
48
Note
Lifting straps to transport the appliance can be hooked
into the area highlighted in grey at the bottom of the
support frame.
f
f
Undo the appliance feet from the outdoor unit. Dispose of
the appliance feet.
f
f
Screw the rubber buffers into the illustrated positions on
the outdoor unit.
D
00000
55
14
5
!
Material losses
Ensure that the outdoor unit does not slip from the
wall mounting bracket during installation.
f
f
Place the outdoor unit with its anti-vibration mounts onto
the wall mounting bracket.
f
f
Insert the screws with washers and retaining clips into the
rubber buffers. Ensure that the retaining clips are aligned
at right angles to the wall bracket.
f
f
Tighten all screws.
f
f
Attach the end caps to the ends of the wall mounting
bracket.
!
Material losses
Have a qualified contractor check the installation to
ensure that the appliance is permanently and securely
installed.
5. Specification
5.1 Data table
WK 2
234722
Support length
mm
800
Weight
kg
175
Suitable for
15/20/25 AC(S), HPA-O Premium