2. Installation instructions

 for the professional

2.1 Regulations and Requirements

y

 

This fitting must be installed, commissioned and maintained only by an approved specialist in accordance with these instructions.

y

 

Area of application: open (pressureless) instantaneous water heaters.

y

 

Rated up to 0.6 MPa flow pressure - at pressures above 0.6 MPa, a pressure reducing valve must be fitted in the main pipe.

Rinse the cold water supply pipe thoroughly.

2.2 Installation of MAE

Insert the fitting with sealing ring (

7

) in the 

washbasin and from below attach with U-
shaped washer (

8

), U-shaped thrust washer 

(

9

) and clamping sleeve (

10

).

2.2.1 Water  Connection

Connect the short connection hose marked 
„blue“ (

4

×

 blue ) to the angle valve - cold 

water supply pipe.
Connect the two connection hoses to the 
instantaneous water heater using union nuts 
and seals.
Screw the connection hose (

5

Ø

 blue) with 

the downward-pointing arrow to the inlet 
connector of the instantaneous water heater, 
and connection hose (

6

×

 red) with the up-

ward-pointing arrow to the outlet connector.

When fitting the connection hoses, note the 
following

 

A

 

(see page 3):

–  Do not bend hoses immediately after the 

joint; leave a straight section of at least 
15 mm;

–  Do not kink hoses but ensure a minimum 

curvature radius of 20 mm;

–  Avoid distortion during fitting;
–  Avoid tension during fitting;

–  Twisting during fitting is not permitted.

2.3 Fitting the Drain Unit

 

(

11

)

Unscrew the drain sleeve (

11.1

) from the tun-

dish (

11.4

) and from above push with the seal 

(

11.2

) through the drain opening in the wash-

basin and screw to the tundish applied below 
the washbasin with the shaped seal (

11.3

). 

Insert the two-piece pull rod in the fitting 
body, screw in place and connect to the drain 
unit using the hinge piece.

Technical Data 

Flow rate 

0.3 MPa =

^ 3.5 l/min

Test pressure 

1.6 MPa max.

Operating  
temperature 

90 °C max.

2.4 Installation of MAZ

Insert the fitting with sealing ring (

9

) in the 

washbasin and from below attach with U-
shaped washer (

11

), U-shaped thrust washer 

(

12

) and clamping sleeve (

13

).

2.4.1 Water  Connection

Connect the short connection hose marked 
„blue“ (

6

×

 blue ) to the angle valve - 

cold 

water supply pipe

.

Connect the two connection hoses to the 
instantaneous water heater using union nuts 
and seals.
Screw the connection hose (

7

Ø

 blue) with 

the downward-pointing arrow to the inlet 
connector of the instantaneous water heater, 
and connection hose (

8

×

 red) with the up-

ward-pointing arrow to the outlet connector.

When fitting the connection hoses, note the 
following

 

A

 

(see page 3):

–  Do not bend hoses immediately after the 

joint; leave a straight section of at least 
15 mm;

–  Do not kink hoses but ensure a minimum 

curvature radius of 20 mm;

–  Avoid distortion during fitting;
–  Avoid tension during fitting;
–  Twisting during fitting is not permitted.

Technical Data

Flow rate 

0.3 MPa =

^ 3.5 l/min

Test pressure 

1.6 MPa max.

Operating  
temperature 

90 °C max.

2.5 Installation of MAW

Screw the fitting with cover plate (

6

) into the 

wall plate.
Screw the swivel outlet (

5

) to the fitting body 

by turning the union nut.

Technical Data

Flow rate 

0.3 MPa =

^ 3.5 l/min

Test pressure 

1.6 MPa max.

Operating  
temperature 

90 °C max.

3. Environment and recycling

For guarantees please refer to the respecti-
ve terms and conditions of supply for your 
country.

Please help us to protect the environment by 
disposing of the packaging in accordance with 
the national regulations for waste processing.

The installation, electrical connection 
 

  -
ler.

The company does not accept liability 
for failure of any goods supplied which 
are not installed in accordance with the 
manufacturer‘s instructions.

4. Guarantree

Summary of Contents for MAE 185476

Page 1: ...ini Instantaneous Water Heater DNM Operating and Installation Instructions 3ROVNL UPDWXU GR EH FL QLHQLRZ FK SU HS ZRZ FK RJU HZDF ZRG 10 QVWUXNFMD REV XJL L PRQWD X rHVN H WODNRYt EDWHULH SUR PDOt SU...

Page 2: ...lation Instructions 9 2 1 Provisions and Regulations 2 2 Installation of MAE 2 3 Fitting the Drain Unit 2 4 Installation of MAZ 2 5 Installation of MAW 3 Environment and recycling 9 4 Guarantee 9 6SLV...

Page 3: ...10 max55 45 170 150 500 235 15 8995 01 8997 01 8999 01 8996 01 8998 01 9000 01 9002 01 MAE MAZ MAW Abmessungen Dimensions PLDU 5R PHUU Dimensiuni MAE MAZ Installationsbeispiele Example of Insatallati...

Page 4: ...mpl Bestell Nr 25 45 68 4 Anschlussschlauch KW blau 5 Anschlussschlauch 3 8 blau 6 Anschlussschlauch 3 8 rot 7 Dichtring 8 U Formscheibe 9 U Druckscheibe 10 Spannh lse SW 13 11 Ablaufgarnitur 11 1 Abl...

Page 5: ...1Vorschriften und Bestimmungen y Die Montage sowie die Erstinbetriebnahme und die Wartung dieser Armatur darf nur von einem zugelassenen Fachmann entsprechend dieser An weisung ausgef hrt werden y An...

Page 6: ...2 1 27 1 20 12 12 1 1 1 0 2 1 0 0 3 12 5 0 12 2 0 012 0 1 0 0 0 3 24 0 25 023 0 3 5 2 0 2 3 3 05 023 0 2 0 2 2 0 0 2 0 2 0 0 3 0 0 5 0 0 0 9 0 1 1612 5 0 6 3 2 0 2 0 00 2 3 3 5 2 73 2 1 2 2 12 5 0 1 5...

Page 7: ...3 09 A4 03 9 1 04 0490 0 0 0 F 0 1H3 09 C 7 09 0 07 C 1H3 09 A 420 20A0 3 07 0 0470 A0 09 9 0 4209 8 H 40 0 9 04 3A04 0 0 9 40 H 0 903809 A4 F8 74 30 0 4 7 9 9 206 09 A04 0 9 0 A0209 0 9 401 770 12 9...

Page 8: ...nection hose KW blue 5 Connection hose 3 8 blue 6 Connection hose 3 8 red 7 Sealing ring 8 U shaped washer 9 U shaped thrust washer 10 Clamping sleeve SW 13 11 Fitting the drain 11 1 Drain sleeve 11 2...

Page 9: ...d connect to the drain unit using the hinge piece Technical Data Flow rate 0 3 MPa 3 5 l min Test pressure 1 6 MPa max Operating temperature 90 C max 2 4 Installation of MAZ Insert the fitting with se...

Page 10: ...FLHS HM GR EDWHULL VWU D ND F HUZRQD SLHU FLH XV F HOQLDMmF SRGN DGND 8 SRGN DGND GRFLVNRZD 8 WXOHMD PRFXMmFD NOXF HVSR X RGS ZX ZRG XP ZDONL RGS Z XV F HOND XV F HOND NV WD WRZD V IRQ RGS ZX FL J R S...

Page 11: ...SROmF s SU HJXEHP HVSR X RGS ZX DQH WHFKQLF QH 3U HS Z 03D A O PLQ L QLHQLH SU EQH PDNV 03D 7HPSHUDWXUD SUDF PDNV 0RQWD DUPDWXU 0 UPDWXU ZUD SLHU FLHQLHP XV F HOQLDMmF P Z R s Z RWZ U Z XP ZDOFH L SU...

Page 12: ...FyVOR S LSRMRYDFy KDGLqND VWXGHQt YRG PRGUl S LSRMRYDFy KDGLqND PRGUl S LSRMRYDFy KDGLqND qHUYHQl W VQyFy NURX HN SRGOR ND 8 WYDUX RS UQl SRGOR ND 8 WYDUX XSyQDFy NROyN 1 Y WRNRYt VRXSUDY Y WRNRY NDOy...

Page 13: ...PLQ NX HEQy WODN PD 03D 3URYR Qy WHSORWD PD LYRWQy SURVW HGy D UHF NODFH lGlPH 9lV DE VWH QlP E OL QlSRPRFQL S L RFKUDQ LYRWQyKR SURVW HGy 3URWR RGVWUD WH REDO Y VRXODGX V SODWQ PL S HGSLV SUR SUDFRYl...

Page 14: ...racord 3 8 ro u 7 Arm tur etan are 8 aib ovalizat U 9 aiba presiune U 10 Bulonul central de arc SW 13 11 Garnitur evacuare 11 1 Cupa evacuare 11 2 Garnitur etan are 11 3 Garnitur etan are ovalizat 11...

Page 15: ...utorizat p n la o presiune curgere de 0 6 MPa la mai mult de 0 6 MPa trebuie integrat n conducta principal un ventil pentru reducerea presiunii Purja i bine conducta intrare ap rece 2 4 Montaj MAZ Int...

Page 16: ...3 8 1 A BC 2 8 1 9 3 D 5 1 2 8 1 9 3 BF 5 1 2 8 1 9 3 BF 5 1 8 8 B G5 9 1 H G5 9 1 I J C K 2 L 3 M 1 1 1 8 8 C N O3 N P4 Q N 5 O N P 25 4 R D 2 8 1 3 8 1 A C 1 2 8 1 9 3 D 5 1 2 8 1 9 3 BF 5 1 B 2 8 1...

Page 17: ...9 3 8 4 V I4 V W 4 N HI XY y V 4 1 0 3 8 8 y 8 3 1 3 C y 3 3 I4 V 5 I4 V 3 1 8 1 8 8 1 Z 25 8 8 8 9C 80 G5 1 1 9 1 C4 G5 1 1 9 1 C 1 C 0 1 O 1P 8 1 9 3 4 1C 3 0 T 1 0 8 9 3 3 0 80 3 2 8 1 9 3 1C 14 1...