background image

AWG 315-600 

 | 13

ENGL

IS

H

INSTALLATION 

Specification

5.1.4  AWG 315 L

479

477

476

95

280

500

625

422

422

314

D

00000

17

27

0

5.1.5  AWG 560 L

881

477

878

85

290

510

625

422

824

340

725

D

00000

17

27

1

5.1.6  AWG 600 L

649

647

95

260

400

525

592

646

550

D

00000

17

27

2

5.2  Minimum dimensions of the cellar duct 

(only for AWG L)

T

B

100

26

_0

3_

14

_0

11

2

AWG 315 L

AWG 560 L

AWG 600 L

B

Width

mm

600

1000

800

T

Depth

mm

600

600

600

5.3  Data table

 

 

AWG 315 GL AWG 560 H-GL AWG 560 V-GL

 

 

232955

232956

232957

Height

mm

490

490

894

Width

mm

483

897

483

Depth

mm

627

627

627

Weight

kg

12

19

19

Wall thickness

mm

280 - 500

280 - 500

280 - 500

Pressure drop at 

1000 m³/h

Pa 

16 

  

  

Pressure drop at 

3000 m³/h

Pa 

  

26 

24 

min. outlet ap-

erture

mm 

450x450 

830x430 

430x830 

max. air volume

m³/h

1500

3500

3500

colour

 

RAL 9006

RAL 9006

RAL 9006

 

 

AWG 315 SR AWG 560 H-SR AWG 560 V-SR

 

 

233836

233837

233838

Height

mm

490

490

894

Width

mm

483

897

483

Depth

mm

627

627

627

Weight

kg

12

19

19

Wall thickness

mm

280 - 500

280 - 500

280 - 500

Pressure drop at 

1000 m³/h

Pa 

16 

 

 

 

 

Pressure drop at 

3000 m³/h

Pa 

  

26 

24 

min. outlet ap-

erture

mm 

450x450 

830x430 

430x830 

max. air volume

m³/h

1500

3500

3500

colour

 

Silver metallic Silver metallic Silver metallic

 

 

AWG 315 L

AWG 560 L

AWG 600 L

 

 

231039

231041

231044

Height

mm

477

477

647

Width

mm

479

878

649

Depth

mm

625

625

525

Weight

kg

12

19

19

Wall thickness

mm

280 - 500

280 - 500

260 - 400

Pressure drop at 

1000 m³/h

Pa 

  

  

Pressure drop at 

3000 m³/h

Pa 

  

min. outlet ap-

erture

mm 

450x450 

830x430 

600x600 

max. air volume

m³/h

1500

3500

3500

colour 

 

 

Aluminium, 

anodised

Aluminium, 

anodised

Aluminium, 

anodised

Summary of Contents for AWG 315 GL

Page 1: ...ATION INSTALLAZIONE Wanddurchführung Wall outlet Traversée murale Passaggio nella parete Væggennemføring AWG 315 GL AWG 315 SR AWG 315 L AWG 560 H GL AWG 560 H SR AWG 560 V GL AWG 560 V SR AWG 560 L AWG 600 L ...

Page 2: ...ct WARNING Injury The discharged cold air can cause condensation to be formed in the vicinity of the air outlet f f Ensure that no risk of slipping due to ice forma tion occurs on adjacent footpaths and drive ways during low temperatures CAUTION Injury This product has sharp edges which can cause cuts unless handled with care f f Take care when handling objects with sharp edges and wear protective...

Page 3: ...id Two sections for AWG 315 GL AWG 315 SR AWG 315 L and AWG 600 L three sections for AWG 560 H GL AWG 560 H SR AWG 560 V GL AWG 560 V SR and AWG 560 L Thermal insulation tape Protective cover fitted in the wall outlet Two anti drip caps not for the AWG L 3 2 Accessories Air deflector 4 Mounting Damage to the appliance and environment The weather grille is fitted with a drip edge to prevent condens...

Page 4: ...arry out the following steps once the outer wall of the building is complete after the external rendering or brickwork has been applied to the house D0000036429 4 3 Trimming the insulation Depending on the thickness of the building envelope the in sulation mats prefitted in the wall outlet may need trimming 50 26_03_14_0070 f f Trim the insulation mats until they end 50 mm within the outside edge ...

Page 5: ...rille f f Remove the protective cover that covers the opening to the connectors inside the wall outlet f f Secure the weather grille in the holes in the insert using the screws provided M5 x 10 Ensure that the drip edge of the weather grille is facing downwards Fit anti drip caps not for the AWG L 26_03_14_0140 1 1 Anti drip caps f f On the l h and r h ends of the drip edge affix the anti drip cap...

Page 6: ...ose sleeve to the connection D0000060903 f f Pull the external hose and the thermal insulation below it over the connector f f Tuck the thermal insulation into the outer hose in such a way that the thermal insulation is no longer visible D0000060904 1 1 Hose clamp f f Secure the air hose to the connector using the hose clip f f Tighten the hose clip by turning the screw in the hose clip closure cl...

Page 7: ...let ap erture mm 450x450 830x430 430x830 Max air volume m h 1500 3500 3500 Colour RAL 9006 RAL 9006 RAL 9006 AWG 315 SR AWG 560 H SR AWG 560 V SR 233836 233837 233838 Height mm 490 490 894 Width mm 483 897 483 Depth mm 627 627 627 Weight kg 12 19 19 Wall thickness mm 280 500 280 500 280 500 Pressure drop at 1000 m h Pa 16 Pressure drop at 3000 m h Pa 26 24 Min outlet ap erture mm 450x450 830x430 4...

Page 8: ...gen Salvo error o modificación técnica Rätt till misstag och tekniska ändringar förbehålls Excepto erro ou alteração técnica Zastrzeżone zmiany techniczne i ewentualne błędy Omyly a technické změny jsou vyhrazeny A muszaki változtatások és tévedések jogát fenntartjuk Отсутствие ошибок не гарантируется Возможны технические изменения Chyby a technické zmeny sú vyhradené Stand 9168 tecalor GmbH Lücht...

Reviews: