12 |  

AWG 315-600

INSTALLATION 

Specification

f

f

Seal the transition from the internal hose to the connector 

with the self-adhesive thermal insulation tape supplied.

D

00000

72

40

2

1

1  Hose sleeve

f

f

Pull the sleeves of the sound-optimised hoses 

(LSWP 315-4 S, LSWP 560-4 S) over the connections.

D

00000

72

40

3

f

f

For the sound optimised hoses (LSWP 315-4 S, LSWP 

560-4 S), use the self adhesive thermal insulation pro-

vided to seal the transition from the hose sleeve to the 

connection.

D

00000

60

90

3

f

f

Pull the external hose and the thermal insulation below it 

over the connector.

f

f

Tuck the thermal insulation into the outer hose in such a 

way that the thermal insulation is no longer visible.

D

00000

60

90

4

1

1  Hose clamp

f

f

Secure the air hose to the connector using the hose clip.

f

f

Tighten the hose clip by turning the screw in the hose clip 

closure clockwise with a screwdriver.

5.  Specification

5.1  Dimensions

5.1.1  AWG 315 GL/ AWG 315 SR

95

627

422

422

314

D

00000

17

26

7

5.1.2  AWG 560 H-GL / AWG 560 H-SR

510

340

725

290

422

D

00000

17

26

8

5.1.3  AWG 560 V-GL / AWG 560 V-SR

510

340

290

422

725

D

00000

17

26

9

Summary of Contents for AWG 315 GL

Page 1: ...ATION INSTALLAZIONE Wanddurchführung Wall outlet Traversée murale Passaggio nella parete Væggennemføring AWG 315 GL AWG 315 SR AWG 315 L AWG 560 H GL AWG 560 H SR AWG 560 V GL AWG 560 V SR AWG 560 L AWG 600 L ...

Page 2: ...ct WARNING Injury The discharged cold air can cause condensation to be formed in the vicinity of the air outlet f f Ensure that no risk of slipping due to ice forma tion occurs on adjacent footpaths and drive ways during low temperatures CAUTION Injury This product has sharp edges which can cause cuts unless handled with care f f Take care when handling objects with sharp edges and wear protective...

Page 3: ...id Two sections for AWG 315 GL AWG 315 SR AWG 315 L and AWG 600 L three sections for AWG 560 H GL AWG 560 H SR AWG 560 V GL AWG 560 V SR and AWG 560 L Thermal insulation tape Protective cover fitted in the wall outlet Two anti drip caps not for the AWG L 3 2 Accessories Air deflector 4 Mounting Damage to the appliance and environment The weather grille is fitted with a drip edge to prevent condens...

Page 4: ...arry out the following steps once the outer wall of the building is complete after the external rendering or brickwork has been applied to the house D0000036429 4 3 Trimming the insulation Depending on the thickness of the building envelope the in sulation mats prefitted in the wall outlet may need trimming 50 26_03_14_0070 f f Trim the insulation mats until they end 50 mm within the outside edge ...

Page 5: ...rille f f Remove the protective cover that covers the opening to the connectors inside the wall outlet f f Secure the weather grille in the holes in the insert using the screws provided M5 x 10 Ensure that the drip edge of the weather grille is facing downwards Fit anti drip caps not for the AWG L 26_03_14_0140 1 1 Anti drip caps f f On the l h and r h ends of the drip edge affix the anti drip cap...

Page 6: ...ose sleeve to the connection D0000060903 f f Pull the external hose and the thermal insulation below it over the connector f f Tuck the thermal insulation into the outer hose in such a way that the thermal insulation is no longer visible D0000060904 1 1 Hose clamp f f Secure the air hose to the connector using the hose clip f f Tighten the hose clip by turning the screw in the hose clip closure cl...

Page 7: ...let ap erture mm 450x450 830x430 430x830 Max air volume m h 1500 3500 3500 Colour RAL 9006 RAL 9006 RAL 9006 AWG 315 SR AWG 560 H SR AWG 560 V SR 233836 233837 233838 Height mm 490 490 894 Width mm 483 897 483 Depth mm 627 627 627 Weight kg 12 19 19 Wall thickness mm 280 500 280 500 280 500 Pressure drop at 1000 m h Pa 16 Pressure drop at 3000 m h Pa 26 24 Min outlet ap erture mm 450x450 830x430 4...

Page 8: ...gen Salvo error o modificación técnica Rätt till misstag och tekniska ändringar förbehålls Excepto erro ou alteração técnica Zastrzeżone zmiany techniczne i ewentualne błędy Omyly a technické změny jsou vyhrazeny A muszaki változtatások és tévedések jogát fenntartjuk Отсутствие ошибок не гарантируется Возможны технические изменения Chyby a technické zmeny sú vyhradené Stand 9168 tecalor GmbH Lücht...