INSTALLATION INSTRUCTIONS 

SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017

Table of Contents

1 Safety 

instructions

2 Collector 

basics

3 Assembly 

instructions

 3.1 

Important 

information

4 Installation 

instructions

 

4.1  Planning & installation

5 Mounting

 

5.1  General mounting system information

System Startup

 

6.1  Pressure & Leak Test

 

6.2  Setting the Expansion Tank Pre-charge Pressure

 

6.3  Final Chargin & Venting

 

7  Mainenance & care

8 Warranty

Appendix

A Certifi cations

!

 

CAUTION: READ ALL INSTRUCTIONS BEFORE 
INSTALLING THESE COLLECTORS. 

ADDITIONAL 

ITEMS WILL BE NEEDED TO MOUNT THIS ASSEMBLY.

1 Safety 

Instructions

General Information

Read this entire manual. Failure to follow all the guides, 
instructions and rules could cause personal injury or 
property damage. Improper installation, adjustment, 
alteration, service and use of this unit can result in serious 
injury. This unit must be installed by a professional installer. 
The installation must comply with all national, state and 
local plumbing and electric codes. Proper installation is the 

responsibility of the installer. Failure to comply with the 
installation and operating instructions or improper use voids 
the warranty. Save these instructions for future reference. 
Installers should leave these instructions with the consumer. 
If you have any questions regarding the installation, use or 
operation of this product, or need any additional manuals, 
please call our technical service line at 800.582.8423.

Safety Instructions

!

 

COLLECTOR WARNING: A SOLAR COLLECTOR 
GENERATED HEAT FROM SUNLIGHT. THIS LEADS 

TO THE COLLECTORS AND THEIR CONNECTORS GETTING 
VERY HOT, EVEN WHEN THEY ARE NOT FILLED. COVER 
THE COLLECTORS WITH OPAQUE MATERIAL UNTIL THE 
INSTALLATION HAS BEEN COMPLETED.

!

 

SAFETY VALVE WARNING: NEVER INSTALL ANY 
VALVES OR SHUT-OFF DEVICES IN THE PIPING 

BETWEEN THE COLLECTORS AND THE SAFETY VALVE. THE 
SAFETY VALVE IS ACTIVATED AT 87 PSI.

NEVER SET THE SOLAR LOOP PRESSURE GREATER THAN 
THE DHW WATER SUPPLY PRESSURE. IF THE POTABLE 
WATER PRESSURE IS TOO LOW, A BOOSTER PUMP MAY 
BE NEEDED TO ASSURE THAT IT EXCEEDS THE REQUIRED 
SOLAR LOOP PRESSURE.

The solar system must not bypass auxiliary system safety 
devices.

Check Valve

The Flowstar pump station is equipped with two check 
valves to prevent heat loss from single pipe thermo-
siphoning between the storage tanks and the solar loop and 
collectors.

Drain Valve

Install a drain valve at the lowest point of the system.

Expansion Tanks

The diaphragm-type expansion tanks are designed for 
an operating pressure of 87 psi and are resistant to 
deterioration from propylene glycol mixtures.

Summary of Contents for 230016

Page 1: ...OPERATION AND INSTALLATION HIGH PERFORMANCE FLAT PLATE COLLECTOR SOL 27 PREMIUM S SOL 27 PREMIUM W CLICK ANYWHERE on THIS PAGE to RETURN to SOLAR HOT WATER GUIDES at InspectApedia com...

Page 2: ...instructions or improper use voids the warranty Save these instructions for future reference Installers should leave these instructions with the consumer If you have any questions regarding the insta...

Page 3: ...E ORIGINAL CLASSIFICATION OF THE SYSTEM UNAU THORIZED ALTERATIONS TO THIS SYSTEM COULD RESULT IN A HAZARDOUS CONDITION AND COULD VOID THE MANUFACTURER S WARRANTY Shut down Except for repair and or eme...

Page 4: ...ght 85 5 2171 mm 46 1 1171 mm Width 46 1 1171 mm 85 5 2171 mm Depth 3 8 96 mm 3 8 96 mm Weight 88 2 lb 40 kg 89 3 lb 40 5 kg Casing material Aluminum corrosion resistant Glass cover ESG Glass thicknes...

Page 5: ...llation Pipework Installation Use copper or stainless steel pipes or corrugated stainless steel hoses for the supply and return lines Pipe diameter is depended on length of run and expected ow rates R...

Page 6: ...e nighttime winter temperatures below 30 F may need thicker pipe insulation to prevent pipe freeze ups or slushing of the antifreeze mixture Minimum Insulation Thickness Diameter of Pipe Minimum thick...

Page 7: ...re it is seated in the groove of the collector trim at the top and in the bottom groove of the collector 5 When the grip is positioned correctly tighten the xing screws 6 Attach the remaining grips on...

Page 8: ...TO ONE ANOTHER IF THE SPACER IS REMOVED BEFOREHAND THE CONNECTOR MAY BE DAMAGED WHEN THE SECOND COLLECTOR IS PUSHED INTO PLACE Inter panel connector Spacer Connecting clip 1 Insert the plug in connec...

Page 9: ...en collector and plug in connection 3 Secure the connecting clip by pushing down on the locking tab 4 Install the inlet of the collector array in the same manner Collector Sensor The correct connectio...

Page 10: ...ews in accordance with DIN 571 at least 10 x 80 of stainless steel per collector If multiple arrays of collectors are being installed on a at roof one behind another the recommended spacing between th...

Page 11: ...arrays either SOL 27 Premium S or W panels can be used Use the following pictures and tables for reference when determining how to install your tilt mount collectors Flush Mount Vertical Side by side...

Page 12: ...k 30 60 560203 0 1 1 1 Horizontal X Brace 560206 0 0 1 2 Double Mounting Frame 230170 1 2 3 4 Frame Connector Kit SFC 001 0 1 2 3 Mounting L Bracket Flashing Kits Asphalt 560104 L 4 8 12 16 S5U L 102...

Page 13: ...e and isolation valve Flow Meter S Temperature Sensor T Thermometer Expansion Tank Air Fill Valve Disconnect Valve Solar Collectors S2 S3 T S4 Solar Storage Tank Coil in tank Heat Exchanger mixing val...

Page 14: ...ts that are coated with soapy water and watching the pressure gauge over time Bear in mind that the pressure gauge will vary some based on temperature of the air so one must try to read the pressure a...

Page 15: ...e collector framewall or absorber plate 5 To glass breakage 6 To conditions resulting from the introduction of harmful chemicals caustic uids or liquids deleterious to copper tubing including improper...

Page 16: ...WKH 65 7KLV DZDUG RI FHUWLILFDWLRQ LV VXEMHFW WR DOO WHUPV DQG FRQGLWLRQV RI WKH 3URJUDP JUHHPHQW DQG WKH GRFXPHQWV LQFRUSRUDWHG WKHUHLQ E UHIHUHQFH 7KLV GRFXPHQW PXVW EH UHSURGXFHG LQ LWV HQWLUHW 2 7...

Page 17: ...KH 65 7KLV DZDUG RI FHUWLILFDWLRQ LV VXEMHFW WR DOO WHUPV DQG FRQGLWLRQV RI WKH 3URJUDP JUHHPHQW DQG WKH GRFXPHQWV LQFRUSRUDWHG WKHUHLQ E UHIHUHQFH 7KLV GRFXPHQW PXVW EH UHSURGXFHG LQ LWV HQWLUHW 2 72...

Page 18: ...site Site System operator Installation site Collectors Collectors number type Collector surface area System speci cations System height Pipe run length Ventilation Solar uid type concentration Max ow...

Reviews: