 17 West St., W. Hatfi eld, MA 01088 

|

 800.582.8423 

|

 413.247.3380 

|

 fax 413.247.3369 

|

 [email protected] 

|

 www.stiebel-eltron-usa.com

Simply the Best

INSTALLATION INSTRUCTIONS 

SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017

to the weather must also be checked periodically for their 
condition. Look for signs of abrasion, wear, corrosion, 
contamination, or damage. Check the pH value (> 7) and 
frost protection level (< -20°F) of the heat transfer medium 
annually.

8 Warranty

Stiebel eltron warrants to the original owner that the sol 27 
premium - fl at plate solar collector will be free from defects 
in workmanship and materials for a period of ten (10) years 
from the date of purchase.
Should the part(s) prove to be defective under normal use 
during this period, stiebel eltron, inc. Will be responsible for 
replacement of the defective part(s) only. Stiebel eltron, inc. 
Will not be liable for any costs of transportation, removal, 
reinstallation, or any other labor or freight charges that may 
arise in connection with a warranty claim or any incidental 
or consequential expenses.

This warranty does not apply: 

1.  

To conditions resulting from a failed component or    

 

part that is not part of the solar collector or absorber  

 plate.

2. 

To freeze damage.

3.  

To conditions resulting from misuse, abuse,   

 

 

neglect, accident, or alteration.

4. 

To minor discoloration of the collector framewall  

 

 

or absorber plate.

5. 

To glass breakage.

6.  

To conditions resulting from the introduction of  

 

 

harmful chemicals, caustic fl uids, or liquids deleterious  

 

to copper tubing, including improperly applied or  

 

 

maintained heat transfer fl uids.

 
7. 

To propylene glycol ph levels above 10 or below 8.

 

8.   To periods of stagnation in excess of 60 days.

 
 

9.   To excessive pressure.

 

10.  To clouding or similar occurrence resulting from   

 

 

the normal intrusion of moisture into.

 

11.  To conditions resulting from fl oods, earthquakes,  

  

winds, 

fi re, lightning, or circumstances beyond the  

  

manufacturer‘s 

control.

 

12.  To installation methods which do not conform to   

 

 

relevant national, state or local.

 

Codes and ordinances, good industry practices or 

applicable manuals, diagrams, technical bulletins or  

 

written installation instructions; and, to applications other 
than medium temperature.

To obtain service under this warranty, the owner must fi rst 
secure written authorization from stiebel eltron, inc. The 
owner shall be required to show proof of purchase date, and 
to pay all transportation costs to return the defective part(s) 
for repair or replacement.

 

For any service or warranty related issue, contact 
Stiebel Eltron at:

            

800.582.8423

17 West Street
West Hatfi eld, MA 01088

TOLL FREE 

800.582.8423

PHONE 

413.247.3380

FAX 

413.247.3369

info

@

stiebel-eltron-usa.com

www.stiebel-eltron-usa.com

Printed on recycled chlorine-free paper with soy-based inks.

Due to our continuous process of engineering and technological 
advancement, specifi cations may change without notice.

Summary of Contents for 230016

Page 1: ...OPERATION AND INSTALLATION HIGH PERFORMANCE FLAT PLATE COLLECTOR SOL 27 PREMIUM S SOL 27 PREMIUM W CLICK ANYWHERE on THIS PAGE to RETURN to SOLAR HOT WATER GUIDES at InspectApedia com...

Page 2: ...instructions or improper use voids the warranty Save these instructions for future reference Installers should leave these instructions with the consumer If you have any questions regarding the insta...

Page 3: ...E ORIGINAL CLASSIFICATION OF THE SYSTEM UNAU THORIZED ALTERATIONS TO THIS SYSTEM COULD RESULT IN A HAZARDOUS CONDITION AND COULD VOID THE MANUFACTURER S WARRANTY Shut down Except for repair and or eme...

Page 4: ...ght 85 5 2171 mm 46 1 1171 mm Width 46 1 1171 mm 85 5 2171 mm Depth 3 8 96 mm 3 8 96 mm Weight 88 2 lb 40 kg 89 3 lb 40 5 kg Casing material Aluminum corrosion resistant Glass cover ESG Glass thicknes...

Page 5: ...llation Pipework Installation Use copper or stainless steel pipes or corrugated stainless steel hoses for the supply and return lines Pipe diameter is depended on length of run and expected ow rates R...

Page 6: ...e nighttime winter temperatures below 30 F may need thicker pipe insulation to prevent pipe freeze ups or slushing of the antifreeze mixture Minimum Insulation Thickness Diameter of Pipe Minimum thick...

Page 7: ...re it is seated in the groove of the collector trim at the top and in the bottom groove of the collector 5 When the grip is positioned correctly tighten the xing screws 6 Attach the remaining grips on...

Page 8: ...TO ONE ANOTHER IF THE SPACER IS REMOVED BEFOREHAND THE CONNECTOR MAY BE DAMAGED WHEN THE SECOND COLLECTOR IS PUSHED INTO PLACE Inter panel connector Spacer Connecting clip 1 Insert the plug in connec...

Page 9: ...en collector and plug in connection 3 Secure the connecting clip by pushing down on the locking tab 4 Install the inlet of the collector array in the same manner Collector Sensor The correct connectio...

Page 10: ...ews in accordance with DIN 571 at least 10 x 80 of stainless steel per collector If multiple arrays of collectors are being installed on a at roof one behind another the recommended spacing between th...

Page 11: ...arrays either SOL 27 Premium S or W panels can be used Use the following pictures and tables for reference when determining how to install your tilt mount collectors Flush Mount Vertical Side by side...

Page 12: ...k 30 60 560203 0 1 1 1 Horizontal X Brace 560206 0 0 1 2 Double Mounting Frame 230170 1 2 3 4 Frame Connector Kit SFC 001 0 1 2 3 Mounting L Bracket Flashing Kits Asphalt 560104 L 4 8 12 16 S5U L 102...

Page 13: ...e and isolation valve Flow Meter S Temperature Sensor T Thermometer Expansion Tank Air Fill Valve Disconnect Valve Solar Collectors S2 S3 T S4 Solar Storage Tank Coil in tank Heat Exchanger mixing val...

Page 14: ...ts that are coated with soapy water and watching the pressure gauge over time Bear in mind that the pressure gauge will vary some based on temperature of the air so one must try to read the pressure a...

Page 15: ...e collector framewall or absorber plate 5 To glass breakage 6 To conditions resulting from the introduction of harmful chemicals caustic uids or liquids deleterious to copper tubing including improper...

Page 16: ...WKH 65 7KLV DZDUG RI FHUWLILFDWLRQ LV VXEMHFW WR DOO WHUPV DQG FRQGLWLRQV RI WKH 3URJUDP JUHHPHQW DQG WKH GRFXPHQWV LQFRUSRUDWHG WKHUHLQ E UHIHUHQFH 7KLV GRFXPHQW PXVW EH UHSURGXFHG LQ LWV HQWLUHW 2 7...

Page 17: ...KH 65 7KLV DZDUG RI FHUWLILFDWLRQ LV VXEMHFW WR DOO WHUPV DQG FRQGLWLRQV RI WKH 3URJUDP JUHHPHQW DQG WKH GRFXPHQWV LQFRUSRUDWHG WKHUHLQ E UHIHUHQFH 7KLV GRFXPHQW PXVW EH UHSURGXFHG LQ LWV HQWLUHW 2 72...

Page 18: ...site Site System operator Installation site Collectors Collectors number type Collector surface area System speci cations System height Pipe run length Ventilation Solar uid type concentration Max ow...

Reviews: