11. – PREVENTIVE MAINTENANCE SCHEDULE
MAINTENANCE
TIME
ELEMENT
ACTION
EXTERNAL
Working revision
1000 backwashing
cycles
Complete filter
Filter on + manual backwashing button.
Control:
Engine starting
Valve opening
Efective backwashing cycle (P
1
= P
2
)
Anticorrosion
treatment
12 months
FMA casing
(element 9)
Review anticorrosion treatment in the necessary points.
Apply Epoxi - Polyester treatment
Turret
6 months
Spindle
(element 1.23)
Desmantle the spindle protection (1.32) and lateral rolling
press
Clean and grease spindle both sides.
Use the grease supplied by STF-Filtros.
Rim watertightness
6 months
Rim watertightness
(element 1.10)
Revise the waterlightness of the element 1.10.
Replace the inside joints:
Ø45x4 o-ring seal (element 1.9)
NI joint– 150 20x28x5,5 (element 1.14)
EQ-16 quadric joint (element 1.15)
Scraper 20X28X4,8/7 (element 1.16)
Pressure line
1 week
Intake filter
(element 18)
Intake filter backwashing and microtubes for supplying
water to the backwashing valve.
INTERNAL
Anticorrosion
treatment
12 months
FMA casing
(element 9)
Review anticorrosion treatment in the necessary points
Apply Epoxi - Polyester treatment
Suction nozzle
12 months
Suction nozzle
(element 24.1)
Suction nozzles condition revision, nylon fibers condition,
cartridge proximity.
Smoothing cartridge
12 months
Smoothing cartridge
(element 28)
Smoothing cartridge backwashing
Filtering cartridge
Inactivity period
Filtering cartridge
(element 29)
Backwash manually by using water under pressure, if
necessary, acid or any other chemicals products will be
used
Joints
12 months
Inside joints
Element 11
Element 27.6
Element 27.8
Element 30
Revise inside joints. In case they are deteriorated, they
will be replaced.
Summary of Contents for FMA-2000 series
Page 5: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 5 ...
Page 7: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 7 2 WARRANTY ...
Page 15: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 15 ...
Page 16: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 16 ...
Page 24: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 24 LG FA IC DIF ...
Page 34: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 34 Layout 2 of 2 ...
Page 41: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 41 ...
Page 42: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 42 ...
Page 43: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 43 ...
Page 44: ...Installation operation and maintenance manual FMA 2000 Ref 2000 CPF01 230 VH 44 ...