4 / 28
English
=
WARNING
Missing protective conductor connection leads
to short circuit.
Electric shock hazard!
Connect
protective conductor. Protective conductors may
only be connected by qualified and authorized
personnel.
=
CAUTION
High temperatures.
Risk of burns!
For short-circuit
protection, use fuse size 4 A (gG/gN).
Observe per-
mitted ambient temperatures.
NOTICE
Incorrectly aligned belt alignment lever.
Mate-
rial damage!
Only in case of failure may the belt
alignment roller roll with the belt. The distance
between the belt alignment roller and the belt
edge must be 10-20 mm. The belt edge must
actuate the belt alignment roller in the belt align-
ment roller's lower part.
N.B.
Any mounting position is possible. Reconstruction and alterations to
the device which might affect the safety function are not allowed. The
described products have been developed in order to assume safety
functions as a part of an entire plant or machine. A complete safety
system normally covers sensors, monitoring modules, indicator
switches and concepts for safe disconnection. For the integration of
the device in the entire system: strictly observe and respect the control
category determined in the risk assessment. Therefore, a validation
according to EN ISO 13849-2 or EN 62061 is necessary.
Furthermore,
the Performance Level according to EN ISO 13849-1 and SIL CL Level
according to EN 62061 can be lower than the single level because of
the combination of several safety components and other safety-relat-
ed devices, e.g. by serial connection of switches.
It is the responsibility of the manufacturer of a plant or machine to
guarantee the correct general function. We reserve the right to make
design changes in line with technological progress. steute does not as-
sume any liability for recommendations made or implied by this de-
scription. New claims for guarantee, warranty or liability cannot be de-
rived from this document beyond the general terms and conditions
of delivery.
Maintenance and repair
=
WARNING
Live parts.
Electric shock hazard!
Do not repair
defective or damaged devices. Replace them.
Alternative: Repair of defective device by trained
personnel in agreement with steute and with
steute spare parts.
=
WARNING
Live parts. Unsuitable greases or lubricants can
lead to functional failure and loss of the protec-
tion class.
Electric shock hazard!
Do not use any
greases nor lubricants.
NOTICE
The belt alignment roller may lose its function.
Material damage!
Check belt alignment lever and
belt alignment roller for correct function.
With careful mounting as described above, only minor maintenance is
necessary. We recommend a routine maintenance as follows:
1. Check for correct switch function.
2. Check belt alignment lever and belt alignment roller for
easy operation.
3. Removal of dirt.
4. Check sealing of the cable or conduit connections.
5. Check fix position of the actuator.
Cleaning
=
WARNING
Live parts.
Electric shock hazard!
Clean in ac-
cordance with degree of protection IP66/67.
- Clean by hand with a hand brush or cloth.
- Do not use any knives or sharp-edged tools.
- Do not use any cleaning agents containing solvents.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.