RF CAN Extension Board 4W
Montage- und Anschlussanleitung / Erweiterungsboard
Mounting and wiring instructions / Extension board
Instructions de montage et de câblage / Carte d‘extension
Istruzioni per il montaggio e per il collegamento / Scheda di espansione
Instruções de montagem e instalação / Placa de extensão
Инструкции Монтаж и Коммутация / Плата расширения
Designation
Function
S1, S2
Button to configure the parameters: CAN-ID, CAN-
Baud and CAN-Master (see »Configuration«)
H1, H2, H3,
H4
LEDs (yellow) to indicate the relay states or to dis-
play the configuration values;
e.g. relay K1 tightened -> LED H1 glows (operation
mode)
MD
LED (green) for indicating the device mode.
Operation mode -> LED glows permanently (flashes
during CAN communication);
Configuration mode -> LED uses long and short
flashes to announce the selected parameter (see
»Configuration«)
K1
Closed when CAN bus is connected and the »Safe
Receiver« is not reporting an error; open upon re-
ceipt of CAN error messages or no feedback from
the CAN. CAN error messages that do not cause a
shutdown of the receiver are discarded after 1 se-
cond.
K2
Closed when BT radio connection between foots-
witch and receiver is in Connect or Sniff Mode; open
when wireless connection is not established or no
feedback from CAN.
K3
Closed when the status of the foot switch corre-
sponds to the switching state of the receiver relays;
open when the states are different or no feedback
from CAN.
K4
Closed if the battery voltage is higher than 3.40 V;
open in case of undervoltage (<3.34 V) or no feed-
back from CAN
Configuration
1. Hold button S1 for 3 seconds to enter the configuration mode. LED-
MD flashes.
2. Select parameter type with button S1. - > Blink code LED-MD.
Change the parameter values with button S2. - > 4 bit display LED-
H1…4.
3. Hold button S1 for 3 seconds to return to operation mode.
Code Parameter
Area**
Default Description
1
CAN-ID-High 0000b – 0111b 0010b
CAN ID of »Safe
Receiver« max.
127
2
CAN-ID-Low 0000b – 1111b 0001b
English
Code Parameter
Area**
Default Description
3
CAN-ID-
Baud
0000b – 1000b 1000b
1000b=1M,
0111b=800k,
0110b=500k,
0101b=250k
0100b=125k,
0011b=100k,
0010b=50k,
0001b=20k,
0000b=10k
4
CAN-ID-
Master
0000b – 0001b 001b
0000b=FALSE,
0001b=TRUE
TRUE -> Extension
board starts CAN-
open bus
* LED-MD: Display parameter type (blinks) 1 x Long + »Code« x
Short
** LED-H1..4: Display parameter value H1=bit3, H2=bit2, H3=bit1,
H4=bit0
Maintenance
With rough operating conditions, we recommend routine maintenance
as follows:
1. Check the functions.
2. Remove dirt.
Technical data
1.
CAN_HIGH
2.
CAN_LOW
3.
NC
4.
NC
5.
CAN_GND
6.
NC
7.
CAN_GND
8.
NC
RJ45-CAB socket