ES 41 Z / EM 41 Z / ES 41 WH/90° / ES 51 Z / ES 61 Z / EM 61 Z /
ES 95 Z / ES 95 WH/90° / EM 95 WH/90° / ZS 70 Z / ZS 71 Z
st
eut
e T
echnol
ogies GmbH & Co. K
G
Brück
ens
tr
aße 91, 32584 Löhne, Germany
, www
.s
teut
e.c
om
9 / 20
Montage- und Anschlussanleitung / Seilzugschalter
Mounting and wiring instructions / Pull-wire switch
Instructions de montage et de câblage / Interrupteur à commande par câble
Istruzioni di montaggio e collegamento / Interruttore a fune
Instruções de montagem e instalação / Chave acionada por cabo
Инструкция по монтажу и подключению / Тросовый выключатель
English
Technical data
ES 41 ... / EM 41 ...
Applied standards
EN 60947-5-1
Enclosure
aluminium die-cast, powder-coated
Cover
steel, powder-coated
Degree of protection
IP65 to IEC/EN 60529
Contact material
silver
Switching elements
1 NC/1 NO or 2 NO
Switching system
slow or snap action
Connection
screw connection terminals
Cable cross-section
max. 2.5 mm² (incl. conductor ferrules)
Cable entry
3 x M16 x 1.5
B10d (10 % load)
2 million
TM
max. 20 years
Uimp
4 kV
Ui
400 V
Ithe
6 A
Utilisation category
AC-15
Ie/Ue
6 A/400 VAC
Short-circuit protection
6 A gG/gN fuse
Mechanical
life
> 1 million operations
Operation cycles
max. 3600/h
Ambient temperature
-20°C … +80°C
Actuating force
max. 45 N
Features
pull-wire function
Designation
Ô
ES 51 Z
Applied standards
EN 60947-5-1
Enclosure
aluminium die-cast, powder-coated
Cover
steel, powder-coated
Degree of protection
IP65 to IEC/EN 60529
Contact material
silver
Switching elements
1 NC/1 NO, type Zb
Switching system
slow action
Connection
screw connection terminals
Cable cross-section
max. 2.5 mm² (incl. conductor ferrules)
Cable entry
1 x M16 x 1.5
Uimp
4 kV
Ui
400 V
Ithe
4 A
Utilisation category
AC-15
Ie/Ue
4 A/400 VAC
Short-circuit protection
4 A gG/gN fuse
Mechanical life
> 1 million operations
Operation cycles
max. 3600/h
Ambient temperature
-20°C … +80°C
Actuating force
max. 40 N
Features
pull-wire function
Designation
Ô
ES 61 Z / EM 61 Z
Applied standards
EN 60947-5-1
Enclosure
aluminium die-cast, powder-coated
Cover
steel, powder-coated
Degree of protection
IP65 to IEC/EN 60529
Contact material
silver
Switching elements
1 NC/1 NO or 2 NC, type Zb
Switching system
slow or snap action
Connection
screw connection terminals
Cable cross-section
max. 2.5 mm² (incl. conductor ferrules)
Cable entry
3 x M20 x 1.5
Uimp
6 kV
Ui
400 V
Ithe
ES 61 Z 1Ö/1S: 16 A
ES 61 Z 2S; EM 61 Z 1Ö/1S: 6 A
Utilisation category
AC-15
Ie/Ue
ES 61 1Ö/1S: 16 A/400 VAC
ES 61 2S, EM 61 1Ö/1S: 6 A/400 VAC
Short-circuit protection
ES 61 1Ö/1S: 16 A gG/gN fuse
ES 61 2S, EM 61 1Ö/1S: 6 A gG/gN fuse
Mechanical life
> 1 million operations
Indicator lamp
as option
Operation cycles
max. 3600/h
Ambient temperature
-20°C … +80°C
Actuating force
max. 50 N
Features
pull-wire function
Designation
Ô
ES 95 ...
Applied standards
EN 60947-5-1
Enclosure
fibreglass-reinforced, shockproof
thermoplastic, self-extinguishing UL 94-V0
Degree of protection
IP67 to IEC/EN 60529
Contact materia
l silver
Switching elements
1 NC/1 NO or 2 NO, type Zb
Switching system
slow action, positive break NC contacts
A
Connection
screw connection terminals
Cable cross-section
max. 2.5 mm² (incl. conductor ferrules)
Cable entry
1 x M20 x 1.5
Uimp
4 kV
Ui
400 V
Ithe
6 A
Utilisation category
AC-15; DC-13
Ie/Ue
6 A/400 VAC; 0.25 A/230 VDC
Short-circuit protection
6 A gG/gN fuse
Mechanical life
> 1 million operations
Operation cycles
max. 1800/h
Ambient temperature
-20 °C … +80 °C
Contact opening
2 x 3.5 mm
Actuating force
20 N
Features
pull-wire function
Designation
Ô