7
FlOW TIME aDJUsTMENT
6) By touching the Piezo cap the new flow time will be programmed. In adjusting
mode level 1, each touch increases the flow time by 1 second with a maximum of 10
seconds. You will see the led blinking every time that a new step is performed.
7) If your desired flow time is within 10 seconds, no other adjusting levels are
needed and you can
stop pressing the Piezo
cap. the led will blink
2 times, then 3 times
and after 4 times you
will leave the adjusting
mode. the touch is now
adjusted to the desired
flow time.
8) If you need to perform
steps at adjusting level
2, wait after you see the
led blink twice and then,
perform the needed
quantity of steps (with a
maximum of 10 steps of
2 seconds).
If you do not need more
levels, stop pressing.
the indicator light will
blink 3 times and after 4
times you will leave the adjusting mode. the touch is now adjusted to the desired
flow time.
9) If you need to perform steps at adjusting level 3, wait after you see the led blink
3 times and then, perform the needed quantity of steps (with a maximum of 2 steps
of 15 seconds).
10) to leave the adjusting mode wait until the led blinks 4 times. the touch is
adjusted to the desired flow time.