Stern TOUCH B Installation And Maintenance Manual Download Page 9

7

FlOW TIME aDJUsTMENT

6) By touching the Piezo cap the new flow time will be programmed. In adjusting 

mode level 1, each touch increases the flow time by 1 second with a maximum of 10 

seconds.  You will see the led blinking every time that a new step is performed.  

7) If your desired flow time is within 10 seconds, no other adjusting levels are 

needed and you can 

stop pressing the Piezo 

cap. the led will blink 

2 times, then 3 times 

and after 4 times you 

will leave the adjusting 

mode. the touch is now 

adjusted to the desired 

flow time. 

8) If you need to perform 

steps at adjusting level 

2, wait after you see the 

led blink twice and then, 

perform the needed 

quantity of steps (with a 

maximum of 10 steps of 

2 seconds). 

If you do not need more 

levels, stop pressing. 

the indicator light will 

blink 3 times and after 4 

times you will leave the adjusting mode. the touch is now adjusted to the desired 

flow time. 

9) If you need to perform steps at adjusting level 3, wait after you see the led blink 

3 times and then, perform the needed quantity of steps (with a maximum of 2 steps 

of 15 seconds). 

10) to leave the adjusting mode wait until the led blinks 4 times. the touch is 

adjusted to the desired flow time.

Summary of Contents for TOUCH B

Page 1: ...1 Installation and maintenance guide electro ni cally o perated s e l f cl os ing faucet TOUCH B e BRE...

Page 2: ...ORMATION 4 5 FAUCET INSTALLATION 5 8 FLOW TIME ADJUSTMENT 9 LOW BATTERY INDICATOR 10 BATTERY REPLACEMENT INSTRUCTIONS 10 MAINTENANCE Filter cleaning instructions Care and cleaning of chrome and specia...

Page 3: ...ly Max 70 C Operating water pressure 0 5 8 0 bar 7 116 PSI With water pressure of more than 8 Bars use a pressure reducing valve Power specification 9V low voltage system Power source Touch B 1 x 9V b...

Page 4: ...ht will blink while water runs out of the faucet If you do not need more water just touch the designated area again to stop the water flow before the default time has passed TOUCH B and TOUCH E To ope...

Page 5: ...ck contents Familiarize yourself with the part names and confirm that the parts are included b VERSIONS e VERSIONS 9V Battery box Transformer 1x Tap and attachments BRE VERSION 1x Allen key 2 mm 1x Fi...

Page 6: ...etal particles to enter the faucet Shut off water supply Important All plumbing is to be installed in accordance with applicable codes and regulations FAUCET INSTALLATION Step 1 Remove all mounting ha...

Page 7: ...system 2 Turn on the central water supply and the shut off valves 3 Check for leaks FLOW TIME ADJUSTMENT Adjustment levels The flow time is programmable on site If necessary the default flow time of...

Page 8: ...nt levels Example 1 You wish to adjust the flow time to 20 seconds At level 1 perform 3 steps of 1 second you will get 3 seconds Total 3 seconds Go to level 2 and perform 1 step of 2 seconds you will...

Page 9: ...now adjusted to the desired flow time 8 If you need to perform steps at adjusting level 2 wait after you see the LEDblinktwiceandthen perform the needed quantity of steps with a maximum of 10 steps o...

Page 10: ...light of blinking every time that a new step is performed 6 If your desired flow time is within 10 seconds no other adjusting levels are needed and you can stop pressing the Piezo cap The light will b...

Page 11: ...when the battery level management system has activated step 1 and the user touches the designated area Step 2 At his point the battery might not have enough power to open and close the solenoid valve...

Page 12: ...from the adapter at the solenoid valve housing 3 Remove the filter from the adapter and wash it under running water 4 Reassemble the parts 5 Reconnect the solenoid valve housing and restore the incomi...

Page 13: ...See page 10 Check the flow time See page 5 Check the connection between the piezo cap connector and the solenoid connector Check that the battery box is correctly connected Check the solenoid valve I...

Page 14: ...Screws Kit Cover Kit for Touch B or E Cover Kit for Touch BRE Diaphragm Battery Box for 1 x 9V battery IP 67 Battery Box for 6 x 1 5 AA batteries Transformer Solenoid valve kit for Touch BRE Part Nam...

Page 15: ...price of the faucet valve or control If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information rega...

Page 16: ...14 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 04 13 015225100 C...

Reviews: