Stern TOUCH B Installation And Maintenance Manual Download Page 13

11

sERvIcE chEck lIsT 

No water is coming out of the faucet 

Water flow does not stop

check the  flow time. If needed adjust it 

following the instructions at page. 

check the solenoid valve. If debris or scale is 

present, unscrew the solenoid valve, pull out 

the plunger and the spring and clean them. 

use scale remover if needed. When replacing 

the spring, make sure that it is in vertical 

position.  

Water flow diminished 

check the batteries. low or used up batteries. 

Replace the batteries. see page 10.

check the flow time. see page 5. 

check the connection between the piezo cap 

connector and the solenoid connector. 

check that the battery box is correctly connected.  

check the solenoid valve. If debris or scale are 

present, unscrew the solenoid valve, pull out the 

plunger and the spring and clean them. 

use scale remover if needed. When replacing the 

spring, make sure that it is in vertical position.   

check the diaphragm. If needed, clean the orifice 

or replace it. 

check the water supply pressure.  It must be 0.5-

8.0 bar (7-116 PsI) . With water pressure of more 

than 8 Bars, use a pressure reducing valve.

check the filter. If needed, remove it , clean it and 

reinstall it. see page 10.

Summary of Contents for TOUCH B

Page 1: ...1 Installation and maintenance guide electro ni cally o perated s e l f cl os ing faucet TOUCH B e BRE...

Page 2: ...ORMATION 4 5 FAUCET INSTALLATION 5 8 FLOW TIME ADJUSTMENT 9 LOW BATTERY INDICATOR 10 BATTERY REPLACEMENT INSTRUCTIONS 10 MAINTENANCE Filter cleaning instructions Care and cleaning of chrome and specia...

Page 3: ...ly Max 70 C Operating water pressure 0 5 8 0 bar 7 116 PSI With water pressure of more than 8 Bars use a pressure reducing valve Power specification 9V low voltage system Power source Touch B 1 x 9V b...

Page 4: ...ht will blink while water runs out of the faucet If you do not need more water just touch the designated area again to stop the water flow before the default time has passed TOUCH B and TOUCH E To ope...

Page 5: ...ck contents Familiarize yourself with the part names and confirm that the parts are included b VERSIONS e VERSIONS 9V Battery box Transformer 1x Tap and attachments BRE VERSION 1x Allen key 2 mm 1x Fi...

Page 6: ...etal particles to enter the faucet Shut off water supply Important All plumbing is to be installed in accordance with applicable codes and regulations FAUCET INSTALLATION Step 1 Remove all mounting ha...

Page 7: ...system 2 Turn on the central water supply and the shut off valves 3 Check for leaks FLOW TIME ADJUSTMENT Adjustment levels The flow time is programmable on site If necessary the default flow time of...

Page 8: ...nt levels Example 1 You wish to adjust the flow time to 20 seconds At level 1 perform 3 steps of 1 second you will get 3 seconds Total 3 seconds Go to level 2 and perform 1 step of 2 seconds you will...

Page 9: ...now adjusted to the desired flow time 8 If you need to perform steps at adjusting level 2 wait after you see the LEDblinktwiceandthen perform the needed quantity of steps with a maximum of 10 steps o...

Page 10: ...light of blinking every time that a new step is performed 6 If your desired flow time is within 10 seconds no other adjusting levels are needed and you can stop pressing the Piezo cap The light will b...

Page 11: ...when the battery level management system has activated step 1 and the user touches the designated area Step 2 At his point the battery might not have enough power to open and close the solenoid valve...

Page 12: ...from the adapter at the solenoid valve housing 3 Remove the filter from the adapter and wash it under running water 4 Reassemble the parts 5 Reconnect the solenoid valve housing and restore the incomi...

Page 13: ...See page 10 Check the flow time See page 5 Check the connection between the piezo cap connector and the solenoid connector Check that the battery box is correctly connected Check the solenoid valve I...

Page 14: ...Screws Kit Cover Kit for Touch B or E Cover Kit for Touch BRE Diaphragm Battery Box for 1 x 9V battery IP 67 Battery Box for 6 x 1 5 AA batteries Transformer Solenoid valve kit for Touch BRE Part Nam...

Page 15: ...price of the faucet valve or control If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information rega...

Page 16: ...14 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 04 13 015225100 C...

Reviews: