FaUcET INsTallaTION
Step 3 – Connecting the water supply
1. Fit the pipe to the housing of the solenoid valve. Important: inlet and outlet
should follow the indicating arrow at the solenoid housing.
2. Fit the water supply inlet to the adapter at the solenoid valve housing.
Note:
make sure that the filter is assembled between the housing of the solenoid
valve and the adapter.
Step 4 – Connecting the power source
1.For touch B: Install the battery box at the wall under the sink using the screws or
the two sided adhesive foam tape.
For touch e / BRe: Plug the transformer into the electricity socket.
Important:
In order to avoid entering into the adjusting mode, wait 10 seconds
before operating the system.
2. turn on the central water supply and the shut-off valves.
3. check for leaks.
FloW tIme adJustment
Adjustment levels
the flow time is programmable on site. If necessary, the default flow time of
8 seconds can be adjusted to any value between 1 to 60 seconds. the touch
adjustment mechanism is composed of 3 adjustment levels for changing the flow
time. an indicator light (led) will guide you from one level to the other.
the following table shows the number of steps in each level, the duration of each
step and how to recognize in what adjusting level you are.
Level 1 Level 2 Level 3 Out of adjusting mode
No. of steps
Seconds to be increased by
touching once
Adjustment level indicator
10 steps 10 steps 2 steps
1 second 2 seconds 15 seconds
level 1 is
reached
once
entering into
adjusting
mode
Indicator
light blinks
twice
Indicator
light blinks
3 times
Indicator light blinks 4 times