10
11
INSTALLATION
lIquId SoaP dISPenSeRS
MF lIquId wall Mounted SoaP dISPenSeRS
2030 veRSIonS
INSTALLATION
STEP 1 – INSTALLING THE MF SOAP DISPENSER
1
Cut an adequate opening in the wall for
the dimensions of the soap dispenser
base (where you want to install the
spout) and the corrugated tube.
Disconnect the soap dispenser body with
the rosette from the base by unscrewing
the set screw.
SET SCREW
2
Mount the soap dispenser base into the
opening in the wall and secure it using
the two anchors provided in the package.
Important: The soap dispenser base
should be installed so that the outside
surface of the finished wall falls between
the minimum and maximum lines marked
at the base.
3
Attach the temporary protective soap
dispenser base cover.
4
Assemble the corrugated tube to the
soap dispenser base and make sure it
stays outside the wall when you do the
tiling.
MIN MAx
STEP 2 – cONNEcTING THE POWER SOURcE
1
Remove the protective sticker
covering the sensor.
2
Connect the soap dispenser pump
connector to its matching connector
on the electronic unit. Please
note that since the connector is
waterproof, some pressure must be
applied for a perfect seal.
O-RING VISIBLE –
NOT CONNECTED PROPERLY
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
IMPoRtant:
the 4 contacts connector should be connected properly so that the white
o-ring is not visible and a clicking sound is heard.
PaY attentIon:
If the 4 contacts connectors are not connected properly, the soap
dispenser pump will not operate properly.
3
Plug the transformer into the
electricity socket and connect the
transformer connector
FROM THE TRANSFORMER
TO THE SOAP DISPENSER
4
Wait about 10 seconds before placing
your hands in the sensor range to
avoid adjustment mode.
10
SECONDS
ABOUT