MF SMaRt SoaP dISPenSeR
07292055
MF tRendY SoaP dISPenSeR
07292073
MF GReen SoaP dISPenSeR
07292062
MF eXtReMe SoaP dISPenSeR
07292056
MF elIte SoaP dISPenSeR
07292077
MF Swan SoaP dISPenSeR
07292117
TEcHNIcAL DRAWINGS
lIquId SoaP dISPenSeRS
CHECK CONTENTS
Separate all parts from the packaging and check each part with the ‘pack contents’
section.
Make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not attempt to install the system until you obtain the missing
parts.
IMPORTANT
1) Pay attention to the recommended hole size of the Top Multifeed cap as advised in
the ‘technical data’ section.
2) Keep in mind that when using the faucet installed next to the soap dispenser, the
user hands should not interfere with the soap dispenser sensor detection area.
3) During pre-installation preparations keep in mind the maximum pipe length
provided for the multifeed installation is 3 meters.
WARNINGS
1) Do not install the soap dispensers facing a mirror or any electronic system
operated by an infrared sensor.
2) To prevent reflection problems it is recommended to keep a minimum distance
of
1.50 meters between the soap dispensers and any other objects.
Stern liquid / foam soap dispensers, with proper care, will provide long term trouble
free service. Quality liquid soap of recommended viscosity and pH levels are the main
factors for smooth operation of your dispenser. If needed, use a viscometer to verify the
viscosity of your soap to ensure maximum benefit. The recommended range for soap
viscosity is 100-3800 cPs for liquid and up to 100 cPs for foam soap dispensers. Thicker
liquid soap flows slower and inhibits the pump
valve, causing strain and damage.
Stern liquid / foam soap dispensers are suitable for use with any generic liquid soap of
the correct viscosity and pH. The pH level of all soap used in Stern liquid soap dispensers
should be between 6.5 to 8.5. Lower levels will cause corrosion to the metal dispenser
and even the rubber and plastic components. Higher pH levels will cause swelling to
rubber parts and degradation of plastic components over time.
PRE-INSTALLATION INFO