Sterling Power Pro Batt Ultra BB122470 User Manual Download Page 7

Quick Guide to the

 buttons on the front panel.

Refer to Pages 8 - 11 for in depth procedure  

To operate the Pro Batt Ultra

refer to page 7 (next page)

for instructions.

Force unit to float. On/off toggle.

Turn unit on / off toggle.

Battery type select.

Change Operational on/off voltages

Reset unit to default.

30+

20+

Toggle Power Supply mode
(provides live output voltage)

15+

Display software version 

SVEM* 

Stationary Vehicle Engage Mode 

15+

SVEM*

Stationary Vehicle Engage Mode

Pro Batt Ultra starts charging when input is >13.1V.

Turns off when input is <13.0V. 

30+

OEM* lock

 - disables further 

adjustment of unit’s functions

OEM lock - press Setup button for 30+ seconds - 

4 x red LEDs should light to confirm.

repeat procedure to remove the lock.   

this mode prevents operators tampering with the unit’s 
settings when in the field. The OEM / fitter can set the 
unit up as they desire first, the settings shall be stored, 
then they can apply this lock. 

 Guide to buttons

Press Length (s)

Action

2-5

Forces unit into float mode. Press again to take out of float mode.

5-10

 Turns unit on / off toggle.

10-20

Battery type select - use SETUP / SELECT to toggle between types. Both to confirm.

20-30

Change operational on/off voltages - use both buttons to scroll between voltages.

30+

Reset unit to default - press and hold both buttons for 2 seconds to confirm.

Press Length (s)

Action

0-1

Change to status fault display / back to Voltage display mode.

5-10

 Toggles between 1/2 and 1/1 (full) power. 

10-15

Set Auto Regen. time - use either buttons to toggle between the preferred time.

15-30

Live output voltage (power supply mode) - press SELECT to change to LED 24.

30+

OEM lock

 - disables further adjustment of unit’s functions. 

Press Length (s)

Action

2-5

 Night mode = 1/2 power for 8 hours, then back to full power. 

5-10

Enter standby mode. To take out of standby, repeat. 

10-15

Display software version (displayed in binary on display).

15+

SVEM

 - Stationary Vehicle Engage Mode 

7

Summary of Contents for Pro Batt Ultra BB122470

Page 1: ...nsor USERS MANUAL Sterling Power Products H Charge Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remo...

Page 2: ...e Unit on off Display annotations Page 4 5 Force Unit to half pow er mode Front Label display annotated Sleep timer Off timer adjust Under the lid annotation Custom Battery Profile Selection Pages 11...

Page 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Page 4: ...r bottom red LED is on then the voltage is outside the parameters off the voltmeter 16 High voltage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12...

Page 5: ...ed Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 BB122440 Front Panel II 8 1 2 3 4 6 7 10 11 12 13 9 5 14 5 3 4 1 6 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60...

Page 6: ...on default setting if temperature sensor not fitted Ignition Force mode For true ignition on off mode the Link should be removed As soon as there is a signal 4V on this connector the unit will wake u...

Page 7: ...UP SELECT to toggle between types Both to confirm 20 30 Change operational on off voltages use both buttons to scroll between voltages 30 Reset unit to default press and hold both buttons for 2 second...

Page 8: ...gger voltages only a 10V 20V at 24V low voltage trip With the link wire connected and the ignition feed connected the BB shall operate when the ignition is live However it shall also operate when ther...

Page 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Page 10: ...hen falls below 13 0V x2 for 24V the auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rise...

Page 11: ...s ________ Absorption Maximum 0 960 minutes ________ STERLI G POWER Operation Press and hold both buttons for 10 20 seconds All Left LEDs shall flash Press the setup select button to move LED down to...

Page 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Page 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Page 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Page 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...

Page 16: ...eitshinweise und allgemeinen Bedingungen Auch empfehlen wir Ihnen die Installation durch einen Fachbetrieb durchf hren zu lassen Bestell Nr BB1230 12V 12V 30A BB1260 12V 12V 60A BB122470 12V 24V 70A B...

Page 17: ...Deckel Techn Daten Emfpohlene Kabelst rken und Sicherungen Schnell Installationshilfe Seite 6 Standard Anschluss Skizze Basis Operations Modus Ausf hrliche Installationshilfe Seite 7 8 Installations D...

Page 18: ...n Sicherheits Symbole Beispiel WARNUNG Benutzen Sie das Produkt niemals in Umgebungen wo die M glichkeit einer Gas oder Staub Explosion besteht oder brennbare Produkte sind Generelle Wartung und Repar...

Page 19: ...len Batterietyps dienen die LEDs zur Anzeige des Wertes Status und Fehleranzeigen 16 berspannung Zu hohe Eingangsspannung blinken zu hohe Ausgangsspannung an 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 2...

Page 20: ...m 5m Empf Sicherung 30A Ger t 6mm 10mm 16mm 16mm 25mm 50A 60A Ger t 16mm 25mm 25mm 35mm 35mm 100A Technische Daten bei 24V x2 36V x3 48V x4 Max Eingangsspannung 20V Spannungs Arbeitsbereich 11 19V Aus...

Page 21: ...g entladen wird Automatische Aktivierung und bei Signal eingang mit tiefer Eingangsspannunsregelung Dieses ist eine Kombination der Modi 1 und 3 Automatik und zus tzlich bei Signaleingang bis zu 10V E...

Page 22: ...ES SIGNAL z B Z ndung 7 F r 24V alle Spannungen x 2 f r 36V alle Spannungen x3 und f r 48V alle Spannungen x4 Installationsanleitung 1 3 Direktaktivierung ber externes Signal und sehr tiefe Eingangssp...

Page 23: ...ngs und Ausgangskabel an den Kabelklemmen 5 3 an Achten Sie darauf dass die Kabel entsprechend abgesichert sind Nachdem beide Kabel angeschlossen sind verbinden Sie das Ausgangs Ladekabel mit dem Posi...

Page 24: ...en LEDs 16 24 Es gilt die gr ne Spannungsspalte Einstellung und Abschluss wie 8 10 8 13 Ausgleichsladungszeitfaktor ausw hlen Dieser Faktor bestimmt die berechnete Zeit der Aus gleichsladung Dabei wir...

Page 25: ...Enter Select Das Ger t kann hiermit in den Werk Auslieferzustand zur ckgesetzt werden Alle linken und rechten LEDs blinken abwechselnd Innerhalb von 10 Sekunden muss diese Aktion durch gleichzeitiges...

Page 26: ...ns nicht aktiv Nach 8 Std oder durch Standby oder im Schlafmo dus schaltet das Ger t automatisch wieder zur ck 9 13 Standby ein aus 5 Sekunden Select Durch Dr cken der Select Taste f r mehr als 5 Seku...

Page 27: ...chaltet worden Leuchtet die LED ist das Ger t entweder aktiv in den 1 2 Leistungsmodus geschaltet worden oder die Lei stung wurde aufgrund einer zu hohen Ger tetempe ratur 85 C reduziert In diesem Fal...

Page 28: ...annungen und Zeiten W hlen Sie dann den Batterietyp welcher den Empfehlungen am N chsten ist Aber immer von den Spannungen nach Unten am N chsten Z B empfiehlt der Hersteller 14 5V muss ein Batteriety...

Page 29: ...sGer tnichtimSchlafmodusist Wichtig Ist das Ger t mit der Fernbedienung ausgeschaltet worden geht es zwar in den Schlafmodus wenn die Eingangsspannung abf llt steigt die Spannung wieder an Motor wird...

Page 30: ...bLt Zeit der Hintergrundbeleuchtung 1 600 Sekunden 0 st ndig an Standard 60 br9 Farbwechsel Spannung von rot zu gr n 8 0 13 3V Standard 12 4V b9b Farbwechsel Spannung von gr n zu blau 12 4 16 0V Stand...

Page 31: ...Sicherungen funktionieren und nicht durchgebrannt sind Auch Korrosion kann erheblichen Einfluss auf den Stromfluss haben Ein und Ausschalten des Ger tes mit einer Pause von mindestens 10 Sekunden kom...

Reviews: