Force unit to operate without output battery connected 
( i.e. as a power pack / live output ). 

This mode shall allow the unit to operate without needing a 
voltage on the output terminal. Hold down SETUP/ENTER 
button for 15+ seconds and let go. The boost, absorption 
and float LEDs shall flash. A green LED (18) on the right 
panel should appear and this indicates that voltage check 
is on (default mode) to change it to off (power pack) press 
the SELECT button and a red LED (24) below should turn 
on. With the red LED on the unit shall now operate without 
the need for an output voltage. Press both buttons together 
to save this setting or wait 30 seconds for the unit to reboot. 

On reboot, the 

 comes on for 

HIGH BATT TEMP LED(24)

to confirm power pack mode. 

Force to Float :

Before  accessing  float  mode  please  be  sure  you  know 
what float mode is and what voltage float mode is for your 
profile. Simply hold both buttons down for 2 seconds and 
let go. This will lock the charger into float (BLUE LED - top 
right - number 15 shall come on). The charger shall now 
remain in float and resume bulk/absorption on restarting. 
To force the unit out of float repeat the procedure.  

Force unit off / on: 

  

This  shall  deactivate  the  unit,  output  goes  to  0.0V.  Hold 

both setup and select buttons

 for 5 - 9 seconds. LEDs shall 

turn  off,  the  Bulk  LED  (blue)  shall  flash  once  every  5 
seconds. The unit will remain off, even with normal engine 
cycling  on  and  off  (although  if  the  unit’s  negative  is 
disconnected  from  the  input  battery  then  it  will  resume 
normal operation on re-connection). To turn the unit back 
on, hold the 2 buttons for 5-9 seconds. 

When OFF, the user 

can not access charger’s normal functions.

Force unit to ½ power (stays on until unit is turned off):

    

This will reduce the units power by about 50%. Hold 

setup 

button only

 for 5-9 seconds. To confirm the power reduction 

LED shall flash 5 times. This function will help reduce noise 
in the long term. To return to full power, press the setup 
button again for 5-9 seconds. 

Force unit to ½ power / low speed fan for 8 hours only 
(night mode):    

 

This will reduce the unit’s power by around 50%
for about 8 hours. 

Hold 

select button only

 for 

2-4 seconds

, power reduction shall be confirmed when the 

1/2 power and night LED flashes 4 times. This function will 
help reduce fan noise in the short term, in the evenings, for 
example. The unit will revert back to full power after 8 hours 
automatically. Please note that night mode has to be set 
every single time you wish to use it. It can 

NOT

 be set to 

come on at a certain time daily. 

S

TERLI   G

P

OWER

STANDBY AND SLEEP MODE 
NEED TO BE ENTERED AND 
EXPLAINED PROPERLY.

 Force Options

3

Quick Guide to the

 buttons on the front panel

Force unit to float. On/off toggle.

Turn unit on / off toggle.

Battery type select.

Input cut off voltage.

Reset unit to default.

30+

20+

Toggle Power Supply mode
(provides live output voltage)

15+

Display software version 

battery temp

sensor

Regen timer adjustment: default 240 seconds 
(Regen low voltage timer time).

The default auto Regen time is 240 sec. = 4 min. 
The timer is prepped at 13.2V-19.0V on the input. 
If the input voltage then falls below 13.0V (x2 for 24V) 
the auto regen timer starts to count. If the voltage does
 not rise above 13.2V the timer will not reset and the unit 
will  switch  off,  however,  as  soon  as  the  voltage  rises 
above 13.2V the auto regen timer will automatically reset 
to the set value (default = 240sec).
To deactivate the auto regen mode set the auto regen time 
to 0 seconds.
By pressing the 

Setup / Enter 

only button for more than 10 

seconds you will enter the Auto Regen Time Setup. During 
the  whole Auto  Regen  Setup  the  “Absorption”  LED  will 
flash.
1. Absorption LED flashing and actual saved auto Regen 
time will be displayed on the right bar. Use the 0 to 840 
scale.  If  the  unit  is  out  of  the  factory  the  240  (default) 
should be displayed.
2. Press right button to increase or left button to decrease 
value.
3. To deactivate the auto regen function set timer value to 
0. When happy with your choice either wait 30 seconds or 
press both buttons at the same time for 2 seconds.
4. Absorption LED, AGM II and Auto Mode LEDs will flash 
10 times to confirm value saving. 
5. Unit will restart with new Auto Regen time as default and 
will remain there until changed again.

Important: 

If  you  have  changed  the  cutoff  voltage 

remember  that  the  auto  regen  counter  reset

  functions 

must see 0.2V on top of the new cutoff voltage.
I.e. You set the new cut off voltage at 14.0V. To reset 
the  Auto  Regen  timer  the  voltage  must  rise  above 
14.2V.

SVEM - Stationary Vehicle Engage Mode.

If your usage pattern is mostly stationary, e.g. You are at 
the side of the road and you start the vehicle just to run an 
inverter - the problem is that the vehicle’s alternator may 
only be at 13.1V (and not give a high voltage boost) and 
stay there, in this case the Pro Batt Ultra would not engage 
as it needs greater than  13.2V to start. The ideal solution 
is to have fitted the ignition feed mode (as per explained in 
these instructions). However, if the auto mode was used 
and the ignition feed had not been installed then you could 
use the 

Stationary vehicle engagement mode.

This mode allows the product to engage at a much lower 
voltage (13.1V) and disengage below (13.0V). To select 
this mode: Press SELECT button for 15+ seconds and let 
go, No Fault LEDs should be on solid and the Regen timer 
LED should be solid. To remove this setting then do the 
same again.

Warning:

 

  setting is 

the Stationary Vehicle Engage Mode

operating the unit at voltages which may cause problems 
in the winter to the starting of the vehicle - please bear this 
in mind we do not have enough history with this setting to 
make  any  guarantees  that  it  shall  complement  winter 
conditions - as low voltages could cause vehicle starting 
problems. 

10

0

0

0

1

1

0

1

0

1

12                 13                 14                 15   

1                                26

Display software version

By  pressing  SELECT  for  10-15 
seconds certain LEDs on this column 
shall  briefly  illuminate  to  denote  the 
software  version  in  binary.  From  the 
top  ->  down  ‘

on

’  LEDs  =  1  and  ‘

off

’ 

LEDs = 0. 

For  example,  if  LEDs  8,7,5,3  are  on 
then the binary is 000110101 which, in 
decimals = 

53

. Use a calculator.

Desulph

Calcium

Open

AGM II

GEL II

Sealed 

AGM I

GEL I

Custom

11

10

9

8

7

6

5

4

3

binary #

Summary of Contents for Pro Batt Ultra BB122470

Page 1: ...nsor USERS MANUAL Sterling Power Products H Charge Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remo...

Page 2: ...e Unit on off Display annotations Page 4 5 Force Unit to half pow er mode Front Label display annotated Sleep timer Off timer adjust Under the lid annotation Custom Battery Profile Selection Pages 11...

Page 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Page 4: ...r bottom red LED is on then the voltage is outside the parameters off the voltmeter 16 High voltage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12...

Page 5: ...ed Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 BB122440 Front Panel II 8 1 2 3 4 6 7 10 11 12 13 9 5 14 5 3 4 1 6 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60...

Page 6: ...on default setting if temperature sensor not fitted Ignition Force mode For true ignition on off mode the Link should be removed As soon as there is a signal 4V on this connector the unit will wake u...

Page 7: ...UP SELECT to toggle between types Both to confirm 20 30 Change operational on off voltages use both buttons to scroll between voltages 30 Reset unit to default press and hold both buttons for 2 second...

Page 8: ...gger voltages only a 10V 20V at 24V low voltage trip With the link wire connected and the ignition feed connected the BB shall operate when the ignition is live However it shall also operate when ther...

Page 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Page 10: ...hen falls below 13 0V x2 for 24V the auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rise...

Page 11: ...s ________ Absorption Maximum 0 960 minutes ________ STERLI G POWER Operation Press and hold both buttons for 10 20 seconds All Left LEDs shall flash Press the setup select button to move LED down to...

Page 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Page 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Page 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Page 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...

Page 16: ...eitshinweise und allgemeinen Bedingungen Auch empfehlen wir Ihnen die Installation durch einen Fachbetrieb durchf hren zu lassen Bestell Nr BB1230 12V 12V 30A BB1260 12V 12V 60A BB122470 12V 24V 70A B...

Page 17: ...Deckel Techn Daten Emfpohlene Kabelst rken und Sicherungen Schnell Installationshilfe Seite 6 Standard Anschluss Skizze Basis Operations Modus Ausf hrliche Installationshilfe Seite 7 8 Installations D...

Page 18: ...n Sicherheits Symbole Beispiel WARNUNG Benutzen Sie das Produkt niemals in Umgebungen wo die M glichkeit einer Gas oder Staub Explosion besteht oder brennbare Produkte sind Generelle Wartung und Repar...

Page 19: ...len Batterietyps dienen die LEDs zur Anzeige des Wertes Status und Fehleranzeigen 16 berspannung Zu hohe Eingangsspannung blinken zu hohe Ausgangsspannung an 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 2...

Page 20: ...m 5m Empf Sicherung 30A Ger t 6mm 10mm 16mm 16mm 25mm 50A 60A Ger t 16mm 25mm 25mm 35mm 35mm 100A Technische Daten bei 24V x2 36V x3 48V x4 Max Eingangsspannung 20V Spannungs Arbeitsbereich 11 19V Aus...

Page 21: ...g entladen wird Automatische Aktivierung und bei Signal eingang mit tiefer Eingangsspannunsregelung Dieses ist eine Kombination der Modi 1 und 3 Automatik und zus tzlich bei Signaleingang bis zu 10V E...

Page 22: ...ES SIGNAL z B Z ndung 7 F r 24V alle Spannungen x 2 f r 36V alle Spannungen x3 und f r 48V alle Spannungen x4 Installationsanleitung 1 3 Direktaktivierung ber externes Signal und sehr tiefe Eingangssp...

Page 23: ...ngs und Ausgangskabel an den Kabelklemmen 5 3 an Achten Sie darauf dass die Kabel entsprechend abgesichert sind Nachdem beide Kabel angeschlossen sind verbinden Sie das Ausgangs Ladekabel mit dem Posi...

Page 24: ...en LEDs 16 24 Es gilt die gr ne Spannungsspalte Einstellung und Abschluss wie 8 10 8 13 Ausgleichsladungszeitfaktor ausw hlen Dieser Faktor bestimmt die berechnete Zeit der Aus gleichsladung Dabei wir...

Page 25: ...Enter Select Das Ger t kann hiermit in den Werk Auslieferzustand zur ckgesetzt werden Alle linken und rechten LEDs blinken abwechselnd Innerhalb von 10 Sekunden muss diese Aktion durch gleichzeitiges...

Page 26: ...ns nicht aktiv Nach 8 Std oder durch Standby oder im Schlafmo dus schaltet das Ger t automatisch wieder zur ck 9 13 Standby ein aus 5 Sekunden Select Durch Dr cken der Select Taste f r mehr als 5 Seku...

Page 27: ...chaltet worden Leuchtet die LED ist das Ger t entweder aktiv in den 1 2 Leistungsmodus geschaltet worden oder die Lei stung wurde aufgrund einer zu hohen Ger tetempe ratur 85 C reduziert In diesem Fal...

Page 28: ...annungen und Zeiten W hlen Sie dann den Batterietyp welcher den Empfehlungen am N chsten ist Aber immer von den Spannungen nach Unten am N chsten Z B empfiehlt der Hersteller 14 5V muss ein Batteriety...

Page 29: ...sGer tnichtimSchlafmodusist Wichtig Ist das Ger t mit der Fernbedienung ausgeschaltet worden geht es zwar in den Schlafmodus wenn die Eingangsspannung abf llt steigt die Spannung wieder an Motor wird...

Page 30: ...bLt Zeit der Hintergrundbeleuchtung 1 600 Sekunden 0 st ndig an Standard 60 br9 Farbwechsel Spannung von rot zu gr n 8 0 13 3V Standard 12 4V b9b Farbwechsel Spannung von gr n zu blau 12 4 16 0V Stand...

Page 31: ...Sicherungen funktionieren und nicht durchgebrannt sind Auch Korrosion kann erheblichen Einfluss auf den Stromfluss haben Ein und Ausschalten des Ger tes mit einer Pause von mindestens 10 Sekunden kom...

Reviews: