Using the Instruction Manual

This manual must be read throughout before installing 
this electronic device. Do not lose these instructions - 
keep them safe. The most up to date instructions can 
be found on the Sterling Power website. Please refer to 
the latest instruction manual before contacting Sterling. 
At Sterling, we endeavour to include all of the product 
information that we can think of into the manual.  

Installation of the electronic device must be carried out 
by  a  qualified  and  trained  personnel  only.  The 
personnel  must  be  familiar  with  the  locally  accepted 
guidelines and safety measures. 

Sterling Power’s warranty statement

A comprehensive warranty statement is provide at the 
back  of  the  instruction  manual.  A  comprehensive 
warranty  statement  can  also  be  found  on  sterling-
power.com.

Copyright and plagiarism
 

Copyright © 2015 Sterling Power. All rights reserved.
Reproduction, transfer, distribution or storage of part or 
all of the contents of this document is strictly prohibited. 
If you wish to use all of this document, or excerpts from 
it, Sterling Power must be contacted. 

Liability

Sterling Power can not accept liability for:

Ÿ

consequential damage due to use of this device

Ÿ

possible  errors  in  the  manuals  and  the  results 

thereof

Device modification

Please do not modify the device unless you have been 
instructed to do so by Sterling Power, directly. Product 
modification shall be done at Sterling, when needed. 
Warranty shall be voided if personal attempts are made 
to modify the device, without Sterling’s approval. 

Use the battery to battery charger only:

Ÿ

For DC to DC conversion.

Ÿ

For DC current limiting.

Ÿ

With fuses protecting the DC cables.

Ÿ

In a well ventilated, dry, dust-free and condensation 

free environment. 

Ÿ

When instruction manual has been read through.

 

 

Safety Symbols

Ÿ

Example - WARNING. Never use the device in 

situations  where  there  is  danger  of  gas  /  dust 
EXPLOSION or potentially flammable products. 

General maintenance and repair

The device must be switched off during maintenance. It 
must also be protected against unexpected switching 
off. Remove battery connections and ensure unit is off. 
If repair is required, only use original parts. 

General safety and installation precautions

Ÿ

Install  device  in  well  ventilated  space.  Do  not 

expose  device  to:  Rain,  snow,  spray,  moisture, 
pollution,  condensation.  Do  not  cover  or  obstruct 
ventilation openings.

Ÿ

Device  connects  to  common  negative.  Common 

negative must be earthed. 

Ÿ

In case of fire use a fire extinguisher.

Ÿ

Ensure  reverse  polarity  and  short  circuiting  is 

avoided - to prevent damage to battery.

Ÿ

Protect DC wires with the appropriate sized fuse.

Ÿ

Check cabling annually- fix where needed.

Ÿ

Avoid contact with device with damp hands.

Ÿ

Ensure  the  device  is  adequately  and  securely 

mounted to prevent the unit from displacement.

Ÿ

Use a professional to install device. 

Battery safety

Excessive charge or discharge and high voltages can 
cause serious damage to batteries. Never exceed the 
recommended  limits.  If  battery  acid  contacts  skin  or 
clothing, wash immediately with soap and water. If acid 
enters  the  eye(s),  immediately  flood  the  eye(s)  with 
running  cold  water  for  20  minutes  and  seek  medical 
attention. 

Give extra care to not drop metal tools or jewellery on to 
the battery terminals as short circuiting can take place.
Refrain  from  charging  battery  up  to  4  hours  prior  of 
installation to avoid the formation of explosive gases.

Never smoke / generate a spark around batteries. 

         CAUTION
         WARNING

          
         EXPLOSION

 Legal and Safety

3

Summary of Contents for Pro Batt Ultra BB122470

Page 1: ...nsor USERS MANUAL Sterling Power Products H Charge Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remo...

Page 2: ...e Unit on off Display annotations Page 4 5 Force Unit to half pow er mode Front Label display annotated Sleep timer Off timer adjust Under the lid annotation Custom Battery Profile Selection Pages 11...

Page 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Page 4: ...r bottom red LED is on then the voltage is outside the parameters off the voltmeter 16 High voltage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12...

Page 5: ...ed Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 BB122440 Front Panel II 8 1 2 3 4 6 7 10 11 12 13 9 5 14 5 3 4 1 6 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60...

Page 6: ...on default setting if temperature sensor not fitted Ignition Force mode For true ignition on off mode the Link should be removed As soon as there is a signal 4V on this connector the unit will wake u...

Page 7: ...UP SELECT to toggle between types Both to confirm 20 30 Change operational on off voltages use both buttons to scroll between voltages 30 Reset unit to default press and hold both buttons for 2 second...

Page 8: ...gger voltages only a 10V 20V at 24V low voltage trip With the link wire connected and the ignition feed connected the BB shall operate when the ignition is live However it shall also operate when ther...

Page 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Page 10: ...hen falls below 13 0V x2 for 24V the auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rise...

Page 11: ...s ________ Absorption Maximum 0 960 minutes ________ STERLI G POWER Operation Press and hold both buttons for 10 20 seconds All Left LEDs shall flash Press the setup select button to move LED down to...

Page 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Page 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Page 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Page 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...

Page 16: ...eitshinweise und allgemeinen Bedingungen Auch empfehlen wir Ihnen die Installation durch einen Fachbetrieb durchf hren zu lassen Bestell Nr BB1230 12V 12V 30A BB1260 12V 12V 60A BB122470 12V 24V 70A B...

Page 17: ...Deckel Techn Daten Emfpohlene Kabelst rken und Sicherungen Schnell Installationshilfe Seite 6 Standard Anschluss Skizze Basis Operations Modus Ausf hrliche Installationshilfe Seite 7 8 Installations D...

Page 18: ...n Sicherheits Symbole Beispiel WARNUNG Benutzen Sie das Produkt niemals in Umgebungen wo die M glichkeit einer Gas oder Staub Explosion besteht oder brennbare Produkte sind Generelle Wartung und Repar...

Page 19: ...len Batterietyps dienen die LEDs zur Anzeige des Wertes Status und Fehleranzeigen 16 berspannung Zu hohe Eingangsspannung blinken zu hohe Ausgangsspannung an 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 2...

Page 20: ...m 5m Empf Sicherung 30A Ger t 6mm 10mm 16mm 16mm 25mm 50A 60A Ger t 16mm 25mm 25mm 35mm 35mm 100A Technische Daten bei 24V x2 36V x3 48V x4 Max Eingangsspannung 20V Spannungs Arbeitsbereich 11 19V Aus...

Page 21: ...g entladen wird Automatische Aktivierung und bei Signal eingang mit tiefer Eingangsspannunsregelung Dieses ist eine Kombination der Modi 1 und 3 Automatik und zus tzlich bei Signaleingang bis zu 10V E...

Page 22: ...ES SIGNAL z B Z ndung 7 F r 24V alle Spannungen x 2 f r 36V alle Spannungen x3 und f r 48V alle Spannungen x4 Installationsanleitung 1 3 Direktaktivierung ber externes Signal und sehr tiefe Eingangssp...

Page 23: ...ngs und Ausgangskabel an den Kabelklemmen 5 3 an Achten Sie darauf dass die Kabel entsprechend abgesichert sind Nachdem beide Kabel angeschlossen sind verbinden Sie das Ausgangs Ladekabel mit dem Posi...

Page 24: ...en LEDs 16 24 Es gilt die gr ne Spannungsspalte Einstellung und Abschluss wie 8 10 8 13 Ausgleichsladungszeitfaktor ausw hlen Dieser Faktor bestimmt die berechnete Zeit der Aus gleichsladung Dabei wir...

Page 25: ...Enter Select Das Ger t kann hiermit in den Werk Auslieferzustand zur ckgesetzt werden Alle linken und rechten LEDs blinken abwechselnd Innerhalb von 10 Sekunden muss diese Aktion durch gleichzeitiges...

Page 26: ...ns nicht aktiv Nach 8 Std oder durch Standby oder im Schlafmo dus schaltet das Ger t automatisch wieder zur ck 9 13 Standby ein aus 5 Sekunden Select Durch Dr cken der Select Taste f r mehr als 5 Seku...

Page 27: ...chaltet worden Leuchtet die LED ist das Ger t entweder aktiv in den 1 2 Leistungsmodus geschaltet worden oder die Lei stung wurde aufgrund einer zu hohen Ger tetempe ratur 85 C reduziert In diesem Fal...

Page 28: ...annungen und Zeiten W hlen Sie dann den Batterietyp welcher den Empfehlungen am N chsten ist Aber immer von den Spannungen nach Unten am N chsten Z B empfiehlt der Hersteller 14 5V muss ein Batteriety...

Page 29: ...sGer tnichtimSchlafmodusist Wichtig Ist das Ger t mit der Fernbedienung ausgeschaltet worden geht es zwar in den Schlafmodus wenn die Eingangsspannung abf llt steigt die Spannung wieder an Motor wird...

Page 30: ...bLt Zeit der Hintergrundbeleuchtung 1 600 Sekunden 0 st ndig an Standard 60 br9 Farbwechsel Spannung von rot zu gr n 8 0 13 3V Standard 12 4V b9b Farbwechsel Spannung von gr n zu blau 12 4 16 0V Stand...

Page 31: ...Sicherungen funktionieren und nicht durchgebrannt sind Auch Korrosion kann erheblichen Einfluss auf den Stromfluss haben Ein und Ausschalten des Ger tes mit einer Pause von mindestens 10 Sekunden kom...