Sterling Power Pro Batt Ultra BB122470 User Manual Download Page 12

Sterling Power Products

Copyright 

Opportunity  to  adjust  minimum  absorption  time 
factor

 

Red  High Temp  LED

  will  come  on  constant. 

Yellow 

Absorption  LED

  will  flash  and 

  will  flash 

blue  Float

(section 2 and 4 on graph). This time, adjust the time 
by using the Select and Setup buttons to go up and 
down the right LED column (

refer to the brown scale 0-

960

) to select the correct time. Once content, wait 30 

seconds, or press both buttons to confirm. The unit 
shall then proceed to maximum absorption time factor 
(next below).

S

TERLI   G

P

OWER

During this particular setup procedure we have made 
the voltage setup LED bar more sensitive so that the 
adjustment  can  be  made  in  0.1V  increments.  For 
example, for 13.1V the 13V LED is on and the 13.4V 
LED is flashing. The same idea for 12.9V. The 13V 
LED is on and the 12.6V LED is flashing. 

Remember 

that  you  are  adjusting  the

whilst 

 

Cutoff  voltage 

simultaneous  adjusting  the 

  voltage

Charging

Lower voltage trip and the Low voltage trip

13.4V 

13.4V LED ON

13.3V 

13.4V LED ON + 13.0V LED FLASHING

13.2V 

13.4V LED ON + 13.0V LED ON

13.1V 

13.4V LED FL 13.0V LED ON

13.0V  

13.0V LED ON

12.1V 

12.2V LED FLASHING

12.0V 

12.2V LED FAST FLASHING

To  enter  the  menu  press  (SETUP/ENTER)  & 
SELECT for more than 20 seconds. 

BOOST

CONDITIONING

  and 

ABSORPTION

FLOAT 

LEDs  will  flash  to  indicate 

 

Cutoff  voltage

Setting  Menu.  At  the  same  time  the  actual 

Cutoff 

voltage

 will be displayed in the left LED voltage bar 

according  to  the  description  above.  To  decrease 
voltage  press  SETUP/ENTER  and  to  increase 
voltage press SELECT button.
The 

  range  you  can  choose  is 

Cutoff  voltage

between 12.0V-14.6V. 

Charging voltage is always 0.2V higher.
Lower voltage trip is always 1.1V lower.
Low voltage trip (Mode 3) is always 3.0V lower. 

If you do not touch any buttons for 30 seconds the 
default voltage of 13.0V shall be restored and saved.

To confirm your custom voltage you must press 
both  buttons  (SETUP/ENTER)  and  (SELECT) 
simultanously for 2 seconds.

The chosen voltage will be saved and the unit will 
restart. If you feel unsure do not touch any buttons. 
The default value will be restored automatically. 
  

10

If voltage drops

due to heavy 

load  in excess

 off unit  current

 ability to support

Charging profile Information displayed on top 4 LEDs on main unit 

Fast charge

 constant current

mode 

Stage 1

High absorption 

charge rate constant 

voltage mode 

Stage 2

Lower conditioning 

charge rate constant 

voltage mode 

Stage 3

Float / Power pack

mode, constant

voltage, full current

accessibility

Stage 4 

Backlash voltage. If

 charger power exceeded 

 and battery discharge 

 unit resets to stage 1

Stage 5 

Time 

(Depending on battery size, type, state of charge and charger battery ratio - Digitally processed)

v
o
l
t
s

Flash

3

3

3

Modifying input on / off voltage thresholds. 

The 

default 

input  voltage  thresholds  to  operate  the  Pro 

Batt Ultra are as follows:

Activation  voltage 

13.3V-13.6V  -  the  charger  turns  on 

and charges. If the input voltage drops below 13.3V the 
charger stop charging instantly. If the input voltage then 
goes back to 13.3-13.6V the charger shall charge again.
  
13.6V+ - the charger turns on and charges. In addition, the 
low voltage timer for regenerative braking activates. So, 
now, if the input voltage drops to between 12.0V - 

Timer 

activation V

13.3V the default 120 second timer shall begin 

and the charging shall continue for 120 seconds. To then 
reset this timer the input voltage has to go above 13.6V+ 
again.  If  the  input  voltage  only  goes  to  13.3V-13.6V  the 
charger shall start charging but shall not reset the timer. If 
12.0V - 13.3V is maintained for longer than 120 seconds 
the charger turns off. 

12.0V  -  13.3V  -  this  is  the  regen.  braking  operational 
window - only activated when the default 120 second timer 
has been activated (input voltage at 13.6V+). Provided the 
input voltage remains between 12.0V - 13.3V for over 120 
seconds the unit shall stop charging. 

Low voltage trip V

<12V - below 12.0V shall result in the 

charger turning off immediately - unless in operation mode 
3.

11.5V  -  Low  voltage  cut  off,  applicable  only  when  in 
operational mode 3. The   

Charging voltage   

                

13.2V

  

 

                  13.0V

Cutoff voltage      

Lower voltage trip 

                

12.0V

Volt. trip w/ ign (Mode 3)

      

10.0V

CUSTOM INPUT CUTOFF VOLTAGE 
SETTING:    
                  (voltages x 2 for 24V)

Here  you  can  adjust  the  input  voltage 
setting that prompts the unit into sleep 
mode.
This  unit  has  3  different  cut  off  preset 
voltages.  In  Auto  Mode  the  cut  off 
default is 13.3V and in Regen Braking 
Mode the cut off default is 12.0V. The 
higher  figure  (Auto  Mode)  and  lower 
figure (Regen Braking) are both pegged 
together by a 1.3V gap. As these figures 
are  pegged,  when  you  change  Auto 
Mode you change Regen voltage to be 
1.3V lower.
We have designed it, therefore, so you 
can only tune the higher voltage (Auto), 
this,  then  changes  the  lower  voltage, 
respectively (by 1.3V). The 3rd cut off 
voltage is only relevant when in mode 3, 
the  low  voltage  trip  is  pegged  at  1.8V 
lower than the Auto Mode voltage. 
For  example,  if  you  want  the  Regen 
cutoff  voltage  to  be  11.7V  -  set  the 
higher  voltage  to  13.0V  (11.7V+1.3V). 
The low voltage trip (if in mode 3) is then 
11.2V.
 

Adjustment of operational voltages.

The 4 main control voltages below are inextricably linked. 
The  voltages  can  only  be  adjusted  as  a  block  (not 
individually). For example, if you wish to reduce the 

Cutoff 

voltage

 by 0.2V then all other voltages in the block shall 

reduce by 0.2V. 

Opportunity  to  adjust  maximum  absorption 
time factor 

Red High Temp LED

 will come on constant. 

Green 

Conditioning LED

 will flash and 

 will flash 

blue Float

(section 3 and 4 on graph). This time, adjust the time 
by using the Select and Setup buttons to go up and 
down the right LED column (

refer to the brown scale 

0-960

) to select the correct time. Once content, wait 

30 seconds, or press both buttons to confirm.

 from the middle of each row will flash 

green LED

for  around  8  seconds  to  confirm  the  setup  is 
completed. The unit will then restart. 

regen braking timer

All  4  voltages  are  always 
linked.  This  block  can  be 
adjusted  by  changing  the 

Cutoff voltage

 value up and 

down.  This  subsequently 
changes  the  other  three 
voltages by the same value. 

Charging voltage (default 13.2V) (always 0.2V above 

Cutoff  voltage)

:

  At  this  voltage  the  charger  starts 

charging. After 5 seconds above 13.2V the regen braking 
timer is set. If the input voltage drops to 11.9V - 13.0V this 
timer begins. Timer reset when input voltage is 13.2V+.

Cutoff  voltage  (default  13.0V):

  This  voltage  is  only 

relevant after the 

charging voltage

 has been met and the 

charger is charging. When the input voltage drops below 
this  cutoff  voltage  the  charger  stops  charging  and  shall 
eventually  go  to  sleep.  If  the  input  voltage  remains 
between 13.0V-13.2V the charger shall continue charging.  
The 

Cutoff  voltage  is  the  parameter  that  the  user 

changes. 

Cutoff voltage

As noted, by adjusting the 

 you 

change the other three voltages mentioned by the same 
amount.  

Lower voltage trip (default 11.9V) (always 1.1V below 

Cutoff voltage)

When the input voltage drops below the 

Lower  voltage  trip

  the  charger  turns  off.  The  11.9V 

threshold  is  only  relevant  if  the 

  is 

regen  braking  timer

activated.  If  not,  then  the  low  voltage  trip  is  13.0V.  If  in 
mode 3, the low voltage trip is 10.0V.

Low voltage trip (default 10.0V) (Mode 3) (always 3.0V 
below 

:

 Only when in operation mode 3 

Cutoff voltage)

does the Pro Batt Ultra work down as low at this voltage.     

Input voltage

12

Summary of Contents for Pro Batt Ultra BB122470

Page 1: ...nsor USERS MANUAL Sterling Power Products H Charge Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remo...

Page 2: ...e Unit on off Display annotations Page 4 5 Force Unit to half pow er mode Front Label display annotated Sleep timer Off timer adjust Under the lid annotation Custom Battery Profile Selection Pages 11...

Page 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Page 4: ...r bottom red LED is on then the voltage is outside the parameters off the voltmeter 16 High voltage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12...

Page 5: ...ed Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 BB122440 Front Panel II 8 1 2 3 4 6 7 10 11 12 13 9 5 14 5 3 4 1 6 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60...

Page 6: ...on default setting if temperature sensor not fitted Ignition Force mode For true ignition on off mode the Link should be removed As soon as there is a signal 4V on this connector the unit will wake u...

Page 7: ...UP SELECT to toggle between types Both to confirm 20 30 Change operational on off voltages use both buttons to scroll between voltages 30 Reset unit to default press and hold both buttons for 2 second...

Page 8: ...gger voltages only a 10V 20V at 24V low voltage trip With the link wire connected and the ignition feed connected the BB shall operate when the ignition is live However it shall also operate when ther...

Page 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Page 10: ...hen falls below 13 0V x2 for 24V the auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rise...

Page 11: ...s ________ Absorption Maximum 0 960 minutes ________ STERLI G POWER Operation Press and hold both buttons for 10 20 seconds All Left LEDs shall flash Press the setup select button to move LED down to...

Page 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Page 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Page 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Page 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...

Page 16: ...eitshinweise und allgemeinen Bedingungen Auch empfehlen wir Ihnen die Installation durch einen Fachbetrieb durchf hren zu lassen Bestell Nr BB1230 12V 12V 30A BB1260 12V 12V 60A BB122470 12V 24V 70A B...

Page 17: ...Deckel Techn Daten Emfpohlene Kabelst rken und Sicherungen Schnell Installationshilfe Seite 6 Standard Anschluss Skizze Basis Operations Modus Ausf hrliche Installationshilfe Seite 7 8 Installations D...

Page 18: ...n Sicherheits Symbole Beispiel WARNUNG Benutzen Sie das Produkt niemals in Umgebungen wo die M glichkeit einer Gas oder Staub Explosion besteht oder brennbare Produkte sind Generelle Wartung und Repar...

Page 19: ...len Batterietyps dienen die LEDs zur Anzeige des Wertes Status und Fehleranzeigen 16 berspannung Zu hohe Eingangsspannung blinken zu hohe Ausgangsspannung an 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 2...

Page 20: ...m 5m Empf Sicherung 30A Ger t 6mm 10mm 16mm 16mm 25mm 50A 60A Ger t 16mm 25mm 25mm 35mm 35mm 100A Technische Daten bei 24V x2 36V x3 48V x4 Max Eingangsspannung 20V Spannungs Arbeitsbereich 11 19V Aus...

Page 21: ...g entladen wird Automatische Aktivierung und bei Signal eingang mit tiefer Eingangsspannunsregelung Dieses ist eine Kombination der Modi 1 und 3 Automatik und zus tzlich bei Signaleingang bis zu 10V E...

Page 22: ...ES SIGNAL z B Z ndung 7 F r 24V alle Spannungen x 2 f r 36V alle Spannungen x3 und f r 48V alle Spannungen x4 Installationsanleitung 1 3 Direktaktivierung ber externes Signal und sehr tiefe Eingangssp...

Page 23: ...ngs und Ausgangskabel an den Kabelklemmen 5 3 an Achten Sie darauf dass die Kabel entsprechend abgesichert sind Nachdem beide Kabel angeschlossen sind verbinden Sie das Ausgangs Ladekabel mit dem Posi...

Page 24: ...en LEDs 16 24 Es gilt die gr ne Spannungsspalte Einstellung und Abschluss wie 8 10 8 13 Ausgleichsladungszeitfaktor ausw hlen Dieser Faktor bestimmt die berechnete Zeit der Aus gleichsladung Dabei wir...

Page 25: ...Enter Select Das Ger t kann hiermit in den Werk Auslieferzustand zur ckgesetzt werden Alle linken und rechten LEDs blinken abwechselnd Innerhalb von 10 Sekunden muss diese Aktion durch gleichzeitiges...

Page 26: ...ns nicht aktiv Nach 8 Std oder durch Standby oder im Schlafmo dus schaltet das Ger t automatisch wieder zur ck 9 13 Standby ein aus 5 Sekunden Select Durch Dr cken der Select Taste f r mehr als 5 Seku...

Page 27: ...chaltet worden Leuchtet die LED ist das Ger t entweder aktiv in den 1 2 Leistungsmodus geschaltet worden oder die Lei stung wurde aufgrund einer zu hohen Ger tetempe ratur 85 C reduziert In diesem Fal...

Page 28: ...annungen und Zeiten W hlen Sie dann den Batterietyp welcher den Empfehlungen am N chsten ist Aber immer von den Spannungen nach Unten am N chsten Z B empfiehlt der Hersteller 14 5V muss ein Batteriety...

Page 29: ...sGer tnichtimSchlafmodusist Wichtig Ist das Ger t mit der Fernbedienung ausgeschaltet worden geht es zwar in den Schlafmodus wenn die Eingangsspannung abf llt steigt die Spannung wieder an Motor wird...

Page 30: ...bLt Zeit der Hintergrundbeleuchtung 1 600 Sekunden 0 st ndig an Standard 60 br9 Farbwechsel Spannung von rot zu gr n 8 0 13 3V Standard 12 4V b9b Farbwechsel Spannung von gr n zu blau 12 4 16 0V Stand...

Page 31: ...Sicherungen funktionieren und nicht durchgebrannt sind Auch Korrosion kann erheblichen Einfluss auf den Stromfluss haben Ein und Ausschalten des Ger tes mit einer Pause von mindestens 10 Sekunden kom...

Reviews: