10
3.1 Control box
Dimensions:
Width 250 x Height 340 x Depth 150 mm
3.1.1 Location-attachments
STERILOR Sel
3.1.2 Location
The electronic box must be installed in the technical room protected from sunlight, bad weather and close
to the electrolysis cell (2.5 m cable).
The controls of the box (switch, electrode connection and fuse holder) must remain accessible.
Fix the box securely against a wall via the 4 fixing holes using the screws and plugs supplied.
Necessary equipment
:
-
Drilling machine and 6 mm drill bit suitable for the support, plugs supplied = plastic expansion plugs (to be
adapted to the support if necessary).
-
Phillips screwdriver.
3.1.3 Electric connections
The system operates in parallel with the filtration pump.
It must operate at the same time as the filtration system. A box continuously connected to a separate
socket will annul the guarantee.
Before carrying out any electrical work on the box, this connection requires STERILOR Sel's power
supply to be cut off at the filtration box.
The connection is therefore made on the filtration pump contactors in the existing filtration box,
according to the following diagram:
¾ salt electrolysis
cell installed