2. Select a suitable location for the disinfection system
and its related components. As it is recommended
to install a ground fault protected circuit (GFCI), make sure that this is taken
into consideration prior to any installation. When selecting a mounting
location, you must leave enough space to allow for the removal of the UV
lamp/quartz sleeve, as well as enough space to change out the filter cartridges
(typically leave a space equal to the size of the reactor chamber itself above
and below) (Figure 1A).
(Note: Installation drawings show Cobalt “pLUs” system with UV sensor for
representation purpose only)
3. Mount the system to the wall with appropriate
lag bolts (not supplied) through the two
mounting holes located on the metal bracket.
The use of a flow restrictor device is strongly
recommended when installing your system in
order to maintain the manufacturers maximum
rated flow. The flow restrictor should be installed
on the outlet port and is designed to be installed
in one direction only. Ensure that the flow of the
water matches the flow direction as indicated on
the flow restrictor (Figure 1B). DO NOT SOLDER
CONNECTIONS WHILE ATTACHED TO THE
SYSTEM AS THIS COULD DAMAGE THE O-RING
SEALS.
4. Make sure you allow for a “drip-loop” on the
power cord and sensor (SCM series) to prevent
any water from potentially entering the
controller. Run lamp and sensor cord under
ballast, to prevent water from potentially entering the controller (Figure 1C).
Affix the green ground wire to the grounding lug at the top of the reactor
vessel and securely fasten with the lugnut provided (Figure 1D).
5. Install the UV lamp and UV sensor as outlined on pages 7-9.
6. Install the cartridges as outlined on page 10.
7. When all plumbing connections are made, slowly turn on the water supply
and check for leaks. The most likely cause for leaks is from o-ring seals. In
case of a leak at the reactor, shut water off, drain cell, remove the retaining
nut, wipe the o-ring and threads clean and re-install. In case of a leak at the
filters, remove the sump, wipe the o-ring and threads clean, ensure the o-ring
is fitted properly, then reinstall.
optional 4-20Ma “Y” cable