12
Specifications:
MODEL
SC200-A
SC410-A
Flow R
ate
1
US Public Health
16mJ/cm
2
56.8 lpm
(15 gpm)
(3.4 m
3
/hr)
111.2 lpm
(29.4 gpm)
(6.7 m
3
/hr)
VIQUA Standard
30 mJ/cm
2
30.3 lpm
(8 gpm)
(1.8 m
3
/hr)
59.3 lpm
(15.7 gpm)
(3.6 m
3
/hr)
NSF/EPA
40mJ/cm
2
22.7 lpm
(6 gpm)
(1.4 m
3
/hr)
44.5 lpm
(11.7 gpm)
(2.7 m
3
/hr)
Overall Dimensions
(width x Depth x Height)
34.3 x 8.9 cm
(13.5” x 3.5”)
55.4 x 8.9 cm
(21.8” x 3.5”)
Inlet/Outlet Port Size
1“ FNPT/
Combo 3/4“ FNPT &
1“ MNPT
1“ FNPT/
Combo 3/4“ FNPT &
1“ MNPT
Shipping Weight
5.1kg (11.3lbs)
6.8kg (15.0lbs)
Electrical
Voltage
100-240V/50-60Hz
100-240V/50-60Hz
Power
Consumption
35 W
60 W
Lamp Watts
27 W
46 W
Maximum Operating Pressure
8.62bar (125psi)
8.62bar (125psi)
Ambient Water
Temperature
2-40˚C (36-104˚F)
2-40°C (36-104°F)
Lamp Type
Sterilume™-HO
(high-output)
Sterilume™-HO
(high-output)
Visual “Power-On”
Yes
Yes
Audible Lamp Failure
Yes
Yes
Lamp Replacement Reminder
Yes
Yes
Visual Lamp Life
Remaining
Yes
Yes
Total Running Time
Yes
Yes
254nm UV Monitor
No
No
Solenoid Output
(solenoid not incl.)
No
No
Chamber Material
304 SS
304 SS
1.