READING THE DISPLAY 

 

Normal Run: Indicates that 
Emitters are lit and There are 
no alarm conditions 

Emitters Off: A flashing run light 
Indicates  that  the  emitters  are 
turned off. 
 
 

Bank  Faults:  These  alarms  indicate  that  an 
emitter  or  power  supply  may  need  attention. 
Cycling the emitters power off/on or a reset will 
clear the alarm.  
 
 

 
Bank Over Current: Fast flashing bank lights indicates that one or more banks are drawing 
more current than the watchdog was designed for. 
 
 
 
 

Replace Emitters: Both bank lights flashing every second indicates that the emitters have reached 
the  end  of  their  useful  lifespan.  The  9,000-hour  timer  runs  only  when  power  is  applied  to  the 
emitters. Replace with authentic Steril-Aire emitters for maximum output and lifespan. Blinks once 
every second. 
 
 

MENU DISPLAYS AND FUNCTIONS 

 

Display a menu by clicking the reset button.  Select the desired menu by clicking through the menus. If you missed your 
menu, keep clicking until your menu is displayed again. If you wait long enough, the menu will time out and normal operation 
will resume. Once the desired menu is displayed, press and hold the reset button until the menu display changes. 
 

Menu 0: Reset Emitter Fault: Use the reset emitter fault by holding the reset button down or cycle 
through the menu. A successful reset will be followed by a marque pattern of LED’s. This pattern 
will repeat itself 8 times. 
 
 
 
 
Menu 1: Report Run Hours: This is part of the 9,000-hour timer. Hold the reset button until the 
green run LED starts to flash. Each flash of the LED indicated that 1,000-hours has expired. At 
9,000-hours,  the  end  of  emitter  life  alarm  will  flash.  This  function  will  keep  counting  even  after 
9,000-hours has expired. 
 
 
Menu 2: This menu is reserved and has no function at this time. 
 
 
 
 
 
 
Menu 3: Reset 9,000 Hour Timer: This menu resets the runtime timer. It will clear the 9,000-hour 
timer after emitters have been replaced by  installing authentic Steril-Aire emitters for maximum 
output and lifespan. Hold the reset button until the display normal run status. 
 
 

Emitters Off. 
No Alarm. 

 Bank 1 Off 

 Run Flashing 

 Bank 2 Off 

Bank 1 Fault. 
BMS Alarm 

 Bank 1 On 

 Run Off 

 Bank 2 Off 

Bank 2 Fault. 
BMS Alarm 

 Bank 1 Off 

 Run Off 

 Bank 2 On 

Bank 1 & 2 Fault. 
BMS Alarm 

 Bank 1 On 

 Run Off 

 Bank 2 On 

Bank 1 & 2 Over Current. 
BMS Alarm

 

 Bank 1 Flashing 

 Run On 

 Bank 2 Flashing 

Replace Emitters. 
No Alarm 

 Bank 1 Blink  

 Run Blink 

 Bank 2 Blink 

Menu 0 
Reset 

 Bank 1 Off 

 Run Off 

 Bank 2 Off 

 

Menu 1 
Report Run Hours 

 Bank 1 On 

 Run Off 

 Bank 2 Off 

 

Menu 2 
Not Assigned 

 Bank 1 On 

 Run On 

 Bank 2 Off 

 

Menu 3 
Reset 9K timer 

 Bank 1 On 

 Run On 

 Bank 2 On 

 

Normal Run. 
No Alarm. 

 Bank 1 Off 

 Run On 

 Bank 2 Off 

Summary of Contents for 8100PVAB

Page 1: ... personal injury or product and property damage WARNING Before performing maintenance ensure unit is unplugged Electrical shock can cause death CAUTIONS Never expose eyes or skin to UVC light Wear gloves face shield glasses per ANSI Z87 1 and cover all exposed skin Do not touch EmitterTM glass without gloves Damage to Emitter may result Oil from fingerprints will permanently etch glass of Emitter ...

Page 2: ...nner door This compartment should be opened by a qualified electrician only 7 Connect BMS BMS includes Door and or watchdog 8 Connect Bank 1 and Bank 2 Ensure that both banks carry relatively equal load for proper watchdog operation Ensure proper circuit breaker and grounding wire torque 9 Connect Mains Ensure proper circuit breaker and grounding wire torque 10 Torque the circuit breakers CB1 CB2 ...

Page 3: ...ns Line output fuse PN 80004125 500 Line output fuse low voltage circuit PN 80004115 1000 Door Switch Connection TB2 Ground Bar Circuit Breakers Watchdog Reset Display Watchdog connection to BMS dry contacts Door Switch Connection ...

Page 4: ...t by holding the reset button down or cycle through the menu A successful reset will be followed by a marque pattern of LED s This pattern will repeat itself 8 times Menu 1 Report Run Hours This is part of the 9 000 hour timer Hold the reset button until the green run LED starts to flash Each flash of the LED indicated that 1 000 hours has expired At 9 000 hours the end of emitter life alarm will ...

Page 5: ...________________________________________________________________________________________________________ Thank you for choosing Steril Aire 1 UVC for HVAC solution provider worldwide Please contact your local supplier or Steril Aire directly if we can provide any further information or service Call 1 818 565 1128 or visit www steril aire com Your satisfaction is very important to us The health asp...

Page 6: ......

Reviews: