y:\pasteuriser\pasteuriser
manuals
\manuals 2019\s90refcool
manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc
Date Printed: 03/12/2019
Page No.
47
PARAMETER LIST
Description
Default
Value
Minimum
Value
Maximum
Value
Units
C1 Past. Temp
62.5
50.0
68.0
°C
The temperature at which the bath is maintainted during pasteurisation on cycle 1
C1 Past Time (1)
30
3.5
35
minutes
The time of pasteurisation in cycle 1
C1 Chill Temp
4.0
3.5
10.5
°C
The chill temp of the chilling cycle in cycle 1
C1 Differential time
1.40
0.30
30
minutes
The time at which the drain starts before the end of pasteurising cycle in cycle 1
C2 Past. Temp
62.5
50.0
68.0
°C
The temperature at which the bath is maintainted during pasteurisation on cycle 2
C2 Past Time (1)
30
3.5
35
minutes
The time of pasteurisation in cycle 2
C2 Chill Temp
4.0
3.5
10.5
°C
The chill temp of the chilling cycle in cycle 2
C2 Differential time
1.40
0.30
4
minutes
The time at which the drain starts before the end of pasteurising cycle in cycle 2
LMC1 Rapid Heating Stop Point
61.5
58
62
°C
The temperature to which the bath is rapid heated during the heating cycle 1
LMC2 Rapid Heating Stop Point
61.5
58
67
°C
The temperature to which the bath is rapid heated during the heating cycle 2
Warmer Set
37.0
30.0
68.0
°C
The bath temperature setpoint for the warmer cycle
Over Water Level
245
230
240
mm
High Water Level
225
200
225
mm
Neck Water Level
– Double Storey
220
160
225
mm
Neck Water Level
– Single Storey
165
160
225
mm
Low Water Level
130
90
135
mm
The dimensions for water level set-up
Language