WATER LEVEL SET UP
– PAGE 2
1. From the level screen enter the level values by pressing on the value window for
each of the following: (Measured in mm).
o
Over Level [Default 245 +5/-5]
o
High Level [Default 225 +5/-5]
o
Double Storey Neck Level [Default 220 +0/-5]
o
Single Storey Neck Level [Default 165 +0/-5]
o
Low Level [Default 130 +5/-5]
2. Type in the value and press enter
3. Using the fill to next level button, check levels via tape measure or rule
Note: the measured point should be at the lowest point i.e. From the drain position
.
o
If the levels are out of tolerance especially the neck level, add an offset in the
‘apply offset’ window. i.e. +value to add more level and –value to reduce the level.
If you are finished with the water level press the configuration button
to return to the configuration menu.
Then press on
button to return to the main screen
If the drain time needs to be changed please go to the next page of this manual while in
the level set up screen.