19
USA and Canada 800.683.2378, International 904.641.1666
Econ T
INSTALLATION
continued
INSTALL DISCHARGE LINE TO PUMP HEAD AND INJECTION POINT
1.
Make a secure finger tight connection on the discharge fitting of the pump head as
instructed in Install Suction Line instructions.
DO NOT use thread sealant tape on pump tube connections or tools to
tighten connections.
HAZARDOUS PRESSURE: Shut off water or circulation system
and bleed off any system pressure.
Locate a point of injection beyond all pumps and filters or as determined by
the application.
2.
A 1/4" or 1/2" Female NPT (FNPT) connection is required for installing the injection
fitting. If there is no FNPT fitting available, provide one by either tapping the pipe or
installing FNPT pipe tee fitting.
3.
Wrap the Male NPT (MNPT) end of injection fitting with 2 or 3 turns of threading tape.
If necessary, trim the injection fitting quill as required to inject product directly into
flow of water.
Trim injection fitting end
DO NOT use Teflon
tape on pump
tube threads.
DO NOT use pliers.
Injection Check Valve
or Injection Fitting
Shut-Off Valve
1/4" or 1/2" FNPT
Reduction Bushing
Typical Point of Injection
Summary of Contents for E10T1A
Page 1: ...ECON SERIES T PUMP INSTALLATION AND MAINTENANCE MANUAL PERISTALTIC METERING PUMPS SINCE 1957 ...
Page 30: ...30 www stenner com Econ T FOR YOUR RECORDS Model Serial Number Date of Installation ...
Page 31: ...31 USA and Canada 800 683 2378 International 904 641 1666 Econ T MOUNTING TEMPLATE ...
Page 62: ...30 www stenner com Econ T PARA SU REGISTRO Modelo Número de Serial Fecha de instalación ...
Page 63: ...31 EE UU y Canadá 1 800 683 2378 Internacional 1 904 641 1666 Econ T PLANTILLA DE MONTAJE ...