18
www.stenner.com
Econ T
INSTALLATION
continued
3
"
INSTALL SUCTION WEIGHT TO SUCTION LINE
1.
Drill a hole into the bung cap or solution tank lid. Slide the tubing through and
secure the weighted strainer to the line.
2.
To attach the strainer, push approximately 3.5" of suction line through the cap
on the strainer body. Pull tubing to make sure it is secure.
3.
Suspend slightly above tank bottom to reduce the chance of sediment pickup.
DO NOT mix additives in the solution container. Follow recommended mixing
procedures according to the manufacturer.
DO NOT operate pump unless additive is completely in solution. Turn pump off
when replenishing solution.
Suction Line
3.5"
(9 cm)
Weighted
Suction Line
Strainer