Classic Series
www.stenner.com
10
FLOW RATE OUTPUTS CLASSIC 100
DUAL CONTROL
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
*
Duckbill check valve included with pumps rated 100 psi (6.9 bar) maximum.
Model
Item Number
Maximum
Pump
Feed Rate Control Setting
Prefix
psi / bar
Tube
L
1
2
3
4
5
6
7
8
9
10
100MDCHP5*
100DH1
100 / 6.9
100MDC1
100DL1
25 / 1.7
100MDCHP20*
100DH2
100 / 6.9
100MDC2
100DL2
25 / 1.7
100MDC3
100DL3
25 / 1.7
3
1.1
2.2
4.4
6.6
8.8
11.0 13.2 15.4 17.6 19.8 22.0
100MDC4
100DL4
25 / 1.7
4
1.7
3.5
7.0
10.5 14.0 17.5 21.0 24.5 28.0 31.5 35.0
100MDC5
100DL5
25 / 1.7
5
2.5
5.0
10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0
Innermost Pump Head – Gallons per Day
2
0.5
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
1
0.2
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
Model
Item Number
Maximum
Pump
Feed Rate Control Setting
Prefix
psi / bar
Tube
L
1
2
3
4
5
6
7
8
9
10
100MDCHP5*
100DH1
100 / 6.9
100MDC1
100DL1
25 / 1.7
100MDCHP20*
100DH2
100 / 6.9
100MDC2
100DL2
25 / 1.7
100MDC3
100DL3
25 / 1.7
3
3.3
6.6
13.3 20.0 26.6 33.3 40.0 46.6 53.3 60.0 66.6
100MDC4
100DL4
25 / 1.7
4
5.1
10.6 21.2 31.8 42.4 53.0 63.6 74.2 84.8 95.4 106.0
100MDC5
100DL5
25 / 1.7
5
7.6
15.1 30.3 45.4 60.6 75.7 90.8 106.0 121.1136.3 151.4
Innermost Pump Head – Liters per Day
2
1.5
3.0
6.1
9.1
12.1 15.1 18.2 21.2 24.2 27.3 30.3
1
0.6
0.9
1.8
2.7
3.6
4.5
5.5
6.4
7.3
8.2
9.1
DETERMINE FLOW RATE OUTPUTS FOR EACH PUMP HEAD
Use the innermost pump head flow rate outputs to determine the output for each pump head.
Both feed rate controls (FRC) on setting 10 = maximum flow rate capacity of the pump.
Innermost Pump Head
L=5%, 1-10 = approx. 10% of maximum innermost output
Outermost Pump Head
Outermost Output = (Outermost FRC Setting %) x (Innermost Output)
Example
100MDC5 with Innermost FRC setting on 4
1. Innermost FRC setting 4 = 20 gpd
2. If outermost FRC is set on 3, then outermost output is 30% of innermost output; 0.3 x 20 gpd = 6 gpd
3. Outermost = 6 gpd, Innermost = 20 gpd, Total Pump Output = 26 gpd