WWW.STEMMER-IMAGING.COM
PP500 LED lighting controllers - User Manual
9
Front panel configuration
Using the front panel keypad, you can set the configuration for each
channel and set a keylock code so unauthorised users cannot change any
settings.
9.1
Startup
On power up, the PP500 displays
br
for five seconds followed by
8.8.8.
to
show that the display is working, then
PP5
and
00
or
00F
, followed by the
firmware version (for example
029
). The controller is then ready for
operation. To show the unit is operating normally, the LED display shows a
pattern of alternating lines.
9.2
Setting the light rating
The Autosense feature detects the presence of a light and prompts you to
set the rating as follows:
When the PP500 detects a light connected to
channel 1 for the first time, Sn1 is displayed. (A
light connected to channel 2 will display Sn2).
When the Cu1 prompt is displayed, press the
SEL button to set the current rating of the light.
Use the
p
and
q
buttons to select the rating of
the light in Amps. The current is adjustable in
steps of 10mA. Press the SEL button when you
have set the current.
—
22
—