FLIGHT MANUAL TSA-M, VARIANT S6
Doc.-No.: P400-006.000 E
Page: 7-24
Revision: 1
Date of Issue: 07. October 2008
Date of Rev.: 28.01.2011
Caution:
The throttle settings of 100% and 115% power can be set
without looking at the throttle. 100% power is set once the
first detent is reached. To set 115% power, the throttle needs
to be pushed past the first detent and against the forward
stop.
7.11.3.2 Choke
Operate the choke of the two carburators with the black lever on the center
console, to the left of the throttle lever. At the carburators a spring pulls the
bowden cable to the CHOKE CLOSED position.
For adjustment the choke lever can be set continuously to the required position
between CHOKE ON (lever rearward) and CHOKE OFF (lever forward).
A preset clamping avoids unintended displacement of choke setting.
When operating the choke, the combustion-mixture is enriched in the starter-
carburator with additional fuel. This is needed for a cold-start of the engine. The
starter-carburator is only operational if the throttle is set to IDLE.
Caution:
Only use the choke briefly when performing a cold-start.
Before T/O it must be set to the CLOSED position again.
Note:
During the daily-check, check to see if the starter-carburator
reaches the stop-position. Also check the operation of the
butterfly-valve on the carburator.
7.11.4 Turbo-Charger and Control-System
The ROTAX 914 F2 engine is equipped with a turbo-charger. It uses the energy
of the exhaust-gas-stream to increase the manifold-air-pressure (MAP). The air-
pressure in the air-box is set with the waste-gate of the turbo-charger-turbine.
The turbo-charger-turbine is controlled by the turbo-control-unit (TCU). The
target-MAP is determined by the setting of the butterfly-valve on the carburator.
The induction of the air is performed through a NACA-inlet on the lower engine-
cowling.