36
PC at barge
Check that it has sufficient air flow and no
dust/dirt in the fan
Gamepad
Keep clean with a damp cloth to prevent the
buttons from sticking. N.B: Not waterproof!
7.2
Larger reparations and modifications
All service must take place at Steinsvik AS or with authorized partners.
Steinsvik AS recommend sending the underwater camera in for service after every generation, while
the winch and PSU can be sent in for service every other generation.
Calibration and/or change of oxygen film on the underwater camera must be sent in to Steinsvik AS
when needed (damage). Estimated lifetime without damage is 5 years.
7.3
Troubleshooting and correction of errors
Table 17 Troubleshooting
Problem
Possible cause
Solution
Winch will not work
Growth on the rope
Remove growth
Winch will not work
Winch rope is jammed
Loosen knots
Winch will not work
Broken winch cable
Check that the cable is whole
and without visible
marks/damages. If the cable is
broken, check for corrections on
contacts on cable and in PSU.
Winch will not work
The camera rope is on the
outside of the circlip
Thread the camera rope to the
inside of the circlip.
Winch will not work
Broken fuse
Check the fuse on the inside of
the PSU and change if this is
broken.
Note:
authorized personnel only
Winch jerks or stops
before reaching the
bottom
Misplaced bottom stop switch
Raise the hoop stopper
7
up and
down to the stop screw. Approx.
5 mm from the bottom position
there should be a “click” from
the switch inside the winch. If
the hoop must be raised 1 cm or
more, the bottom stop switch is
misplaced.
Winch jerks or stops
before reaching the
bottom
Error on the motor protection
on the circuit board.
The motor protection switches
on when the motor is
overloaded, and the winch will
disconnect the motor when the
camera is lifted approx. 1 m
above the water surface. This to
7
Hoop that holds the winch rope up
Summary of Contents for Orbit-200