Version 12.2022
Assembly instructions
67
12 Technical data
When using the STEINEL S-Former E control unit, the limits are automatically detected and set.
When using another control unit, the following limits must be set:
Limits
Motor side
Output side
Rotation speed (1/min)
9 000 / max. 12 000
2 777 / max. 3 703
Peak torque (Nm)
3.703
12
Peak current (A)
10.58
–
The STEINEL S-Former E control unit fulfils all the requirements pertaining to the servo controller’s output
and current.
When using another control unit, ensure that the servo controller in use is able to fulfil the continuous
and peak outputs and currents.
The expected lifetime is dependent on the application, load, ambient conditions,
general handling and maintenance.
The following lifetime specifications are empirical values. They serve for orien-
tation and information and are not obligatory.
Lifetime under optimal usage conditions
AC Servodrive
20 000 h/ 5 years
Ball bearings
20 000 h
Toothed belt stage 1
10 million cycles
Toothed belt stage 2
10 million cycles
Hexagon shaft
10 million cycles
Output hub
5 million cycles
Cylinder
5 million cycles
Valve
5 million cycles