Page 8 of 12
939599284 Rev D
1b
1a
3
5/16" DRILL BIT FOR
FOUR (4) FASTENERS
1/2" DRILL BIT FOR
ETHERNET CABLE
4
5
POWER OVER
ETHERNET CABLE
MIN.
52"
#6-32 SCREW
NUT
media:scape
Mount Kit
Compatibility:
•media:scape or other
structural members.
1.
Position puck on media:scape
a minimum of 52" from floor and
mark four (4) locations to drill for
fasteners (1a) and one (1) location
to drill for cable.
2.
Confirm there are no items that
could pose an interference on the
rearside of the media:scape shroud.
3.
Drill 1/2" dia. hole for power
over ethernet cable and 1/4" dia.
holes for fasteners.
4.
Route power over ethernet
cable through drilled 1/2" dia. hole
in media:scape shroud.
5.
Screw the puck onto the shroud
using the provided four (4) screws
and four (4) washers and four (4)
nuts.
6.
Refer to RoomWizard II
installation quickstart guide for
remaining assembly.
MOUNTING
PUCK
WASHER