Page 7 of 12
939599284 Rev D
RAIL
T-NUT
UNIVERSAL
BRACKET MOUNT
1
2
3
4
SLOT
WASHER
1/4-20
MACHINE
SCREW
Post and Beam
Mount Kit
Compatibility:
•Post and Beam
1.
Align T-nuts with holes
on bottom of universal
bracket mount and loosely
tighten.
2.
Place universal mount
bracket along with T-nuts
onto rail making sure
T-nuts are placed into slot
on rail.
3.
Route power over
ethernet cable through
square hole in bottom of
universal bracket mount.
4.
Tighten the two (2)
provided T-nuts using a
phillips screwdriver.
5.
Perform steps 5,
6a and 6b on page 6.
6.
Refer to RoomWizard II
installation quickstart guide
for remaining assembly.
NOTE:
Do not mount RoomWizard II's so they
protrude into an aisleway.
ADA requires objects projecting from walls with
their leading edges between 27" and 90" (685 mm
and 2030 mm) above the finished floor shall
protrude no more than 4" (100 mm) into walks,
halls, corridors, passageways, or aisles.