background image

Access Requirements

30 

START 
STOP 

TIMER 

TIMER 

 

Alternate Attic Location 

(Insulate to Prevent Freezing) 

Alternate Basement Location 

(Insulated and Dry) 

122 

STOP 

TEMP 

TEMP 

START 

Installation Suggestions

*

 Refer to the Steamist Sizing Guide for actual Cu. Ft. capacity.

- 4 - 

07/07

Pub. No. 324-G

Select  a  location  for  mounting  the  Steam  Generator  that  is 

accessible  for  installation  and  service.  The  access  requirement 

indicates  the  minimum  space  for  convenient  access  to  Steam 

Generator.

CAUTION:

  All  models  must  be  installed  INDOORS,  in  a  DRY, 

NON-FREEZING  location  away  from  flammable  materials  such 

as: Gasoline, Paints, Thinners, Etc...

IMPORTANT:

  Steam  Generator  must  be  installed  upright  and 

level.

SPECIFICATION CHART

6

4

12

240

208

8

8

70

80
40

45

Model

No.

Max. Cu. Ft.

For Area Up To KW

Volt

Phase Amps

Wire Size 90ºC

Copper AWG 

Line

Fuse

SM-12

450

240

208

1

1
3

3

50

58
29

33

SM-15

550

15

240

208
240

208

1

1
3

3

63

72

36

42

4

4
8

6

80

90
45

60

Use 35” with

Optional Auto Drain

35”

28”

20”

18”

Alternate 

Closet  

Location 

Steam 

Generator 

in Vanity 

East Coast Office: 275 Veterans Blvd., Rutherford, NJ 07070 

 Tel: (800) 577-6478 

 Fax: (201) 933-0746

West Coast Office: 315 W. Pondera St., Suite F, Lancaster, CA 93534 

 Tel: (800) 355-6478 

 Fax: (661)940-1617

Summary of Contents for SM-12

Page 1: ...al application or for anything other than a residential steambath installation All electrical connections must be performed by a licensed electrician in accordance with Local and National Electric Codes Steambath Generators C US LISTED 995C The Steamist SM generator operates with one or two controls appropriately located inside and or outside the steamroom It s small enough in size to be tucked aw...

Page 2: ...h selected temperature The proper voltage Steam Generator has been selected i e 208V or 240V A 208V generator operating on 240V will damage the heating element and a 240V Generator operating on 208V will result in a 25 loss of power The Steam Generator is installed in an upright position The proper sized 90 C wire and circuit breaker have been used The circuit breaker is NOT a GFI Ground Fault Int...

Page 3: ...rage rating as required Outside Installation TC 110 or DSP Timer Only Control Cable Route from Control to Steam Generator in a conduit Figure 3 Typical installation Appropriately fuse protected 208 240V field wiring to Steam generator TC 135 DSC 425 and DSP Temperature Control MUST be installed inside the shower Inside Installation Control should be mounted four feet from the floor Select a locati...

Page 4: ...oltage Multi Conductor Cable Typical Steamist Control P14 P12 P11 P16 P15 P10 P1 P2 P6 P8 P7 P9 P4 P3 P5 L H XL P18 P17 DS1 DS2 DS3 DS4 See Chart Test Switch BLU WHT GREY Water Solenoid Valve Terminal Block Optional Auto Drain Valve GRN Heating Elements Water Level Probe Fuse 0 15 AMP SM 12 15 THREE PHASE SCHEMATIC P13 GND Auto Drain Sensor BLU COIL GND BLK BLK BLK YEL BRN ORG ORG BLK BLK RED BLK ...

Page 5: ...n a moist humid area or in an area where parts may freeze or corrode Also do NOT install near flammable materials such as paints thinners gasoline etc The steam line and safety valve reach a temperature of 212 F during operation and should be appropriately protected to prevent personal injury by accidental contact 1 Pre Installation a b c NOTE Safety Valve should be connected to a minimum indirect...

Page 6: ...orm a water tight seal Escutcheon Steamhead Tighten the screw to the steamhead with the screw to face down Installation Instruction for Steamhead Escutcheon 1 2 3 4 5 Be sure the steam pipe is installed with the proper length pipe protruding through the wall Apply silicone sealant around the pipe to seal the pipe to the wall Slip the Escutcheon over the steamhead loosely Screw on the steamhead mak...

Page 7: ...ct waste or as required by Local Codes Outside Installation TC 110 or DSP Timer Only TC 135 DSC 425 and DSP Temperature Control MUST be installed inside the Steam Room WARNING When installing the Steamist Unit in conjunction with an acrylic modular tub shower unit please consult the manufacturer of the module for location of the steamhead Steam Outlet Pipe Use a minimum of a Copper or Brass pipe C...

Page 8: ...alled INDOORS in a DRY NON FREEZING location away from flammable materials such as Gasoline Paints Thinners Etc IMPORTANT Steam Generator must be installed upright and level SPECIFICATION CHART 6 4 12 240 208 8 8 70 80 40 45 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper AWG Line Fuse SM 12 450 240 208 1 1 3 3 50 58 29 33 SM 15 550 15 240 208 240 208 1 1 3 3 63 72 36 42...

Page 9: ...s of two 15 kilowatt Steam Generators therefore reference Specification Chart below Master Slave Interconnection The only common connection between the Master Slave generators is as follows Connect the cable supplied with Slave Unit from Telco receptacle at Slave Unit to same at the Master Unit See diagram on back Control Connection The controls are to be connected to the Master Generator as descr...

Page 10: ... for this application Each generator requires it s own steamhead When a system is purchased you receive 2 steamheads 1 with the control and 1 with the slave generator You must not install these steamheads any closer than 6 Steamheads must be 18 from the finished floor or 6 above the rim of the tub 2 07 07 Pub No 563 C East Coast Office 275 Veterans Blvd Rutherford NJ 07070 Tel 800 577 6478 Fax 201...

Page 11: ... 7 SM 8 SM 11 SM 12 SM 15 System 18 System 24 and System 30 The Steamist InstaMist generators feature pre heat function which provides a generous volume of steam in under a minute This new feature maintains an average water temperature of 180 F in the stainless steel reservior When the steam generator is activated the pre heated water inside the steam generator quickly reaches the boiling point al...

Reviews: