System-30
Steambath Generators
Master/Slave Installation Instructions
Introduction:
The System-30 consists of one SM-15 Master and one
SM-15 Slave. The Master/Slave generators are 15
kilowatts each. This instruction sheet is to be used in
conjunction with the standard SM-15 Electrical and
Plumbing instructions (Pub. No. 323 and 324). All
connections both plumbing and electrical must be kept
completely separate.
Danger:
To reduce the risk of explosion. DO NOT
interconnect the steam outlets.
Operation:
The Master/Slave generators operate as two
completely separate generators. The steam bath controls
are connected to the Master Generator. When the Master
Generator is started up from the controller, it then turns on
the Slave Generator and both units produce steam at the
same time.
NOTE:
The following specifications apply to each of the
two Generators, wired and plumbed separately.
Electrical
Note:
See separate electrical instruction. Pub. No. 323.
Main Power Connection:
Each Steam Generator
requires a separate incoming power service.
Important:
The System-30 consists of two 15 kilowatt
Steam Generators, therefore reference Specification
Chart below.
Master/Slave Interconnection:
The only common
connection between the Master/Slave generators is as
follows: Connect the cable (supplied with Slave Unit) from
Telco receptacle at Slave Unit to same at the Master Unit
(See diagram on back).
Control Connection:
The controls are to be connected to
the Master Generator as described in the control
installation instructions.
Plumbing
Note:
See separate electrical instruction. Pub. No. 324.
Water Connection:
The two Generators may be
connected to a single water line with a tee connection to
the water inlet of each Generator.
Steam Connection:
Each Generator must be connected
to a separate Steamhead using ¾” brass or copper pipe.
Drain Connection:
When the optional drain connection
is made, it must be completely separate from the each
Generator.
Safety Valve Connection:
The Safety Valve must be
connected per the local plumbing code. Then its
connection must be completely separate from each
Generator.
SPECIFICATION CHART
240
208
1
1
2 @ 4
2 @ 4
240
208
3
3
2 @ 63
2 @ 72
2 @ 36
2 @ 42
2 @ 8
2 @ 6
2 @ 80
2 @ 90
2 @ 45
2 @ 60
Max. Cu. Ft.
For Area Up To
KW
Volt
Phase
Amps
Wire Size 90ºC
Copper AWG
Line
Fuse
1100
2 @ 15
C
US
®
LISTED 995C
07/07
Pub. No. 563-C
- 1 -
Slave
Master