IMPORTANT:
Run the Control Cable through a ¾”
conduit. Remove protective cap when making the final
connection to Control.
The Electrical Instructions must be
given to the homeowner for future use.
NOTE:
Unit must be wired with
90°C wire in a suitable raceway,
or, if local codes allow, provide
twist lock plug on a 90°C wire cord
from generator to a 250V 2 pole,
3-wire
grounding
receptacle
(amperage rating as required).
Outside Installation
TC-110 or
DSP Timer Only
Control Cable
Route from
Control to Steam
Generator in a
¾” conduit.
Figure 3: Typical installation
Appropriately
fuse protected
208/240V field
wiring to Steam
generator.
TC-135, DSC-425, and
DSP Temperature Control
MUST
be installed inside
the shower.
Inside Installation
Control should be mounted four
feet from the floor. Select a
location convenient to the
bather but not in a direct line of
Shower or Body Sprays and not
directly above the steamhead.
115
START
STOP
TEMP
TEMP
�
30
START
STOP
TIMER
TIMER
�
07/07
Pub. No. 323-H
- 3 -