05/13

Pub. No. 601-C

- 13 -

Owners Manual

Digital Commercial Control Package Operation

Models: HC-9 thru HC-24 with DCCP Control

     minute OFF mode during an “Off-Peak” daytime 

period. IMPORTANT: Due to possible code violations 
or damage to the building drainage system the hot 
boiling water exiting in this process may require a 
Blow-Down Tank. Consult with your licensed 
contractor. Blow-Down tanks may be purchased 
separately.

8)  Steam Control: The steam valve(s) are controlled 

according to the room temperature sensor(s) and the 
programmed mode. When the room temperature is 
lower than the set temperature by one degree the 
steam valve will turn on. When it reaches the set 
temperature it turns off. If for some reason the room 
temperature exceeds the MAX TEMP setting (of 
either room) by more than 10 degrees the Digital 
Command Center will turn off the generator until that 
room temperature drops to 1 degree below the set 
temperature.   

9)  Aroma Control: There are two aroma control relays 

(one for each room) located in the Command Module 
on the generator. These relays can be used with 
most aroma pumps available.  The relays are 
programmed to conserve aroma therapy oil. The 
relays are only on when the following conditions are 
met. The program for that room must be in the MAX 

mode, the steam valve for that room must be on and 
the temperature in that room must be above the IDLE 
setting. When all these conditions are met, then the 
aroma relays will energize.

10)  Fahrenheit and Celsius: The Fahrenheit or Celsius 

temperature can be selected by changing a jumper in 
the Command Module (CN112). When it is not 
connected (open circuit), it will be Fahrenheit. When it 
is connected, it will be Celsius. The Jumper must be 
switched with power off (See wiring diagram on page 
11).

11)  Reset Feature: If it is ever necessary to reset all the 

programs and start over press and hold the PROG# 
button and the lower MIN button for five seconds 
simultaneously. This will reset every setting in the 
Command Center. This process can also be used to 
unlock the control if the password is lost or forgotten.

Model

No.

Product

No.

KW

Volts/

Phase/

Amps

Shipping

Weight

HC-9

HC-12

HC-15

HC-18

Speci

fi

cations Chart

60900
60901
60902
60903
60904
61200
61201
61202
61203
61204
61500
61501
61502
61503
61504
61800
61801
61802
61803
61804
62400
62401
62402
62403
62404

9

12

15

18

24

Max.

Cu. Ft.

400

500

620

740

1000

240/1/38
208/1/43
240/3/22
208/3/25

480/3/11

240/1/50
208/1/58
240/3/29
208/3/33
480/3/15
240/1/63
208/1/72
240/3/36
208/3/42
480/3/18
240/1/75
208/1/87
240/3/43
208/3/50
480/3/22

240/1/100

208/1/115

240/3/58
208/3/67
480/3/29

Water

Inlet 

Steam

Outlet

Dimensions

21”x19”x25”

21”x19”x25”

21”x19”x25”

21”x19”x25”

21”x19”x25”

140 lbs.

150 lbs.

150 lbs.

150 lbs.

150 lbs.

1/2” NPT

1/2” NPT

1/2” NPT

1/2” NPT

1/2” NPT

3/4” NPT

3/4” NPT

3/4” NPT

3/4” NPT

3/4” NPT

Line

Fuse 

50
60
30
35
15
70
80
40
45
20
80
90
45
60
25

100

110

60
70
30

125
150

80
90
40

HC-24

Summary of Contents for HC-9

Page 1: ... Owners Manual Heavy Commercial Steambath Generator Models HC 9 thru HC 24 with DCCP Control 05 13 Pub No 601 C 1 ...

Page 2: ...ations Warning Sign Figure 1 Access Requirements HC 9 thru HC 24 Figure 2 Dimensional Drawing for HC Steam Generator Figure 3 Typical Steam Generator Installation Figure 4 Overview of Generator Figure 5 Sensor Installation Figure 6 Cables Figure 7 Circuit Board Connections Figure 8 Manager and User Controls Programming Examples Specifications Chart Figure 9 Wiring Diagram Figure 10 Steam head Repo...

Page 3: ...ger should fully understand the causes symptoms and effects of hyperthermia which may be described as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyper...

Page 4: ...Outlet Sight Glass Assembly 17 5 21 12 CONTROL POWER STEAM 2 STEAM 1 24KW 208V ASME Data Plate 19 6 2 Steam Valves may be rotated by loosening this union Power Switch Steam Solenoid Switches Shown with optional 2nd control package Heater Access ASME Plate Located Inside 1 Manual Drain Valve 1 Optional Auto Blowdown Valve Control Access Access Shown with optional 2nd control package Steam Outlet 2 ...

Page 5: ...nit purchased is sized adequately for your steam room B Be sure to have the proper electrical supply Determine proper size of wire voltage amperage and phase for the steam generator based on the specification plate attached to the generator and the chart in the back of this manual C Provide an inline fuse circuit breaker as required sized in accordance with specification chart Do not install a GFI...

Page 6: ...from a cold water supply Provide a local shut off valve 2 Rough in the steam line using 3 4 copper tubing Do NOT use iron or galvanized pipe it will rust and discolor wall of steam room For a steam line that is longer than 10 feet use an appropriate pipe insula tion rated for a minimum of 250ºF The steam head should be located approximately 18 above the floor and as far from the bather as possible...

Page 7: ...lenoid is piped to the proper room 3 Safety Line Connect the 3 4 NPT safety valve into the previously installed indirect waste line 4 Optional automatic blow down Pipe into the 1 indirect waste line 5 For steam head installation see Page 15 6 The steam safety and drain pipes become hot during operation and should be insulated with appropriate rated pipe insulation to protect against accidental con...

Page 8: ... pumps will all be labeled for room 1 and room 2 It is very important to pay attention not get the connection to room 1 and room 2 crossed If the generator is configured for one room there will not be any special markings B USER BYPASS CONTROL s The USER BYPASS CONTROL should be located outside the steam room door convenient to the bather This control gives the bather limited control of the steam ...

Page 9: ...ons do not function When the DIGITAL COMMAND CENTER is in the OFF mode the USER BYPASS CONTROL icon will be off no bars lit and the user buttons do not function B Programming the DIGITAL COMMAND CENTER can be broken down into 3 separate sections SET EVENT SET VALUE and SET CLOCK The buttons on the control are grouped accordingly SET EVENT is used to set the time and day that a particular mode MAX ...

Page 10: ...on the Digital Command Center Each time the button is pressed the minutes will increase in one minute increments from 00 to 60 If the MAX CYCLE TIMER is programmed to 00 this feature will be disabled and the USER BYPASS CONTROL S will be disabled e Degree C or F change is made by placing a jumper over the CN112 pins for C or by removing it for F Jumper not included The power must be OFF when makin...

Page 11: ...ram At any time the system is in IDLE mode the user can activate the MAX TEMP mode by pressing the USER BYPASS CONTROL button Photo copy the chart and use it as a work sheet to plan you settings Models HC 9 thru HC 24 with DCCP Control PROG 1 2 3 4 5 6 EXAMPLE 1 MAX IDLE OFF X X X X X X TIME 12 00AM 8 00AM 10 00AM 3 00PM 7 00PM 10 00PM PROG 1 2 3 4 5 6 EXAMPLE 2 MAX IDLE OFF X X TIME 12 00AM 8 00A...

Page 12: ...ime settings If you made no changes simply press the enter button to return to normal or it will return in 30 seconds d Programming Tip When reviewing the program and a block of days are selected if all the individual programs for those days do not match the clock will display This is normal and any adjustments made at this time will reprogram all days selected to match the new entry 5 Manager loc...

Page 13: ...be above the IDLE setting When all these conditions are met then the aroma relays will energize 10 Fahrenheit and Celsius The Fahrenheit or Celsius temperature can be selected by changing a jumper in the Command Module CN112 When it is not connected open circuit it will be Fahrenheit When it is connected it will be Celsius The Jumper must be switched with power off See wiring diagram on page 11 11...

Page 14: ...team Switch 2 Steam Switch 1 M G 120V N 15AMP Branch Circuit Aroma Light Note All factory wires are 18AWG unless otherwise noted Power and heater wire gauge are set by the factory Note CN112 Jumper open Fº Jumper 2 to 3 Cº Turn off power to make this change reset CN112 F3 Light Note Select BL for 240V RD for 208V BK RD BN BL VT VT PROBE 14WT 12GN 14YL 14BN RD GY WT 12GN OR OR YL YL RD BK BK BK RD ...

Page 15: ...he location of the steam head necessitate blocking the steam from a particular direction to improve bather comfort the supplied deflector plate can be added to any of the three sides shown to help divert the steam away from the bather The deflector is attached to the back side of the head before installation with 2 stainless steel screws provided 1 Make sure the 3 4 nipple protrudes beyond the til...

Page 16: ...only to the original purchaser who shall have been named in the Registration of Warranty This warranty is void if any of the following should occur 1 If the serial number has been altered or removed 2 If the product is modified in any manner which STEAMIST concludes after inspection affects the reliability of the product 3 If the product has been repaired or serviced by anyone not specifically des...

Reviews: