Owners Manual
Digital Commercial Control Package Operation
Models: HC-9 thru HC-24 with DCCP Control
minute OFF mode during an “Off-Peak” daytime
period. IMPORTANT: Due to possible code violations
or damage to the building drainage system the hot
boiling water exiting in this process may require a
Blow-Down Tank. Consult with your licensed
contractor. Blow-Down tanks may be purchased
separately.
8) Steam Control: The steam valve(s) are controlled
according to the room temperature sensor(s) and the
programmed mode. When the room temperature is
lower than the set temperature by one degree the
steam valve will turn on. When it reaches the set
temperature it turns off. If for some reason the room
temperature exceeds the MAX TEMP setting (of
either room) by more than 10 degrees the Digital
Command Center will turn off the generator until that
room temperature drops to 1 degree below the set
temperature.
9) Aroma Control: There are two aroma control relays
(one for each room) located in the Command Module
on the generator. These relays can be used with
most aroma pumps available. The relays are
programmed to conserve aroma therapy oil. The
relays are only on when the following conditions are
met. The program for that room must be in the MAX
mode, the steam valve for that room must be on and
the temperature in that room must be above the IDLE
setting. When all these conditions are met, then the
aroma relays will energize.
10) Fahrenheit and Celsius: The Fahrenheit or Celsius
temperature can be selected by changing a jumper in
the Command Module (CN112). When it is not
connected (open circuit), it will be Fahrenheit. When it
is connected, it will be Celsius. The Jumper must be
switched with power off (See wiring diagram on page
11).
11) Reset Feature: If it is ever necessary to reset all the
programs and start over press and hold the PROG#
button and the lower MIN button for five seconds
simultaneously. This will reset every setting in the
Command Center. This process can also be used to
unlock the control if the password is lost or forgotten.
Model
No.
Product
No.
KW
Volts/
Phase/
Amps
Shipping
Weight
HC-9
HC-12
HC-15
HC-18
Speci
fi
cations Chart
60900
60901
60902
60903
60904
61200
61201
61202
61203
61204
61500
61501
61502
61503
61504
61800
61801
61802
61803
61804
62400
62401
62402
62403
62404
9
12
15
18
24
Max.
Cu. Ft.
400
500
620
740
1000
240/1/38
208/1/43
240/3/22
208/3/25
480/3/11
240/1/50
208/1/58
240/3/29
208/3/33
480/3/15
240/1/63
208/1/72
240/3/36
208/3/42
480/3/18
240/1/75
208/1/87
240/3/43
208/3/50
480/3/22
240/1/100
208/1/115
240/3/58
208/3/67
480/3/29
Water
Inlet
Steam
Outlet
Dimensions
21”x19”x25”
21”x19”x25”
21”x19”x25”
21”x19”x25”
21”x19”x25”
140 lbs.
150 lbs.
150 lbs.
150 lbs.
150 lbs.
1/2” NPT
1/2” NPT
1/2” NPT
1/2” NPT
1/2” NPT
3/4” NPT
3/4” NPT
3/4” NPT
3/4” NPT
3/4” NPT
Line
Fuse
50
60
30
35
15
70
80
40
45
20
80
90
45
60
25
100
110
60
70
30
125
150
80
90
40
HC-24