压接

Crimping

(ill. 7) 

 

打开夹钳(K)并保持。 

 

将触子置于适当的横截面范围内。 

 

向上旋转压接片。

 

松开夹钳 (K)。 

 

触子已被固定。

(ill. 7) 

 

Open and hold the clamp (K) � 

 

Place the contact in the appropriate 

cross-section range� 

 

Turn the crimping flaps upwards�

 

Release clamp (K)� 

 

The contact is fixed�

 

注意(图 8):

 

确保触头置于外壳内,并以夹子固

定。

 

Note (ill. 8):

 

Make sure that the contact is 

placed in the housing and is held by 

the clamp�

(ill. 9) 

轻轻按压钳子,直到将压接片正确嵌入

压接模具。

(ill. 9) 

Press the pliers gently together until 

the crimping flaps are properly located 

within the the crimping die�

(ill. 10) 

插入剥皮后的电缆末端,使电缆导线与

定位块接触。完全合上压接钳。

(ill. 10) 

Insert the stripped cable end until the 

cable strands come up against the 

locator� Completely close the crimping 

pliers�

(ill 11)

检查压接处。

(ill 11)

Check the crimping�

Summary of Contents for PV-ADB4-EV0 2/2,5-UR

Page 1: ...UR PV Female panel receptacle PV ADB4 EVO 2 UR PV Male panel receptacle PV ADS4 EVO 2 UR 2 4 5 6 7 8 9 10 11 12 Content Safety Instructions 2 4 Tools required 5 Cable preparation 6 Crimping 7 Installa...

Page 2: ...trical connec tion with long term stability and for safety reasons must not be plugged together with St ubli elements St ubli therefore does not accept any liability for any damages resulting from mat...

Page 3: ...levant standards to which they have been evaluated and certified 3 2 0 1 7 6 32 0717 Unmated plug connectors must be protected from moisture and dirt with a sealing cap 32 0716 for sockets and 32 0717...

Page 4: ...onnectors The PV connector shall only be used on photovoltaic power con vertors or photovoltaic generators e g photovoltaic modules and their contacts and field wiring Application is only permitted wi...

Page 5: ...ructions MA251 www staubli com electrical ill 3 PV MS PLS 1 2 32 6058 ill 3 Assembly and unlocking tool PV MS PLS 1 Set 2 pcs Order No 32 6058 MA270 www staubli com electrical Note Operating instructi...

Page 6: ...th ill 5 and Tab 1 b b Control dimension Conductor cross section Type mm mm2 AWG 3 2 5 14 PV ADB4 EVO 2 2 5 UR PV ADS4 EVO 2 2 5 UR 5 4 6 12 10 PV ADB4 EVO 2 6 UR PV ADS4 EVO 2 6 UR Tab 1 ill 6 6 0 7...

Page 7: ...act is fixed 8 Note ill 8 Make sure that the contact is placed in the housing and is held by the clamp ill 9 ill 9 Press the pliers gently together until the crimping flaps are properly located within...

Page 8: ...t be located on the insulation IP65 IP68 Danger In case of lacking flat gasket or incorrect mounting the ingress protection IP65 and IP68 will be compromised ill 14 ill 14 E M 1 7 Nm1 Note Position th...

Page 9: ...l recep tacles are mounted IEC 62852 POS NEG POSITIVE NEGATIVE Note According to IEC 62852 following markings are considered as a clear labeling of the polarity and POS and NEG POSITIVE and NEGATIVE P...

Page 10: ...AWG 42 A 4 0 mm 12 AWG 47 A 6 0 mm 10 AWG Ambient temperature range 40 C 85 C IEC 40 C 90 C UL Upper limiting temperature 115 C Degree of protection mated unmated IP65 IP68 1m 1h IP2X Overvoltage cat...

Page 11: ...11 12 11 12 Notes...

Page 12: ...ckbrunnenrain 8 4123 Allschwil Switzerland Tel 41 61 306 55 55 Fax 41 61 306 55 56 mail ec ch staubli com www staubli com electrical by St ubli Electrical Connectors AG Switzerland MA285 10 2020 Index...

Reviews: