存放须知

Note on storage

我们建议将连接器部件存放在温度-30°C 至 60°C,相对湿度小于

70%的环境中。

部件不能暴露在因降雨、霜降等造成的潮湿环境中。确保单个部

件不与酸、碱、汽油、丙酮或其他任何可能影响材质的化学物质接

触。

满足以上条件,则部件自出厂之日起最多可存放两年。

We recommend that you store connector components at a tem-

perature between -30°C and +60°C and with a relative humidity 

of less than 70%�

The components must not be exposed to moisture due to direct 

rainfall, condensation, etc� Ensure that the individual components 

do not come into contact with acids, alkalis, gases, acetone, or 

any other chemical substances that could impact the materials 

used�

If these conditions are met, the components can be stored for a 

maximum period of up to two years from the date of manufac-

ture�

应用范围

Intended use

光伏连接器及相应工具的预期应用是安全应用及在技术上正确

装配连接器的基本要求。

光伏连接器应仅用于光伏电源转换器或光伏发电机(如光伏组件

及其连接点和现场接线)。只允许在第  1  页所述的技术规格内应

用。只允许合格且经验丰富的人员使用  Stäubli  发放的工具进行

装配和应用,同时应考虑此装配说明、安装标准  DIN  VDE-0100-

712 (IEC 60364-7-712) 以及国家及国际安全法规。

The intended application of the PV-connector and the corre-

sponding tools is the basic requirement for a safe application and 

technically correct assembled connectors�

The PV-connector shall only be used on photovoltaic power con-

vertors or photovoltaic generators (e�g� photovoltaic modules 

and their contacts and field wiring)� Application is only permitted 

within the technical specifications� 

Assembly and application is only permitted by electrically skilled 

or instructed persons with tools which have been released by 

Stäubli, taking this assembly instruction into consideration as well 

as the installation standard DIN VDE-0100-712 (IEC 60364-7-

712) and all national and international safety legislations�

非恰当使用举例

Examples of unintended use

 

未遵守安全规则

 

未遵守装配说明的安全说明

 

使用非 Stäubli 制造或认可的连接器

 

Failure to observe safety regulations

 

Failure to observe the safety instructions of these assembly 

instructions

 

Use of plug connectors not made or approved by Stäubli

非恰当使用的危害

Dangers of unintended use

 

触电导致人员受伤

 

电弧导致失明或严重危险

 

Injury to persons as a result of electric shock

 

Blindness and or fire hazard due to arcing

注意

Note

使用者有责任穿着合适的防护装备工作

The wearing of suitable personal protective equipment (PPE) is in 

the responsibility of the user�

Summary of Contents for PV-ADB4-EV0 2/2,5-UR

Page 1: ...UR PV Female panel receptacle PV ADB4 EVO 2 UR PV Male panel receptacle PV ADS4 EVO 2 UR 2 4 5 6 7 8 9 10 11 12 Content Safety Instructions 2 4 Tools required 5 Cable preparation 6 Crimping 7 Installa...

Page 2: ...trical connec tion with long term stability and for safety reasons must not be plugged together with St ubli elements St ubli therefore does not accept any liability for any damages resulting from mat...

Page 3: ...levant standards to which they have been evaluated and certified 3 2 0 1 7 6 32 0717 Unmated plug connectors must be protected from moisture and dirt with a sealing cap 32 0716 for sockets and 32 0717...

Page 4: ...onnectors The PV connector shall only be used on photovoltaic power con vertors or photovoltaic generators e g photovoltaic modules and their contacts and field wiring Application is only permitted wi...

Page 5: ...ructions MA251 www staubli com electrical ill 3 PV MS PLS 1 2 32 6058 ill 3 Assembly and unlocking tool PV MS PLS 1 Set 2 pcs Order No 32 6058 MA270 www staubli com electrical Note Operating instructi...

Page 6: ...th ill 5 and Tab 1 b b Control dimension Conductor cross section Type mm mm2 AWG 3 2 5 14 PV ADB4 EVO 2 2 5 UR PV ADS4 EVO 2 2 5 UR 5 4 6 12 10 PV ADB4 EVO 2 6 UR PV ADS4 EVO 2 6 UR Tab 1 ill 6 6 0 7...

Page 7: ...act is fixed 8 Note ill 8 Make sure that the contact is placed in the housing and is held by the clamp ill 9 ill 9 Press the pliers gently together until the crimping flaps are properly located within...

Page 8: ...t be located on the insulation IP65 IP68 Danger In case of lacking flat gasket or incorrect mounting the ingress protection IP65 and IP68 will be compromised ill 14 ill 14 E M 1 7 Nm1 Note Position th...

Page 9: ...l recep tacles are mounted IEC 62852 POS NEG POSITIVE NEGATIVE Note According to IEC 62852 following markings are considered as a clear labeling of the polarity and POS and NEG POSITIVE and NEGATIVE P...

Page 10: ...AWG 42 A 4 0 mm 12 AWG 47 A 6 0 mm 10 AWG Ambient temperature range 40 C 85 C IEC 40 C 90 C UL Upper limiting temperature 115 C Degree of protection mated unmated IP65 IP68 1m 1h IP2X Overvoltage cat...

Page 11: ...11 12 11 12 Notes...

Page 12: ...ckbrunnenrain 8 4123 Allschwil Switzerland Tel 41 61 306 55 55 Fax 41 61 306 55 56 mail ec ch staubli com www staubli com electrical by St ubli Electrical Connectors AG Switzerland MA285 10 2020 Index...

Reviews: