安全指令

Safety instructions

   ISO  7000-0434B   

注意

 Caution

每次使用连接器前,需提前检查外部是否有缺陷(尤其是绝缘层)

如有安全疑虑,必须咨询专业人员或更换连接器。

Each time the connector is used, it should previously be inspect-

ed for external defects (particularly the insulation)� If there are any 

doubts as to its safety, a specialist must be consulted or the 

connector must be replaced�

连接器的防水功能可参考相关产品的IP保护等级。但是,它们不

适合长期在水下使用。

请勿将连接器直接置于屋顶防水层。

The plug connectors are watertight in accordance with the prod-

uct specific IP protection class� However, they are not suitable 

for continuous operation under water� Do not place the plug con-

nectors directly on the roof membrane�

所述额定电压为最大电压值,且仅适于电缆连接器。电缆线束的

最终额定电压取决于部件中最低的最大额定电压,以及对其进

行评估和认证的相关标准。

Stated voltage ratings are maximum values and pertain only to 

the cable couplers� The final voltage rating of a cable lead assem-

bly or harness is dictated by the lowest maximum voltage rating 

of any component contained in the assembly and the relevant 

standards to which they have been evaluated and certified�

未 插 合 状 态 的 连 接 器 必 须 使 用 密 封 盖(3 2  0 1 7 6 用 于 插

座,320717用于插头)防潮防尘。被污染的公母连接器不应插合

使用。

Unmated plug connectors must be protected from moisture and 

dirt with a sealing cap (32�0716 for sockets and 32�0717 for 

plugs)� The male and female parts must not be plugged together 

when soiled�

部件不得承受永久性机械拉伸载荷。根据本地电气规范与标准,

电缆应使用扎带固定。

The components must never be subjected to a permanent me-

chanical tensile load� The cable should be fastened with cable 

ties according to the local Electrical Code standards and norms�

务必遵守规定的安装位置。

The defined mounting position must be complied with�

确认使用正确的编码。

Be sure to use the right coding for your application�

部件和包装材料并非玩具;若吞食小零件可能有窒息危险。包装

材料有造成窒息的危险。

Components and packaging materials are not toys; small parts 

can pose a choking hazard if swallowed� Packaging material can 

pose a risk of suffocation�

产品使用须严格依照技术参数中给出的规范(例如提供充分的

背部通风以确保连接器处于正常的工作温度范围)。

Use only in accordance with the specification provided in the 

technical data (e�g� compliance with approved temperatures by 

providing sufficient back ventilation)�

 

 产品使用说明或技巧

 

Useful hint or tip

更多技术参数请见产品目录。

For further technical data please see the product catalog�

Summary of Contents for PV-ADB4-EV0 2/2,5-UR

Page 1: ...UR PV Female panel receptacle PV ADB4 EVO 2 UR PV Male panel receptacle PV ADS4 EVO 2 UR 2 4 5 6 7 8 9 10 11 12 Content Safety Instructions 2 4 Tools required 5 Cable preparation 6 Crimping 7 Installa...

Page 2: ...trical connec tion with long term stability and for safety reasons must not be plugged together with St ubli elements St ubli therefore does not accept any liability for any damages resulting from mat...

Page 3: ...levant standards to which they have been evaluated and certified 3 2 0 1 7 6 32 0717 Unmated plug connectors must be protected from moisture and dirt with a sealing cap 32 0716 for sockets and 32 0717...

Page 4: ...onnectors The PV connector shall only be used on photovoltaic power con vertors or photovoltaic generators e g photovoltaic modules and their contacts and field wiring Application is only permitted wi...

Page 5: ...ructions MA251 www staubli com electrical ill 3 PV MS PLS 1 2 32 6058 ill 3 Assembly and unlocking tool PV MS PLS 1 Set 2 pcs Order No 32 6058 MA270 www staubli com electrical Note Operating instructi...

Page 6: ...th ill 5 and Tab 1 b b Control dimension Conductor cross section Type mm mm2 AWG 3 2 5 14 PV ADB4 EVO 2 2 5 UR PV ADS4 EVO 2 2 5 UR 5 4 6 12 10 PV ADB4 EVO 2 6 UR PV ADS4 EVO 2 6 UR Tab 1 ill 6 6 0 7...

Page 7: ...act is fixed 8 Note ill 8 Make sure that the contact is placed in the housing and is held by the clamp ill 9 ill 9 Press the pliers gently together until the crimping flaps are properly located within...

Page 8: ...t be located on the insulation IP65 IP68 Danger In case of lacking flat gasket or incorrect mounting the ingress protection IP65 and IP68 will be compromised ill 14 ill 14 E M 1 7 Nm1 Note Position th...

Page 9: ...l recep tacles are mounted IEC 62852 POS NEG POSITIVE NEGATIVE Note According to IEC 62852 following markings are considered as a clear labeling of the polarity and POS and NEG POSITIVE and NEGATIVE P...

Page 10: ...AWG 42 A 4 0 mm 12 AWG 47 A 6 0 mm 10 AWG Ambient temperature range 40 C 85 C IEC 40 C 90 C UL Upper limiting temperature 115 C Degree of protection mated unmated IP65 IP68 1m 1h IP2X Overvoltage cat...

Page 11: ...11 12 11 12 Notes...

Page 12: ...ckbrunnenrain 8 4123 Allschwil Switzerland Tel 41 61 306 55 55 Fax 41 61 306 55 56 mail ec ch staubli com www staubli com electrical by St ubli Electrical Connectors AG Switzerland MA285 10 2020 Index...

Reviews: