background image

39

limited warranty

State Industries, Inc., the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater.

1.  THE TANK
 

If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, 

during the first THREE years after initial installation, the warrantor will supply a complete new State water heater of equivalent size and current model.  

Some government agencies are requiring energy efficient standards for water heaters. In the event regulations prohibit sale of a model of equivalent size 

and construction, State Water Heaters will provide a model which complies with the regulations of your area, in which case the consumer will be charged 

the difference in price between the like replacement and the energy efficient model required. The warranty on the replacement water heater will be limited 

to the unexpired term of the original warranty.

2.  ALL OTHER PARTS
  If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in material 

or workmanship, the warrantor will repair or replace such part or portion at its option.

3.  CONDITIONS AND EXCEPTIONS
  This warranty shall apply only when the water heater is installed in accordance with local plumbing and building codes, ordinances and regulations, the 

printed instructions provided with it and good industry practices.  In addition, a temperature and pressure relief valve, certified by and officially sanctioned 

and recognized independent testing agency and approved by the American Society of Mechanical Engineers, must have been installed.

  a.  This warranty shall apply only when the heater is:

   

(1) used at temperatures not exceeding the maximum calibrated setting of its thermostat;

   

(2) used at water pressure not exceeding the working pressure shown on the heater;

   

(3) filled with potable water, free to circulate at all times and with the tank free of damaging water sediment or scale deposits;

   

(4) used in a non-corrosive and non-contaminated atmosphere;

   

(5) used with factory approved anode(s) installed;

   

(6) in its original installation location;

   

(7) in the United States, its territories or possessions or Canada;

   

(8) sized in accordance with proper sizing techniques for commercial and/or residential water heaters;

   

(9) bearing a rating plate which has not been altered, defaced or removed, except as required by the warrantor;

   

(10) used in an open system or in a closed system with properly sized and installed thermal expansion tank;

   

(11) operated with properly installed dirt leg;

   

(12) fired with the fuel for which it was factory built;

   

(13) fired at the factory rated input;

   

(14) operated with the inner and outer combustion chamber doors in place.

  b.  Any accident to the water heater, any misuse, abuse (including freezing or thermal expansion damage) or alteration of, any operation in a modified form, 

or any attempt to repair tank leaks will void this warranty.

  c.  This warranty is void if a device acting as a backflow prevention device (check valves etc.) is installed in the cold water supply the heater is connected 

to, unless an effective method of controlling thermal expansion is also installed at the heater(s) and operational at all times.  The relief valve installed 

on the heater is not an acceptable method.

4.  SERVICE AND REPAIR EXPENSES
  Under the limited warranty the warrantor will provide only a replacement water heater or part thereof.  The owner is responsible for all other costs.   Such 

costs may include but are not limited to:

  a.  Labor charges for service removal, repair or reinstallation of the water heater or any component part;

  b.  Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest distributor and returning 

the claimed defective heater or part to such distributor.

  c.  All cost necessary or incidental for any material and/or permits required for installation of the replacement heater or part.
5.  LIMITATIONS ON IMPLIED WARRANTIES
  Implied warranties, including the warranty of merchantability imposed on the sale of this heater under state law or local code are limited to one (1) year duration 

for the heater or any of its parts.  Some areas do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

6.  CLAIM PROCEDURE
  Any claim under the warranty should be initiated with the dealer who sold the heater, or with any other dealer handling the warrantor’s products.  If this is 

not practicable, the owner should contact:

 

u.s. customers 

canadian customers

 

A. O. Smith Corporation 

A. O. Smith Enterprises Ltd.

 

500 Tennessee Waltz Parkway 

P. O. Box, 310 - 768 Erie Street

 

Ashland City, TN 37015 

Stratford (Ontario)  N5A 6T3

 

Telephone: 1-(800)-323-2636 

Telephone: 1-(800) 265-8520

 

a.  The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the warrantor.

  b.  Dealer replacements are made subject to in-warranty validation by warrantor.
7. DISCLAIMERS
 

NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY OF 

THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE HEATER.  THE WARRANTOR SHALL NOT BE RESPONSIBLE 

FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER CONSEQUENTIAL 

DAMAGE.  THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS OR 

PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING IN CONTRACT OR IN TORT.

 

a.  Some areas do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may not apply to you.

  b.  This warranty gives you specific legal rights, and you may also have other rights which vary from area to area.

Fill in the following for your own reference.  Keep it. Registration is not a condition of warranty.  The model and serial number are found on the heater’s rating plate.
Model No. ________________________________ Serial No. _______________________________ Date Installed ________________________________
Dealer’s Name _________________________________________________________________________________________________________________
Dealer’s Address _________________________________________________________________________ Phone No._____________________________
City and State __________________________________________________________________________ Zip ___________________________________

KEEP THIS WARRANTY POSTED ADJACENT TO THE HEATER FOR FUTURE REFERENCE.

Summary of Contents for SHE 50 76N

Page 1: ...L AND WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOU ARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEA...

Page 2: ...alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage WARNING CAUTION CAUTION DANGER All safety messages will generally tell you about the type...

Page 3: ...3 GENERAL SAFETY INFORMATION...

Page 4: ...4 GENERAL SAFETY INFORMATION at least 18 45 7cm above the floor This will reduce but not eliminate the risk...

Page 5: ...ilablefromNational Fire Protection Association 1 Batterymarch Park Quincy MA 02269 3 The water heater when installed must be grounded in accordance with the local codes or in the absence of local code...

Page 6: ...feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch...

Page 7: ...Exhaust Tee GG Elbow GET TO KNOW YOUR WATER HEATER GAS MODELS A Vent Pipe B Anode C Hot Water Outlet D Outlet 120 VAC F Gas Supply G Main Manual Gas Shut Off Valve H Ground Joint Union J Dirt Leg K O...

Page 8: ...8 TYPICAL INSTALLATION CONDENSATE HOSE AND DRAIN PAN FIGURE 1 continued...

Page 9: ...ship for normal adult skin If anyone using hot water provided by the water heater being installed fits into one of these groups or if there is a local code or state law requiring a certain water tempe...

Page 10: ...cs All models Maximum Supply Pressure 14 inches W C 3 48kPa Minimum Supply Pressure Natural Gas 5 0 inches W C 1 24kPa Minimum Pressure must be maintained under both load and no load static and dynami...

Page 11: ...talled in locations where leakage may result in property damage even with the use of a drain pan piped to a drain However unanticipated damage can be reduced or prevented by a leak detector or water s...

Page 12: ...rine based chemicals refrigerants etc in addition to being highly flammable in many cases will also react to form corrosive hydrochloric acid when exposed to the combustion products of the water heate...

Page 13: ...e the size of openings providing fresh air into confined spaces EXHAUST FANS Where exhaust fans are installed additional air shall be provided to replace the exhausted air When an exhaust fan is insta...

Page 14: ...a reference for the openings that provide fresh air into confined spaces only Do not refer to these illustrations for the purpose of vent installation See Installation of Vent System on pages 20 21 fo...

Page 15: ...f code requirements or such conditions as high line pressure among others have installed devices such as pressure reducing valves check valves and back flow preventers Devices such as these cause the...

Page 16: ...the T P valve Secure all insulation using tape Temperature Pressure Relief Valve Explosion Hazard Temperature Pressure Relief Valve must comply with ANSI Z21 22 CSA 4 4 and ASME code Properly sized T...

Page 17: ...T P valve is not intended for the constant relief of thermal expansion Aproperly sized thermal expansion tank must be installed on all closed systems to control thermal expansion see Closed Water Syst...

Page 18: ...system by closing itsindividualmanualShut offvalveduringanypressuretestingofthegas supply piping system at test pressures equal to or less than 1 2 pound per square inch 3 5 kPa Connecting gas piping...

Page 19: ...uctions Assemble Vent Pipe Assemblies 1 2 and 3 See Figure 1 prior to cementing The preferred orientation of Vent Pipe Assembly 1 Condensate U Assembly is shown in Figure 16 However this assembly may...

Page 20: ...0 cm 12 inches 30 cm K Clearance to a mechanical air supply inlet 6 feet 1 83 m 3 feet 91 cm above if within 10 feet 3 m horizontally E Clearance to unventilated soffit 12 inches 30 cm 12 inches 30 cm...

Page 21: ...ectmaterialasdetailedabovehasbeenused andthatminimum ormaximumventlengthsandterminallocationasdetailedinthismanual have been met Carefully inspect entire venting system for any signs of cracks or frac...

Page 22: ...that the plastic tubing is still attached from the air pressure switch to the port on the blower housing Make sure the plastic tubing is not folded anywhere between the pressure switch and the blower...

Page 23: ...ine This will allow the vent to easily slide through the opening The resulting gap will be covered up by the Vent Terminal cover plate Repeat this step on inside wall if necessary SEQUENCE OF INSTALLA...

Page 24: ...ighest anticipated snow level install a snorkel as shown in bottom portion of Figure 20 NOTE With the installation of a snorkel it is necessary to use two 90 elbows that shall be considered along with...

Page 25: ...cement not included with kit and glue the two inch PVC pipe coming from the blower into the VAA 3 Perform the same sequence on the PVC pipe coming from the exhaust side vent terminal side of the VAA...

Page 26: ...and the vent pipe system Air leaks will allow flue gas by products to disseminate into the room creating an unsafe environment and could cause illness asphyxiation and or even death FIGURE 24 Typical...

Page 27: ...and above PRIMER It is recommended that Tetrahydrofuran THF be used to prepare the surfaces of pipe and fittings for solvent welding Do not use water rags gasoline or any other substitutes for cleanin...

Page 28: ...make a second mark as the primer and cement will most likely destroy your first one Apply primer to the surface of the pipe and fitting socket with a natural bristle brush This process softens and pr...

Page 29: ...R buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Turn off all ele...

Page 30: ...c does not have access If a suitable area is not available a cover should be installed over the thermostat to prevent tampering Thewatertemperaturesettingwasfactorysetatthelowesttemperature Pressing t...

Page 31: ...cal water heater supplier or service agency for further information concerning an Anode Replacement Kit and this chlorination treatment If the smelly water persists after the anode replacement and chl...

Page 32: ...uld be made of the main burner and the hot surface igniter assembly for proper flame characteristics and ignition sequences This can be done by removing the Outer Door and viewing the main burner oper...

Page 33: ...ve a thermal expansion tank installed is not covered under the limited warranty Thermal expansion tanks must be installed on all closed water systems DO NOT PLUG THE TEMPERATURE PRESSURE RELIEF VALVE...

Page 34: ...ose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances wat...

Page 35: ...control does not energize the blower replace the Intelli Vent control If the blower fails to Blower may run continuously in start when energized replace the blower assembly this condition 2 Ensure the...

Page 36: ...ff for 10 20 seconds then on again to clear this error code 4 Ensure the flame sensor is clean use ultra fine steel wool or Scotch Brite pad to clean flame sensor 5 Ensure the hot surface ignitor is p...

Page 37: ...in tolerance 1 Ensure air pressure switch hose is not kinked or clogged ensure the blower housing is clear of any condensation 2 Check vent temperature limit switch if it is determined that the vent t...

Page 38: ...38 These guidelines should be utilized by a qualified service agent TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES...

Page 39: ...installed at the heater s and operational at all times The relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES Under the limited warranty the warrantor will...

Page 40: ...www statewaterheaters com 500 Tennessee Waltz Parkway Ashland City TN 37015 Technical Support 800 365 0024 Parts 800 821 2017...

Reviews: