vent pIpe preparatIon

1. 

InItIal preparatIon

  A.   Make sure the solvent cement you are planning to use is 

designed for the specific application you are attempting.

 

B.  Know the physical and chemical characteristics and limitations of 

the PVC and CPVC piping materials that you are about to use.

  C.  Know the reputation of your manufacturer and their products.

  D.  Know your own qualifications or those of your contractor. The 

solvent welding technique of joining PVC and CPVC pipe is a 

specialized skill just as any other pipe fitting technique.

  E.  Closely supervise the installation and inspect the finished  

job before start-up.

 

F.  Contact the manufacturer, supplier, or competent consulting 

agency if you have any questions about the application or 

installation of PVC and CPVC pipe.

  G.  Take the time and effort to do a professional job.  

Shortcuts will only cause you problems and delays in 

start-up.  By far, the majority of failures in PVC and CPVC 

systems are the result of shortcuts and/or improper 

joining techniques.

2. 

selectIon of MaterIals

•  Cutting Device - Saw or Pipe Cutter
•  Deburring Tool, Knife, File, or Beveling Machine (2” and above)
•  Brush - Pure Bristle
•  Rag - Cotton (Not Synthetic)
•  Primer and Cleaner
•  Solvent  Cement  -  PVC  for  PVC  Components  and  CPVC  for    

CPVC Components

•  Containers - Metal or Glass to hold Primer and Cement.  Select  

the type of PVC or CPVC materials to be used on the basis of 

their application with respect to chemical resistance, pressure 

rating, temperature characteristics, etc.

•    Insertion Tool  -  Helpful  for  larger  diameter  pipe  and  fittings  6 

inches (15.2 cm) and above.

prIMer

It is recommended that Tetrahydrofuran (THF) be used to prepare the 

surfaces of pipe and fittings for solvent welding. Do not use water, 

rags, gasoline or any other substitutes for cleaning PVC or CPVC  

surfaces. A chemical cleaner such as MEK may be used.

ceMent

The cement should be a bodied cement of approximately 500 to 

1600 centipoise viscosity containing 10-20% (by weight) virgin PVC 

material  solvated  with  tetrahydrofuran  (THF).  Small  quantities  of 

dimethyl formamide (DMF) may be included to act as a retarding 

agent to extend curing time.  Select the proper cement; Schedule 40 

cement should be used for Schedule 40 pipe. Never use all-purpose 

cements, commercial glues and adhesives or ABS cement to join 

PVC or CPVC pipe and fittings.

applIcators

Select a suitable pure bristle type paint brush. Use a proper width 

brush or roller to apply the primer and cement (see chart below). 

Speedy application of cement is important due to its fast drying 

characteristics.  IMPORTANT NOTE: A dauber type applicator should 

only be used on pipe sizes 2” and below. For larger diameter pipe, 

a brush or roller must be used.

recoMMended Brush* sIZe for prIMer 

and ceMent applIcatIons

   

nominal pipe  

size Brush width

   

(IPS) 

   

1.5” (3.8 cm)

   

1.5” - 2.5” (3.8 cm - 6.4 cm)

  *use onlY natural BrIstle

3

.

  MaKInG the joInt

a. cutting

  Pipe must be squarely cut to allow for the proper interfacing of the 

pipe end and the fitting socket bottom. This can be accomplished 

with a miter box saw or wheel type cutter. Wheel type cutters are 

not generally recommended for larger diameters since they tend 

to flare the corner of the pipe end. If this type of cutter is used, 

the flare on the end must be completely removed.

NOTE: Power saws should be specifically designed to cut plastic pipe.

step a

Summary of Contents for SHE 50 76N

Page 1: ...L AND WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOU ARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEA...

Page 2: ...alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage WARNING CAUTION CAUTION DANGER All safety messages will generally tell you about the type...

Page 3: ...3 GENERAL SAFETY INFORMATION...

Page 4: ...4 GENERAL SAFETY INFORMATION at least 18 45 7cm above the floor This will reduce but not eliminate the risk...

Page 5: ...ilablefromNational Fire Protection Association 1 Batterymarch Park Quincy MA 02269 3 The water heater when installed must be grounded in accordance with the local codes or in the absence of local code...

Page 6: ...feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch...

Page 7: ...Exhaust Tee GG Elbow GET TO KNOW YOUR WATER HEATER GAS MODELS A Vent Pipe B Anode C Hot Water Outlet D Outlet 120 VAC F Gas Supply G Main Manual Gas Shut Off Valve H Ground Joint Union J Dirt Leg K O...

Page 8: ...8 TYPICAL INSTALLATION CONDENSATE HOSE AND DRAIN PAN FIGURE 1 continued...

Page 9: ...ship for normal adult skin If anyone using hot water provided by the water heater being installed fits into one of these groups or if there is a local code or state law requiring a certain water tempe...

Page 10: ...cs All models Maximum Supply Pressure 14 inches W C 3 48kPa Minimum Supply Pressure Natural Gas 5 0 inches W C 1 24kPa Minimum Pressure must be maintained under both load and no load static and dynami...

Page 11: ...talled in locations where leakage may result in property damage even with the use of a drain pan piped to a drain However unanticipated damage can be reduced or prevented by a leak detector or water s...

Page 12: ...rine based chemicals refrigerants etc in addition to being highly flammable in many cases will also react to form corrosive hydrochloric acid when exposed to the combustion products of the water heate...

Page 13: ...e the size of openings providing fresh air into confined spaces EXHAUST FANS Where exhaust fans are installed additional air shall be provided to replace the exhausted air When an exhaust fan is insta...

Page 14: ...a reference for the openings that provide fresh air into confined spaces only Do not refer to these illustrations for the purpose of vent installation See Installation of Vent System on pages 20 21 fo...

Page 15: ...f code requirements or such conditions as high line pressure among others have installed devices such as pressure reducing valves check valves and back flow preventers Devices such as these cause the...

Page 16: ...the T P valve Secure all insulation using tape Temperature Pressure Relief Valve Explosion Hazard Temperature Pressure Relief Valve must comply with ANSI Z21 22 CSA 4 4 and ASME code Properly sized T...

Page 17: ...T P valve is not intended for the constant relief of thermal expansion Aproperly sized thermal expansion tank must be installed on all closed systems to control thermal expansion see Closed Water Syst...

Page 18: ...system by closing itsindividualmanualShut offvalveduringanypressuretestingofthegas supply piping system at test pressures equal to or less than 1 2 pound per square inch 3 5 kPa Connecting gas piping...

Page 19: ...uctions Assemble Vent Pipe Assemblies 1 2 and 3 See Figure 1 prior to cementing The preferred orientation of Vent Pipe Assembly 1 Condensate U Assembly is shown in Figure 16 However this assembly may...

Page 20: ...0 cm 12 inches 30 cm K Clearance to a mechanical air supply inlet 6 feet 1 83 m 3 feet 91 cm above if within 10 feet 3 m horizontally E Clearance to unventilated soffit 12 inches 30 cm 12 inches 30 cm...

Page 21: ...ectmaterialasdetailedabovehasbeenused andthatminimum ormaximumventlengthsandterminallocationasdetailedinthismanual have been met Carefully inspect entire venting system for any signs of cracks or frac...

Page 22: ...that the plastic tubing is still attached from the air pressure switch to the port on the blower housing Make sure the plastic tubing is not folded anywhere between the pressure switch and the blower...

Page 23: ...ine This will allow the vent to easily slide through the opening The resulting gap will be covered up by the Vent Terminal cover plate Repeat this step on inside wall if necessary SEQUENCE OF INSTALLA...

Page 24: ...ighest anticipated snow level install a snorkel as shown in bottom portion of Figure 20 NOTE With the installation of a snorkel it is necessary to use two 90 elbows that shall be considered along with...

Page 25: ...cement not included with kit and glue the two inch PVC pipe coming from the blower into the VAA 3 Perform the same sequence on the PVC pipe coming from the exhaust side vent terminal side of the VAA...

Page 26: ...and the vent pipe system Air leaks will allow flue gas by products to disseminate into the room creating an unsafe environment and could cause illness asphyxiation and or even death FIGURE 24 Typical...

Page 27: ...and above PRIMER It is recommended that Tetrahydrofuran THF be used to prepare the surfaces of pipe and fittings for solvent welding Do not use water rags gasoline or any other substitutes for cleanin...

Page 28: ...make a second mark as the primer and cement will most likely destroy your first one Apply primer to the surface of the pipe and fitting socket with a natural bristle brush This process softens and pr...

Page 29: ...R buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Turn off all ele...

Page 30: ...c does not have access If a suitable area is not available a cover should be installed over the thermostat to prevent tampering Thewatertemperaturesettingwasfactorysetatthelowesttemperature Pressing t...

Page 31: ...cal water heater supplier or service agency for further information concerning an Anode Replacement Kit and this chlorination treatment If the smelly water persists after the anode replacement and chl...

Page 32: ...uld be made of the main burner and the hot surface igniter assembly for proper flame characteristics and ignition sequences This can be done by removing the Outer Door and viewing the main burner oper...

Page 33: ...ve a thermal expansion tank installed is not covered under the limited warranty Thermal expansion tanks must be installed on all closed water systems DO NOT PLUG THE TEMPERATURE PRESSURE RELIEF VALVE...

Page 34: ...ose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances wat...

Page 35: ...control does not energize the blower replace the Intelli Vent control If the blower fails to Blower may run continuously in start when energized replace the blower assembly this condition 2 Ensure the...

Page 36: ...ff for 10 20 seconds then on again to clear this error code 4 Ensure the flame sensor is clean use ultra fine steel wool or Scotch Brite pad to clean flame sensor 5 Ensure the hot surface ignitor is p...

Page 37: ...in tolerance 1 Ensure air pressure switch hose is not kinked or clogged ensure the blower housing is clear of any condensation 2 Check vent temperature limit switch if it is determined that the vent t...

Page 38: ...38 These guidelines should be utilized by a qualified service agent TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES...

Page 39: ...installed at the heater s and operational at all times The relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES Under the limited warranty the warrantor will...

Page 40: ...www statewaterheaters com 500 Tennessee Waltz Parkway Ashland City TN 37015 Technical Support 800 365 0024 Parts 800 821 2017...

Reviews: