8.2
Fault table for general faults
Table 8.1
General faults Page 1 of 2
Characteristic
Cause
Measure
Observation
Gas smell
Gas leak
Warning
Immediately close the main gas valve.
Warning
Do not operate any switches.
Warning
No naked flames.
Warning
Ventilate the room where the appliance is located.
n
Remark
Immediately contact your installer or local gas company.
Water leak
Leak from one of the
water connections
(screw thread).
Tighten the screw thread connection.
If the leak is not resolved, consult your installer.
Leak from another
water appliance or
pipe nearby.
Trace the leak.
Leak from the
appliance's tank.
Consult the supplier and/or manufacturer.
Condensation
When draining (excessive) tap water, wait until the water in the
waterheater has reached the set temperature.